Zobrazeno 1 - 10
of 37
pro vyhledávání: '"H A C Jacob"'
Publikováno v:
Zeitschrift für Orthopädie und ihre Grenzgebiete. 128:282-288
A photogrammetric method was used to measure the range of motion of the iliosacral joint in a two-dimensional in-vitro model. The results were compared with values reported in the literature. The influence of morphological and histopathological param
Autor:
H. A. C. Jacob, B. Hilfiker
Publikováno v:
Zeitschrift für Orthopädie und ihre Grenzgebiete. 128:254-261
In March, 1981, development of a hip socket for implantation without the use of bone cement was begun in the Biomechanics Research Laboratory of the Department of Orthopaedic Surgery of the University of Zurich, Balgrist. Already in March, 1982, the
Publikováno v:
Zeitschrift für Orthopädie und ihre Grenzgebiete. 134:177-184
The stiffness of the AO external pedicular fixator was analysed in an experimental laboratory study using three different sets of pedicle screws and different configurations of the implant. The experiments were performed with a wooden model as well a
Publikováno v:
Zeitschrift für Orthopädie und ihre Grenzgebiete. 121:555-563
In the last few years, the operative treatment of severe spondylolisthesis has aimed to reduce the gliding movement between the vertebral bodies proceeding then to a spondylodesis. So far, various questions have remained open. When, with which techni
Publikováno v:
Zeitschrift für Orthopädie und ihre Grenzgebiete. 122:62-68
An der Orthopadischen Universitatsklinik Balgrist in Zurich sind zwischen Juli 1976 und Ende 1979 bei 37 Patienten 43 Double-Cup-Huftarthroplastiken nach Freeman eingesetzt worden. Bei der Kontrolle, 4-7 Jahre nach Implantation, werden 15% Fruhkompli
Autor:
H. H. Wetz, H. A. C. Jacob
Publikováno v:
Zeitschrift für Orthopädie und ihre Grenzgebiete. 132:244-249
Stance- and swing-phase control of AK prostheses due to the development of new knee joint mechanics has been frequently discussed in the recent past. The functional anatomical principles of the thigh muscles will be presented, including the results o
Autor:
K. F. Afifi, H. A. C. Jacob
Publikováno v:
Zeitschrift für Orthopädie und ihre Grenzgebiete. 119:157-162
An estimation of wear was carried out on 100 of 340 UHMW polyethylene sockets (RCH 1000) that were implanted with Protasul-10 prostheses furnished with a chromium plated head. This was effected by measuring the position of the head relative to the so
Autor:
A. Schreiber, H. A. C. Jacob
Publikováno v:
Zeitschrift für Orthopädie und ihre Grenzgebiete. 123:803-807
The arthrodised hip of a 52 year-old female patient that had been absolutely trouble free for 9 years was remobilised by implanting a Mittelmeier, Autophor prosthesis (Al2O3 socket, Al2O3 head). Two years later, the hip joint had to be revised becaus
Autor:
H. A. C. Jacob, A. H. Huggler
Publikováno v:
Zeitschrift für Orthopädie und ihre Grenzgebiete. 121:44-46