Autor:
Guy M. Besson
Publikováno v:
Medical Physics. 26:415-426
Third generation fan-beam computerized tomography(CT) scanners acquire data one entire projection at a time. The associated filtered-backprojection algorithm requires a computationally expensive pixel-dependent weight factor in the backprojector. Met
Autor:
Kenneth E. Crocker, Guy M. Besson
Publikováno v:
SPIE Proceedings.
This paper describes a system for multi-spectral single-scan lung imaging. The proposed approach relies on a low noise detector sampled at a high rate. The proposed method overcomes limitations of CCD time-and-delay integration slot-scanning systems.
Autor:
Mike Tesic, Bernard Munier, Pascal Prieur-Drevron, Roland Sottoriva, Emmanuel Calais, Guy M. Besson, Paul DeGroot, Andreas Koch
Publikováno v:
SPIE Proceedings.
The FDA has approved the SenoScan slot-scanning Full-field Digital Mammography system. A high power Tungsten-target x- ray tube enables breast imaging with 0.22 s effective exposure time. A 21-cm X 29-cm area is scanned in less than 6 seconds, at a t
Publikováno v:
Medical physics. 27(5)
This paper presents a calibration and correction method for detectorcell gain variations. A key functionality of current CTscanners is to offer variable slice thickness to the user. To provide this capability in multislice volumetric scanners, while
Autor:
Guy M. Besson
Publikováno v:
SPIE Proceedings.
This paper introduces a new multislice helical weighting method. When used in conjunction with rebining from fan-beam to parallel projections, this approach leads to a single- filtering algorithm, that is, each projection needs to be filtered only on
Publikováno v:
Medical Imaging 1999: Physics of Medical Imaging.
This paper presents a calibration and correction method for detector cell gain variations. To provide variable slice thickness capability in multislice volumetric scanners, while minimizing costs, it is necessary to combine the signals from several d
Publikováno v:
Medical Imaging 1999: Physics of Medical Imaging.
This paper presents a modification of the z-slope algorithm introduced in the accompanying paper 'An algorithm to correct for z-detector gain variations in multislice volumetric CT.' The x-expansion coefficients found by SVD are plugged into the equa
Autor:
Guy M. Besson
Publikováno v:
Medical Imaging: Image Processing
In this paper, a straightforward method of estimating the CT projections is applied to simplified pre-processing, simplified reconstruction filtering, and to low-dose and local CT image reconstruction. The method relies on the projection- to-projecti
Autor:
Guy M. Besson
Publikováno v:
SPIE Proceedings.
The focus of this paper is on CT helical weighting algorithms using one source rotation, or 2 pi, worth of projection data. Currently known 2 pi helical weighting algorithms include a fan-angle dependency, and do not lend themselves to fast reconstru
Autor:
Guy M. Besson
Publikováno v:
Medical Imaging: Image Processing
A detection-estintation method is introduced for use in digital subtraction angiography (DSA) . The method allows three dimensional (3-D) reconstruction of the vasculature by an image intensifier-based volume irnager using few subtracted projections.