Zobrazeno 1 - 10
of 131
pro vyhledávání: '"Guillaume Renaud"'
Publikováno v:
Photoacoustics, Vol 38, Iss , Pp 100602- (2024)
We present a technique called photoacoustic vector-flow (PAVF) to quantify the speed and direction of flowing optical absorbers at each pixel from acoustic-resolution PA images. By varying the receiving angle at each pixel in post-processing, we obta
Externí odkaz:
https://doaj.org/article/341ec687828844d99331424dbd560af3
Autor:
Laëtitia Belgodère, Joseph Emmerich, Nicolas Albin, Trystan Bacon, Pascale Daynes, Stéphane Vignot, Thierry Vial, Guillaume Renaud, Carole Le Saulnier, Corine Maillard-Couvreur, Mélanie Cachet, Marie-Laure Veyries, Rym Youdarene, Wahiba Oualikene-Gonin, Christelle Ratignier-Carbonneil, Patrick Maison
Publikováno v:
Frontiers in Public Health, Vol 11 (2023)
Shortages of drugs and medical devices have tended to increase in France and worldwide, with consequences for patients and healthcare professionals. Preventing shortages of health products has become a priority for regulatory authorities, including t
Externí odkaz:
https://doaj.org/article/a9ff1c470a374598b3b60fd4f8e1cb47
Publikováno v:
Composites Part C: Open Access, Vol 12, Iss , Pp 100401- (2023)
Damage modelling of composite material delamination is an intense field of research to understand the complex composite failure behaviour and predict the residual strength of damaged structures. One of the widely employed methods to simulate delamina
Externí odkaz:
https://doaj.org/article/9908b377faea417a95286ab1a8cd8753
Publikováno v:
JBMR Plus, Vol 5, Iss 11, Pp n/a-n/a (2021)
ABSTRACT Intraosseous blood circulation is thought to have a critical role in bone growth and remodeling, fracture healing, and bone disorders. However, it is rarely considered in clinical practice because of the absence of a suitable noninvasive in
Externí odkaz:
https://doaj.org/article/0671c161687d469cbcdad18f2df16bc6
Publikováno v:
Applied Sciences, Vol 12, Iss 19, p 10183 (2022)
While transcranial ultrasound imaging is a promising diagnostic modality, it is still hindered due to phase aberration and multiple scattering caused by the skull. In this paper, we compare near-field phase-screen modeling (PS) to a geometry-based ph
Externí odkaz:
https://doaj.org/article/c0930bbd40614f2eaa8a19a4c5588206
Publikováno v:
Physical Review X, Vol 8, Iss 4, p 041002 (2018)
The basic physics of sound waves enables ultrasound to visualize biological tissues with high spatial and temporal resolution. Recently, this capability was enhanced with the development of acoustic biomolecules—proteins with physical properties en
Externí odkaz:
https://doaj.org/article/71c40b00c86348dab075f6926b10d29d
Autor:
Julien Ochala, Guillaume Renaud, Monica Llano Diez, Varuna C Banduseela, Sudhakar Aare, Karsten Ahlbeck, Peter J Radell, Lars I Eriksson, Lars Larsson
Publikováno v:
PLoS ONE, Vol 6, Iss 6, p e20558 (2011)
In critically ill patients, mechanisms underlying diaphragm muscle remodeling and resultant dysfunction contributing to weaning failure remain unclear. Ventilator-induced modifications as well as sepsis and administration of pharmacological agents su
Externí odkaz:
https://doaj.org/article/1c30db448b66402697f4458d015a287a
Autor:
Moein Mozaffarzadeh, Dirk J. Eric Verschuur, Martin D. Verweij, Nico de Jong, Guillaume Renaud
Publikováno v:
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control, 69(9), 2599-2610. Institute of Electrical and Electronics Engineers Inc.
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 69(9)
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 69(9)
In a recent study, we proposed a technique to correct aberration caused by the skull and reconstruct a transcranial B-mode image with a refraction-corrected synthetic aperture imaging (SAI) scheme. Given a sound speed map, the arrival times were calc
Autor:
Sander Spiekhout, Jason Voorneveld, Benjamin van Elburg, Guillaume Renaud, Tim Segers, Guillaume P. R. Lajoinie, Michel Versluis, Martin D. Verweij, Nico de Jong, Johannes G. Bosch
Publikováno v:
The Journal of the Acoustical Society of America, 151(6)
Journal of the Acoustical Society of America, 151(6):3993, 3993-4003. American Institute of Physics
Journal of the Acoustical Society of America, 151(6), 3993-4003. Acoustical Society of America
Journal of the Acoustical Society of America, 151(6):3993, 3993-4003. American Institute of Physics
Journal of the Acoustical Society of America, 151(6), 3993-4003. Acoustical Society of America
Ultrasound (US) contrast agents consist of microbubbles ranging from 1 to 10 μm in size. The acoustical response of individual microbubbles can be studied with high-frame-rate optics or an “acoustical camera” (AC). The AC measures the relative m
Publikováno v:
NDE 4.0, Predictive Maintenance, Communication, and Energy Systems: The Digital Transformation of NDE.