Zobrazeno 1 - 5
of 5
pro vyhledávání: '"Guiguo Ge"'
Autor:
Meng He, Xi Chen, Jie Fang, Qunfeng Chen, Huanyao Sun, Yibo Wang, Jiaqi Zhong, Lin Zhou, Chuan He, Jinting Li, Danfang Zhang, Guiguo Ge, Wenzhang Wang, Yang Zhou, Xiao Li, Xiaowei Zhang, Lei Qin, Zhiyong Chen, Rundong Xu, Yan Wang, Zongyuan Xiong, Junjie Jiang, Zhendi Cai, Kuo Li, Guo Zheng, Weihua Peng, Jin Wang, Mingsheng Zhan
Publikováno v:
npj Microgravity, Vol 9, Iss 1, Pp 1-10 (2023)
Abstract The precision of the weak equivalence principle (WEP) test using atom interferometers (AIs) is expected to be extremely high in microgravity environment. The microgravity scientific laboratory cabinet (MSLC) in the China Space Station (CSS)
Externí odkaz:
https://doaj.org/article/8c410daeb6844022b7143fca7a591bbc
Autor:
Yang Zhou, Wenzhang Wang, Guiguo Ge, Jinting Li, Danfang Zhang, Meng He, Biao Tang, Jiaqi Zhong, Lin Zhou, Runbing Li, Ning Mao, Hao Che, Leiyuan Qian, Yang Li, Fangjun Qin, Jie Fang, Xi Chen, Jin Wang, Mingsheng Zhan
Publikováno v:
Sensors, Vol 24, Iss 3, p 1016 (2024)
A dynamic gravimeter with an atomic interferometer (AI) can perform absolute gravity measurements with high precision. AI-based dynamic gravity measurement is a type of joint measurement that uses an AI sensor and a classical accelerometer. The coupl
Externí odkaz:
https://doaj.org/article/1d080cf12e85425bba3d3051a0704d35
Autor:
Guiguo Ge, Xi Chen, Jinting Li, Danfang Zhang, Meng He, Wenzhang Wang, Yang Zhou, Jiaqi Zhong, Biao Tang, Jie Fang, Jin Wang, Mingsheng Zhan
Publikováno v:
Sensors, Vol 23, Iss 13, p 6115 (2023)
We design and implement a compact 85Rb atom gravimeter (AG). The diameter of the sensor head is 35 cm and the height is 65 cm; the optical and electronic systems are installed in four standard 3U cabinets. The measurement accuracy of this AG is impro
Externí odkaz:
https://doaj.org/article/c44780c278fd476db6fb360d8ed0449e
Autor:
Zhan, Guiguo Ge, Xi Chen, Jinting Li, Danfang Zhang, Meng He, Wenzhang Wang, Yang Zhou, Jiaqi Zhong, Biao Tang, Jie Fang, Jin Wang, Mingsheng
Publikováno v:
Sensors; Volume 23; Issue 13; Pages: 6115
We design and implement a compact 85Rb atom gravimeter (AG). The diameter of the sensor head is 35 cm and the height is 65 cm; the optical and electronic systems are installed in four standard 3U cabinets. The measurement accuracy of this AG is impro
Autor:
Xi Chen, Meng He, Jinting Li, Danfang Zhang, Jie Fang, Guiguo Ge, Wenzhang Wang, Yang Zhou, Chuan He, Lin Zhou, Yibo Wang, Xiao Li, Rundong Xu, Zongyuan Xiong, Xiaowei Zhang, Jiaqi Zhong, Qunfeng Chen, Huanyao Sun, Qin Lei, Zhiyong Chen, Kuo Li, Guo Zheng, Weihua Peng, Jin Wang, Mingsheng Zhan, yan Wang, Zhendi Cai, Junjie Jiang
The precision of the weak equivalence principle (WEP) test using atom interferometers (AIs) is expected to be extremely high in microgravity environment. The microgravity scientific laboratory cabinet (MSLC) in the China Space Station (CSS) can provi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::88297b383bbaf654d019393e3e723913
http://arxiv.org/abs/2306.04097
http://arxiv.org/abs/2306.04097