The International Journal of Artificial Organs. 46:215-225
Background: Cardiac functions and support modes of left ventricular assist device (LVAD) will influence the pump inner flow field and blood damage potential. Methods: Computational fluid dynamics (CFD) method and lumped-parameter-model (LPM) were app
Autor:
Xingmin Gui, Chen Haibo, Shengshou Hu, Hansong Sun, Yan Zhang, Dong-Hai Jin, Zhou Jianye, Guangmao Liu
Publikováno v:
ASAIO Journal. 65:59-69
The gaps between the blades and the shroud (or hub) of an axial blood pump affect the hydraulics, efficiency, and hemolytic performance. These gaps are critical parameters when a blood pump is manufactured. To evaluate the influence of blade gaps on
Publikováno v:
Medical Science Monitor : International Medical Journal of Experimental and Clinical Research
BACKGROUND Cannula shape and connection style influence the risk of thrombus formation in the blood pump by varying the blood flow characteristics inside the pump. Inlet cannulas should be designed based on the need for anatomical fit and reducing th
Publikováno v:
Analytical chemistry. 91(18)
The ratiometric method allows the measurement of ratio changes between two signals, which can reduce the detection signal fluctuations caused by distinct background conditions and greatly improve the reproducibility and reliability of detection. Howe
Publikováno v:
Volume 3B: Fluid Applications and Systems.
The axial blood pump body primarily contains the Inlet Guide Vane (IGV), Rotor Impeller (RI), Outlet Guide Vane (OGV) and pump casing. There must be gaps between rotor blade tip and pump casing or between OGV blade root and rotor hub for the impeller
Autor:
Guangmao, Liu, Jian, Xi, Haibo, Chen, Yan, Zhang, Jianfeng, Hou, Jianye, Zhou, Hansong, Sun, Shengshou, Hu
Publikováno v:
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi
An implantable axial blood pump was designed according to the circulation assist requirement of severe heart failure patients of China. The design point was chosen at 3 L/min flow rate with 100 mm Hg pressure rise when the blood pump can provide flow
Autor:
Guangmao, Liu, Jianye, Zhou, Shengshou, Hu, Hansong, Sun, Haibo, Chen, Yan, Zhang, Fuliang, Luo
Publikováno v:
Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi. 30(1)
The tip structure is one of the key factors to determine the performance of left ventricular assist device (LVAD) inflow cannulas. The tip structure influences the thrombosis, hemolysis in cannula and left ventricle and suction leading to obstruction
Publikováno v:
Medical Science Monitor; 2017, Vol. 23, p1655-1661, 7p, 6 Color Photographs