Zobrazeno 1 - 10
of 34
pro vyhledávání: '"Grzegorz Soza"'
Autor:
Andreas Wimmer, Ramona Woitek, Stefan Hajdu, Daniel Toth, Helmut Prosch, Grzegorz Soza, Thomas Mang, Ulrika Asenbaum, Csilla Balassy, Mathias Lazar, Michael Weber, Michael Töpker, Helmut Ringl
Publikováno v:
European Radiology. 25:1865-1874
To assess a radiologist’s detection rate of rib fractures in trauma CT when reading curved planar reformats (CPRs) of the ribs compared to reading standard MPRs. Two hundred and twenty trauma CTs (146 males, 74 females) were retrospectively subject
Autor:
Michael Suehling, Grzegorz Soza, Christian Tietjen, Marc Stamminger, Bernhard Preim, Jan Kretschmer
Publikováno v:
IEEE Transactions on Visualization and Computer Graphics. 20:2496-2505
Dedicated visualization methods are among the most important tools of modern computer-aided medical applications. Reformation methods such as Multiplanar Reformation or Curved Planar Reformation have evolved as useful tools that facilitate diagnostic
Autor:
Nancy A. Obuchowski, Emilio Vega, Gregory V. Goldmacher, Maria Athelogou, Hitoshi Yamagata, Rudresh Jarecha, Binsheng Zhao, Guillaume Orieux, Michael C. Bloom, Ninad Mantri, Luduan Zhang, Hyun J. Kim, Marios A. Gavrielides, Grzegorz Soza, Osama Masoud, Dirk Colditz Colditz, Yuhua Gu, Hubert Beaumont, Andrew J. Buckler, Ganesh Saiprasad, Jan Martin Kuhnigk, Adele P. Peskin, Robert J. Gillies, Jan Hendrik Moltz, Sam Peterson, Alden A. Dima, Nicholas Petrick, Estanislao Oubel, Tomoyuki Takeguchi, Yongqiang Tan, Christian Tietjen
Rationale and Objectives Quantifying changes in lung tumor volume is important for diagnosis, therapy planning, and evaluation of response to therapy. The aim of this study was to assess the performance of multiple algorithms on a reference data set.
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::580ae9e28128401318397f70151bdaa5
https://publica.fraunhofer.de/handle/publica/248173
https://publica.fraunhofer.de/handle/publica/248173
Autor:
Grzegorz Soza, Roberto Grosso, Christopher Nimsky, Peter Hastreiter, Günther Greiner, Ulf Labsik, Rudolf Fahlbusch
Publikováno v:
Computer Aided Surgery. 8:241-246
In this paper we introduce a finite element-based strategy for simulation of brain deformation occurring during neurosurgery. The phenomenon, known as brain shift, causes a decrease in the accuracy of neuronavigation systems that rely on preoperative
Publikováno v:
Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention. 17(Pt 1)
In this paper, we present the idea of equipping a tomographic medical scanner with a range imaging device (e.g. a 3D camera) to improve the current scanning workflow. A novel technical approach is proposed to robustly estimate patient surface geometr
Publikováno v:
Medical Image Computing and Computer-Assisted Intervention – MICCAI 2014 ISBN: 9783319104034
MICCAI (1)
MICCAI (1)
In this paper, we present the idea of equipping a tomographic medical scanner with a range imaging device (e.g. a 3D camera) to improve the current scanning workflow. A novel technical approach is proposed to robustly estimate patient surface geometr
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::d86fc4123b81cbee59d709e5da285de2
https://doi.org/10.1007/978-3-319-10404-1_59
https://doi.org/10.1007/978-3-319-10404-1_59
Publikováno v:
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren. 184
Autor:
Sandra Freitag-Wolf, S. Fischer, Grzegorz Soza, M. Fabel, A Wulff, Hendrik Bolte, Jürgen Biederer, Martin Heller, Christian Tietjen
Publikováno v:
RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 184(9)
To investigate measurement accuracy in terms of precision and inter-rater variability in the simultaneous volumetric assessment of lung, liver and lymph node metastasis size change over time in comparison to RECIST 1.1.Three independent readers evalu