Publikováno v:
Archives of Civil Engineering, Vol vol. 69, Iss No 3 (2023)
Eurocode standard recommends using fundamental basic wind velocity (characteristic velocity) as the design value in civil engineering. There are different approaches to estimate this value depending on the climate features of the given area and the q
Externí odkaz:
https://doaj.org/article/77e3d049b7614027a8ace6314ec33916
Autor:
Grzegorz Kimbar
Publikováno v:
Budownictwo i Architektura, Vol 12, Iss 2 (2013)
The paper summarizes the problem of snow load prediction on building roofs, the importance of wind action in context of this load and the scope of wind tunnel applications in such research with more detailed description of experimental stand in Craco
Externí odkaz:
https://doaj.org/article/65945086d7994d5986836cee22bd46a7
Autor:
Marta Kadela, Florentyna Copiak, Robert Geryło, Tomasz Godlewski, Grzegorz Kimbar, Mateusz Kozicki, Beata Łoboda, Katarzyna Strycharz
Publikováno v:
MATERIAŁY BUDOWLANE. 1:35-41
Publikováno v:
Fire Safety Journal. 136:103760
A moderate-sized (8 MW) fire was modeled in a warehouse located in an urban area with diverse architecture, under wind conditions. The study investigates the impact of neighboring architecture on the wind field and the resulting effect on smoke contr
Publikováno v:
Fire Technology. 57:3101-3123
The paper is focused on the topic of smoke control in a confined, underground cellar area of a historical building, that is undergoing conversion to a restaurant. Similar venues were host to some of the most devastating fires in history. We have inve
Publikováno v:
Open Engineering, Vol 8, Iss 1, Pp 147-155 (2018)
Arguably, one of the most important requirement a building have to meet in case of fire is to ensure the safe evacuation of its users and the work of rescue teams. Consequently, issues related to the risks associated with falling parts of facades are
Publikováno v:
MATERIAŁY BUDOWLANE. 1:25-30
Autor:
Grzegorz Kimbar, Paweł Roszkowski
Publikováno v:
Fire Safety Journal. 120:103123
Full-scale external fire test of a 92 m³ steel silo carried out in 2018 was the first such attempt to determine the effect of the fire on a free-standing silo. So far, the research conducted in this area focused mainly on the risk of explosion and i
Publikováno v:
AIP Conference Proceedings.
This paper is a proposal of a new device that may be used as a component of natural smoke ventilation systems – an external aerodynamic baffle used to limit the wind effect at the most adverse angle. Natural ventilation is not only affected by the