Zobrazeno 1 - 10
of 50
pro vyhledávání: '"Graham J Chapman"'
Publikováno v:
BMJ Open, Vol 14, Iss 4 (2024)
Introduction Custom insoles are a routine treatment for many foot pathologies, and the use of computer-aided design and computer-aided manufacturing (CAD/CAM) is well established within clinical practice in the UK. The method of foot shape capture us
Externí odkaz:
https://doaj.org/article/28fc5a39422f4e49a4a86f17896b9351
Autor:
David Stephensen, Anthony Redmond, Michael Richards, Rebecca Walwyn, Ben Palmer, Heidi Siddle, Richard A Wilkins, Martin J Scott, Hua Xiang, Elizabeth Horn, Graham J Chapman
Publikováno v:
BMJ Open, Vol 12, Iss 1 (2022)
Externí odkaz:
https://doaj.org/article/6fb416e9a68c4ac78a1f4f551604b889
Publikováno v:
Journal of Foot and Ankle Research, Vol 7, Iss S1, Pp n/a-n/a (2014)
Externí odkaz:
https://doaj.org/article/0d396809d48e4b50b5ad0287f06c47a3
Publikováno v:
Journal of Foot and Ankle Research, Vol 15, Iss 1, Pp n/a-n/a (2022)
Abstract Background Different multi‐segment foot models have been used to explore the effect of foot orthoses. Previous studies have compared the kinematic output of different multi‐segment foot models, however, no study has explored if different
Externí odkaz:
https://doaj.org/article/0ffa6627119b4d5f88bdc31a180a014f
Autor:
Richard A. Wilkins, Heidi J. Siddle, Graham J. Chapman, Elizabeth Horn, Rebecca Walwyn, Anthony C. Redmond
Publikováno v:
Haemophilia. 29:600-607
Moderate haemophilia has traditionally been associated with less complications than severe haemophilia. Changes in treatment recommendations have highlighted the burden of moderate haemophilia with a subset of patients with a severe bleeding phenotyp
Autor:
Richard A. Wilkins, Heidi J. Siddle, Graham J. Chapman, Elizabeth Horn, Rebecca Walwyn, Anthony C. Redmond
Publikováno v:
Journal of Foot and Ankle Research. 16
Background Haemophilia is an X-linked recessive genetic disorder characterised by bleeding within soft tissue and joints. The ankle is disproportionally affected by haemarthropathy when compared to the elbows and knees; reported as the most affected
Autor:
Lefan Wang, Dominic Jones, Alexander Jones, Graham J. Chapman, Heidi J. Siddle, David Russell, Ali Alazmani, Peter R. Culmer
Publikováno v:
IEEE Sensors Journal. 22:9104-9113
Objective: This work aims to develop an integrated in-shoe measurement system to fully record plantar loading, including both pressure and shear stresses, across the full contact surface. These data are vital to help understand and prevent the develo
Autor:
Richard A. Wilkins, Heidi J. Siddle, Graham J. Chapman, Elizabeth Horn, Rebecca Walwyn, Anthony C. Redmond
Publikováno v:
Haemophilia
Letter To The Editor
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::41bc87d53ece454f8420da09a408208e
Autor:
Daniel TSF Tadross, Graham J Chapman, Anthony C Redmond, David Macdonald, Martin Stone, David E Lunn
Background: This study investigated the effect of posterior and direct lateral (modified Hardinge) approach total hip arthroplasty on post-operative hip function compared to healthy, control participants. This study aimed to use a combination of moti
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::2347297f84c12121be8fbddd91a5c0b0
https://doi.org/10.21203/rs.3.rs-1684794/v1
https://doi.org/10.21203/rs.3.rs-1684794/v1
Autor:
Anthony C. Redmond, Morten Enemark Lund, David E. Lunn, Enrico De Pieri, Graham J. Chapman, Stephen J. Ferguson
Publikováno v:
Lunn, D E, De Pieri, E, Chapman, G J, Lund, M E, Redmond, A C & Ferguson, S J 2020, ' Current Preclinical Testing of New Hip Arthroplasty Technologies Does Not Reflect Real-World Loadings : Capturing Patient-Specific and Activity-Related Variation in Hip Contact Forces ', Journal of Arthroplasty, vol. 35, no. 3, pp. 877-885 . https://doi.org/10.1016/j.arth.2019.10.006
The Journal of Arthroplasty, 35 (3)
The Journal of Arthroplasty, 35 (3)
Background Total hip arthroplasty (THA) implants are routinely tested for their tribological performance through regulatory preclinical wear testing (eg, ISO-14242). The standardized loading conditions defined in these tests consist of simplified wav