Zobrazeno 1 - 10
of 41
pro vyhledávání: '"Gottfried, Buchhorn"'
Autor:
Stephan Frosch, Gottfried Buchhorn, Thelonius Hawellek, Tim Alexander Walde, Wolfgang Lehmann, Jan Hubert
Publikováno v:
PLoS ONE, Vol 15, Iss 12, p e0243306 (2020)
Tendon elongation after Achilles tendon (AT) repair is associated with the clinical outcome. Reliable suture techniques are essential to reduce gap formations and to allow early mobilization. Cyclic loading conditions represent the repetitive loading
Externí odkaz:
https://doaj.org/article/c23eae40d2f54c76bf6f1ac4e8131a60
Autor:
Stephan, Frosch, Gottfried, Buchhorn, Sebastian, Krohn, Wolfgang, Lehmann, Karl-Heinz, Frosch, László, Füzesi, Alice, Frosch
Publikováno v:
Histology and histopathology. 36(8)
Porous structure properties are known to conduct initial and long-term stability of titanium alloy implants. This study aims to assess the histomorphometric effect of a 3-D porosity in Ti-6Al-4V implants (PI) on osseointegration in comparison to soli
Autor:
Alice, Frosch, Sebastian, Krohn, Gottfried, Buchhorn, Wolfgang, Lehmann, Karl-Heinz, Frosch, László, Füzesi, Stephan, Frosch
Publikováno v:
Histology and histopathology. 36(7)
In the present study, we analyzed the histological characteristics of osseointegration of an open-porous Ti-6Al-4V material that was produced in a space holder method creating a 3-D through-pores trabecular design that mimics the inhomogeneity and si
Publikováno v:
Journal of the mechanical behavior of biomedical materials. 115
Porosity in titanium alloy materials improves the bony integration and mechanical properties of implants. In certain areas of application such as vertebral spacers or trabecular bone replacement (e.g. wedge augmentation in prosthetics), surface struc
Publikováno v:
Journal of Biomedical Materials Research Part B: Applied Biomaterials. 105:2326-2332
Background Osteolysis which leads to aseptic loosening of implants is a fundamental problem in joint replacement surgery (arthroplasty) and the leading cause for implant failure and revision surgery. Metal (CoCr) particles separated from implants by
Autor:
Gottfried Buchhorn, Bernd Feuerstein, Marcel Ruetschi, Christoph H. Lohmann, Gurpal Singh, Stefanie Kliche, A Drynda, Friedemann Awiszus
Publikováno v:
Journal of Biomedical Materials Research Part A. 103:1940-1948
CXCR4, the chemokine receptor for CXCL12, also known as SDF-1 (stromal cell derived factor-1), has been shown to play a pivotal role in bone metastasis, inflammatory, and autoimmune conditions but has not been investigated in periprosthetic osteolysi
Publikováno v:
Journal of Biomedical Materials Research Part B: Applied Biomaterials. 103:229-241
During the loosening cascade of cemented rough femoral stems, the destruction of the mantle and the production of cement and metal wear debris occur after the loss of constraint at the interface. Two-dimensional (2D) measurements (light microscopy ba
Autor:
Gunter Spahn, Hans-Michael Klinger, Gottfried Buchhorn, Mike H. Baums, Lars Hofmann, W. Schultz
Publikováno v:
Arthroscopy: The Journal of Arthroscopic & Related Surgery. 28:769-777
Purpose To investigate the biomechanical and magnetic resonance imaging (MRI)–derived morphologic changes between single- and double-row rotator cuff repair at different time points after fixation. Methods Eighteen mature female sheep were randomly
Publikováno v:
Open Journal of Medical Imaging. :57-63
Introduction: According to anterior spine fusion intervertebral disc spacers made of titanium or cobalt-chromium alloys are of special interest. With regard to postoperative problems implant related artifacts can lead to a decreased MRI evaluation. T
Publikováno v:
The Journal of Arthroplasty. 26:654-661
Two series of cementless total hip arthroplasty with acetabular sockets of a threaded truncated cone design were compared regarding volumetric wear rates. The first series included all-polyethylene acetabular sockets of the type Endler (E-PE); in the