Zobrazeno 1 - 10
of 82
pro vyhledávání: '"Gierich, A"'
Autor:
Andrea Spyrantis, Tirza Woebbecke, Daniel Rueß, Anne Constantinescu, Andreas Gierich, Klaus Luyken, Veerle Visser-Vandewalle, Eva Herrmann, Florian Gessler, Marcus Czabanka, Harald Treuer, Maximilian Ruge, Thomas M. Freiman
Publikováno v:
Frontiers in Neurorobotics, Vol 16 (2022)
BackgroundThe development of robotic systems has provided an alternative to frame-based stereotactic procedures. The aim of this experimental phantom study was to compare the mechanical accuracy of the Robotic Surgery Assistant (ROSA) and the Leksell
Externí odkaz:
https://doaj.org/article/ba25d518346c4d60a6d1fd06278b776a
Autor:
Alexandra Hellerbach, Klaus Luyken, Mauritius Hoevels, Andreas Gierich, Daniel Rueß, Wolfgang W. Baus, Martin Kocher, Maximilian I. Ruge, Harald Treuer
Publikováno v:
Radiation Oncology, Vol 12, Iss 1, Pp 1-9 (2017)
Abstract Background As irradiated brain volume at 12 Gy (V12) is a predictor for radionecrosis, the purpose of the study was to develop a model for Cyberknife (CK) plans that is able to predict the lowest achievable V12 at a given tumor size and pres
Externí odkaz:
https://doaj.org/article/4a1eefda251b43329d6d543afa7c4706
Autor:
Gierich, Annegret
Diss.: Phil. fak.: Wien: 1968. _ Bibliogr. p. 210-212.
Externí odkaz:
http://catalogue.bnf.fr/ark:/12148/cb351619037
Autor:
Andrea, Spyrantis, Tirza, Woebbecke, Daniel, Rueß, Anne, Constantinescu, Andreas, Gierich, Klaus, Luyken, Veerle, Visser-Vandewalle, Eva, Herrmann, Florian, Gessler, Marcus, Czabanka, Harald, Treuer, Maximilian, Ruge, Thomas M, Freiman
Publikováno v:
Frontiers in neurorobotics. 16
The development of robotic systems has provided an alternative to frame-based stereotactic procedures. The aim of this experimental phantom study was to compare the mechanical accuracy of the Robotic Surgery Assistant (ROSA) and the Leksell stereotac
Autor:
Spyrantis, A, Woebbecke, T, Rueß, D, Constantinescu, A, Gierich, A, Luyken, K, Visser-Vandewalle, V, Herrmann, E, Seifert, V, Treuer, H, Ruge, MI, Freiman, T
Publikováno v:
72. Jahrestagung der Deutschen Gesellschaft für Neurochirurgie (DGNC), Joint Meeting mit der Polnischen Gesellschaft für Neurochirurgie; 20210606-20210609; sine loco [digital]; DOCP093 /20210604/
Objective: The development of robotic systems has brought an alternative to frame-based stereotactic procedures. In this experimental setting we aim to reduce procedural errors to a minimum when comparing the ROSA robot and the Leksell stereotactic s
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0db5a837990bbfce079d5365919860fb
Autor:
Stefan Haneder, Veerle Visser-Vandewalle, Alexandra Hellerbach, David Maintz, David W. Jordan, Andreas Gierich, Nils Große Hokamp
Publikováno v:
Investigative Radiology. 53:424-431
Objectives The aim of this study was to evaluate the reduction of artifacts from deep brain stimulation electrodes (DBS) using an iterative metal artifact reduction algorithm (O-MAR), virtual monoenergetic images (VMI), and both in combination in pos
Autor:
Spyrantis, Andrea, Woebbecke, Tirza, Rueß, Daniel, Constantinescu, Anne, Gierich, Andreas, Luyken, Klaus, Visser-Vandewalle, Veerle, Herrmann, Eva, Gessler, Florian, Czabanka, Marcus, Treuer, Harald, Ruge, Maximilian, Freiman, Thomas M.
Publikováno v:
Frontiers in Neurorobotics; 3/25/2022, Vol. 16, p1-8, 8p
Autor:
Harald Treuer, Michael T. Barbe, Veerle Visser-Vandewalle, Alexandra Hellerbach, Jochen Wirths, Klaus Luyken, Till A. Dembek, Andreas Gierich, Mauritius Hoevels, Jasmin A Holz
Publikováno v:
Stereotactic and functional neurosurgery. 96(5)
Background: Directional deep brain stimulation (DBS) allows steering the stimulation in an axial direction which offers greater flexibility in programming. However, accurate anatomical visualization of the lead orientation is required for interpretin
Autor:
Mauritius Hoevels, Martin Kocher, Klaus Luyken, Wolfgang W. Baus, Maximilian I. Ruge, Alexandra Hellerbach, Andreas Gierich, Harald Treuer, Daniel Rueß
Publikováno v:
Radiation Oncology (London, England)
Radiation Oncology, Vol 12, Iss 1, Pp 1-9 (2017)
Radiation Oncology, Vol 12, Iss 1, Pp 1-9 (2017)
Background As irradiated brain volume at 12 Gy (V12) is a predictor for radionecrosis, the purpose of the study was to develop a model for Cyberknife (CK) plans that is able to predict the lowest achievable V12 at a given tumor size and prescription
Autor:
Alexander Sitz, Harald Treuer, Jochen Wirths, Mauritius Hoevels, Andreas Gierich, Klaus Luyken, Till A. Dembek, Alexandra Hellerbach, Veerle Visser-Vandewalle, Martin Klehr
Publikováno v:
Medical physics. 44(9)
Purpose Orientating the angle of directional leads for deep brain stimulation (DBS) in an axial plane introduces a new degree of freedom that is indicated by embedded anisotropic directional markers. Our aim was to develop algorithms to determine lea