Zobrazeno 1 - 10
of 11
pro vyhledávání: '"Giacomo Gervasoni"'
Autor:
Marina Cretich, Fabio Salice, Edoardo Marchisio, Chiara La Torre, Martina Scolari, Emanuele Cerquaglia, Giacomo Gervasoni, Francesco Damin, Marcella Chiari, Daniela Petti, Matteo Massetti, Parikshit Pratim Sharma, Giorgio Falduti, Marco Leone, Riccardo Bertacco, Marco Monticelli, Marco Sampietro, Edoardo Albisetti, Giorgio Ferrari
Publikováno v:
Sensors and actuators. B, Chemical
242 (2017): 280–287. doi:10.1016/j.snb.2016.11.051
info:cnr-pdr/source/autori:Sharma P.P.; Albisetti E.; Massetti M.; Scolari M.; La Torre C.; Monticelli M.; Leone M.; Damin F.; Gervasoni G.; Ferrari G.; Salice F.; Cerquaglia E.; Falduti G.; Cretich M.; Marchisio E.; Chiari M.; Sampietro M.; Petti D.; Bertacco R./titolo:Integrated platform for detecting pathogenic DNA via magnetic tunneling junction-based biosensors/doi:10.1016%2Fj.snb.2016.11.051/rivista:Sensors and actuators. B, Chemical (Print)/anno:2017/pagina_da:280/pagina_a:287/intervallo_pagine:280–287/volume:242
242 (2017): 280–287. doi:10.1016/j.snb.2016.11.051
info:cnr-pdr/source/autori:Sharma P.P.; Albisetti E.; Massetti M.; Scolari M.; La Torre C.; Monticelli M.; Leone M.; Damin F.; Gervasoni G.; Ferrari G.; Salice F.; Cerquaglia E.; Falduti G.; Cretich M.; Marchisio E.; Chiari M.; Sampietro M.; Petti D.; Bertacco R./titolo:Integrated platform for detecting pathogenic DNA via magnetic tunneling junction-based biosensors/doi:10.1016%2Fj.snb.2016.11.051/rivista:Sensors and actuators. B, Chemical (Print)/anno:2017/pagina_da:280/pagina_a:287/intervallo_pagine:280–287/volume:242
In recent years, the development of portable platforms for performing fast and point-of-care analyses has drawn considerable attention for their wide variety of applications in life science. In this framework, tools combining magnetoresistive biosens
Publikováno v:
Procedia Engineering. 168:1651-1654
A novel architecture for digital lock-in amplifiers (LIAs) able to overcome the resolution limit of standards implementations is proposed. The slow gain fluctuations of both the DAC and ADC of the generation and acquisition stages of the LIA are comp
Autor:
Pietro Baldelli, Fabio Benfenati, Daniela Petti, Parikshit Pratim Sharma, Marco Sampietro, Daniela Moretti, Edoardo Albisetti, Giacomo Gervasoni, Riccardo Bertacco, Giorgio Ferrari
Publikováno v:
Procedia Technology. 27:292-294
This work presents a platform for the detection of the neuronal magnetic signal arising from the propagation of the action potential along the axon, via an array of highly sensitive magnetoresistive sensors and a low noise front-end electronic setup.
Autor:
Erica Guerriero, Marco Sampietro, Roman Sordan, Giorgio Ferrari, Matteo Cantoni, Alessandra Manzin, Edoardo Albisetti, Daniela Petti, Andrea Mario Torti, Marco Monticelli, Marco Carminati, Giacomo Gervasoni, Riccardo Bertacco
Publikováno v:
Small. 12:921-929
Methods for the manipulation of single magnetic particles have become very interesting, in particular for in vitro biological studies. Most of these studies require an external microscope to provide the operator with feedback for controlling the part
Publikováno v:
Review of Scientific Instruments
Lock-in amplifiers (LIAs) are extensively used to perform high-resolution measurements. Ideally, when using LIAs, it would be possible to measure a minimum signal variation limited by the instrument input equivalent noise at the operating frequency a
Publikováno v:
Advanced Interfacing Techniques for Sensors ISBN: 9783319553689
Ideally, lock-in amplifiers (LIAs) would be able to measure a minimum signal variation limited by the noise of the front-end amplifier and the filtering bandwidth. On the contrary, a detailed characterization of digital LIAs shows an unforeseen 1/f n
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::fb6e14dfc6df2cfb75b1b7598167b4d2
https://doi.org/10.1007/978-3-319-55369-6_6
https://doi.org/10.1007/978-3-319-55369-6_6
Autor:
F. D'Ercoli, Anna Rocchi, Daniele Moretti, Fabio Benfenati, Daniela Petti, Parikshit Pratim Sharma, Giorgio Ferrari, Pietro Baldelli, Edoardo Albisetti, Nicola Forte, Marco Monticelli, Marco Sampietro, Giacomo Gervasoni, Riccardo Bertacco
Publikováno v:
AIP Advances, Vol 7, Iss 5, Pp 056706-056706-7 (2017)
A promising strategy to get deeper insight on brain functionalities relies on the investigation of neural activities at the cellular and sub-cellular level. In this framework, methods for recording neuron electrical activity have gained interest over
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::040ab8f56141d4f349d4bc9bf311710a
http://hdl.handle.net/11567/887879
http://hdl.handle.net/11567/887879
Publikováno v:
ICECS
Digital lock-in amplifiers are largely used to perform high-resolution measurements in different scientific fields. The experimental evidence shows that state-of-the-art, high frequency commercial models do not allow to measure signals with a resolut
The resolution of digital lock-in amplifiers working with a narrow bandwidth (
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::98dc1d7cee2c650f6a80f4e0004600f5
http://hdl.handle.net/11311/988417
http://hdl.handle.net/11311/988417
Autor:
Dario Pisignano, Giacomo Gervasoni, Enrico Prati, Giorgio Ferrari, Francesca Lezzi, Marco Sampietro, Marco Carminati, Cecilia Pennetta
Publikováno v:
2015 International Conference on Noise and Fluctuations (ICNF).
Noise measurements on high quality devices can be hampered by the unavoidable noise added by the instrument performing the measurement. The paper will briefly discuss the reduction of the instrumental noise achievable by the cross-correlation techniq