Zobrazeno 1 - 10
of 31
pro vyhledávání: '"Gerd Sulz"'
Publikováno v:
Sensors, Vol 21, Iss 19, p 6442 (2021)
Infrared attenuated total reflection (ATR) spectroscopy is a common laboratory technique for the analysis of highly absorbing liquids or solid samples. However, ATR spectroscopy is rarely found in industrial processes, where inline measurement, conti
Externí odkaz:
https://doaj.org/article/4d2fad67c91845f7bc7c079ea5b38f41
Autor:
Armin Lambrecht, Carsten Bolwien, Hendrik Fuhr, Gerd Sulz, Annett Isserstedt-Trinke, André Magi, Steffen Biermann, Jürgen Wöllenstein
Infrared attenuated total reflection (ATR) spectroscopy is a common laboratory technique for the analysis of highly absorbing liquids and solids, and a variety of ATR accessories for laboratory FTIR spectrometers are available. However, ATR spectrosc
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::aa07616a4e9f13878c6056e927e07b92
https://jsss.copernicus.org/articles/12/123/2023/
https://jsss.copernicus.org/articles/12/123/2023/
Publikováno v:
Sensors, Vol 20, Iss 10, p 2917 (2020)
Infrared attenuated total reflection (ATR) spectroscopy is a common laboratory technique for the analysis of highly absorbing liquids and solids. However, in a process environment, maintaining a sufficient sample exchange and cleaning of the sensitiv
Externí odkaz:
https://doaj.org/article/77d9e508d0a0440d8da85595f6350e12
Publikováno v:
Sensors, Vol 8, Iss 2, Pp 711-738 (2008)
Evanescent field sensors based on waveguide surfaces play an important rolewhere high sensitivity is required. Particularly tantalum pentoxide (Ta2O5) is a suitablematerial for thin-film waveguides due to its high refractive index and low attenuation
Externí odkaz:
https://doaj.org/article/86388d4fabc74aa3ab622254882bea60
Publikováno v:
Sensors (Basel, Switzerland)
Sensors
Volume 21
Issue 19
Sensors, Vol 21, Iss 6442, p 6442 (2021)
Sensors
Volume 21
Issue 19
Sensors, Vol 21, Iss 6442, p 6442 (2021)
Infrared attenuated total reflection (ATR) spectroscopy is a common laboratory technique for the analysis of highly absorbing liquids or solid samples. However, ATR spectroscopy is rarely found in industrial processes, where inline measurement, conti
Autor:
Claudia Preininger, Ursula Sauer, Albrecht Brandenburg, Erwin Schleicher, Manuel Kemmler, Birgit Koger, Gerd Sulz
Publikováno v:
Sensors and Actuators B: Chemical. 139:44-51
Objective of the study is the simultaneous measurement of three sepsis relevant parameters using a novel point-of-care system. Investigated parameters are C-reactive protein (CRP), interleukin-6 (IL-6) and procalcitonin (PCT). The format is a fluores
Autor:
Dirk Michel, Albrecht Brandenburg, Franziska Curdt, Frank Ebling, Gerd Sulz, Jörg Nestler, Kai Wunderlich
Publikováno v:
Sensors and Actuators B: Chemical. 139:245-251
A new low cost biochip readout system based on total internal reflection fluorescence (TIRF) including microfluidics is presented. The system is suitable for point-of-care diagnostics employing disposable substrates made of polymer foils producible a
Publikováno v:
Sensors and Actuators B: Chemical. 92:303-314
The detection of hybridization events on oligonucleotide microarrays in real time can be performed, using the optical principle of total internal reflection fluorescence (TIRF). We have investigated and compared three TIRF-sensing configurations usin
Autor:
Ulrich Hoefer, Klaus Steiner, Gerd Kühner, Harald Böttner, Arne Dipl Phys Dr Felske, Gerd Sulz
Publikováno v:
Sensors and Actuators B: Chemical. 44:429-433
The selectivity of SnO2 thin-film gas sensors can be modulated by changing the contact areas of the contact electrodes. The investigated SnO2 arrays have been structured with two mask steps only. Gas mixture analysis in the German threshold limit val
Publikováno v:
Sensors and Actuators B: Chemical. 22:115-119
Thin-film SnO 2 gas sensors have been structured on Si substrates. The sensors are temperature stable at 900°C in synthetic air for 48 h. No significant outdiffusion of the sensor layers can be observed after annealing. Pt catalysts lead to CO senso