Autor:
George V. Letsou, Christina M. Bolch, Erica C. Hord, William C. Altman, Boris Leschinsky, John C. Criscione
Publikováno v:
Reviews in Cardiovascular Medicine, Vol 23, Iss 6, p 211 (2022)
The CorInnova cardiac compression device (CorInnova, Inc., Houston, TX, USA) is designed to provide direct biventricular support, increase cardiac output, and improve ventricular unloading in patients with heart failure. Placed within the pericardium
Externí odkaz:
https://doaj.org/article/13a185003fa84aca93d6459da6fc8365
Stroke and mortality rates after off-pump vs. pump-assisted/no-clamp coronary artery bypass grafting
Publikováno v:
The Journal of Cardiovascular Surgery. 63
Ascending aorta manipulation during on-pump coronary artery bypass grafting (CABG) surgery can release embolic matter and may cause stroke. Strategies for lowering the stroke rate associated with coronary artery bypass grafting surgery include off-pu
Autor:
Reynolds M Delgado, O H Frazier, Faisal H. Cheema, Andrew D Lee, Fadi I Musfee, George V. Letsou
Publikováno v:
Tex Heart Inst J
We report the long-term survival of a 46-year-old man supported with a HeartMate II continuous-flow left ventricular assist device after complex repair of a bicuspid aortic valve, anomalous left main coronary artery, and dilated aorta. He has been ma
Autor:
Fadi I Musfee, randa hamden, Mrinalini Buddha, Hayden Naizer, Alexandra Q Zingg Guzman, Cecilia M Ganduglia Cazaban, George V Letsou
Publikováno v:
Circulation. 144
Introduction: The incidence of left ventricular assist device (LVAD) implantation in heart failure (HF) patients across various racial groups has not been examined in large databases. We present an analysis of racial groups and LVAD implantation usin
Autor:
George V. Letsou, Christina M. Bolch, Erica C. Hord, William C. Altman, Brad L. Youngblood, Boris Leschinsky, John C. Criscione
Publikováno v:
The Annals of thoracic surgery. 114(5)
We examined the hemodynamic effects of a new, implantable, direct cardiac assist device in an ovine heart failure model.The device, which encompasses both left and right ventricles, is inserted through the pericardial apex and self-expands to encompa
Publikováno v:
Tex Heart Inst J
Continuous-flow left ventricular assist devices have proved to be effective, durable, life-saving tools in patients with end-stage heart failure. However, because of the risks associated with mechanical circulatory support (including stroke, infectio
Autor:
Harveen K Lamba, Fadi I Musfee, Subhasis Chatterjee, Ajith P Nair, Andrew B Civitello, Leo Simpson, O H Frazier, George V Letsou
Publikováno v:
Interactive cardiovascular and thoracic surgery. 34(3)
OBJECTIVES Dialysis is considered a contraindication to continuous-flow left ventricular assist device (CF-LVAD) implantation. We evaluated clinical outcomes and survival in carefully selected, low-risk patients with renal failure who required dialys
Autor:
John C. Criscione, Boris Leschinsky, William C. Altman, Erica C. Hord, Christina M. Bolch, George V. Letsou
Publikováno v:
Reviews in Cardiovascular Medicine. 23:211
Publikováno v:
The Journal of Heart and Lung Transplantation. 40:S103-S104
Purpose Diastolic mechanical cardiac assist has been difficult to provide. We examined the hemodynamic effects of a new, implantable cardiac assist system on ovine cardiac performance. The device is inserted via the apex of the pericardium. It encomp
Publikováno v:
The Journal of Heart and Lung Transplantation. 39:S189-S190
Purpose All current short-term mechanical cardiac assist devices are placed intravascularly and are associated with relatively high rates of thrombosis and infection. We examined a non-blood-contacting extracardiac device that can be inserted with a