Zobrazeno 1 - 10
of 12
pro vyhledávání: '"Geert Cazemier"'
Single biosensor immunoassay for the detection of five aminoglycosides in reconstituted skimmed milk
Publikováno v:
Analytica Chimica Acta 488 (2003) 1
Analytica Chimica Acta, 488(1), 53-60
Analytica Chimica Acta, 488(1), 53-60
The application of an optical biosensor (Biacore 3000), with four flow channels (Fcs), in combination with a mixture of four specific antibodies resulted in a competitive inhibition biosensor immunoassay (BIA) for the simultaneous detection of the fi
Publikováno v:
Food and Agricultural Immunology, 12, 127-138
Food and Agricultural Immunology 12 (2000)
Food and Agricultural Immunology 12 (2000)
To prepare monoclonal antibodies (mAbs) against the generic part of sulfonamides, a sulfathiazole derivative was chemically linked to carrier proteins in such a way that the aromatic amino group, common to all sulfonamides, was distal to the proteins
Autor:
Monique Bienenmann-Ploum, Jolanda G du Pré, Geert Cazemier, A. Kemmers-Voncken, Willem Haasnoot, Ron Verheijen
Publikováno v:
Food and Agricultural Immunology 12 (2000)
Food and Agricultural Immunology, 12, 15-30
Food and Agricultural Immunology, 12, 15-30
Polyclonal antibodies (PAbs) against eight different sulphonamides were raised in rabbits. The aromatic amino group, common to all sulphonamides, was used for linking the different sulphonamides to the carrier proteins (bovine serum albumin (BSA) and
Publikováno v:
Analytica Chimica Acta 586 (2007) 1-2
Analytica Chimica Acta, 586(1-2), 312-318
Analytica Chimica Acta, 586(1-2), 312-318
Flumequine (Flu) is one of the fluoroquinolones most frequently applied for the treatment of broilers in The Netherlands. For the detection of residues of Flu in blood serum of broilers, a biosensor immunoassay (BIA) was developed which was fast (7.5
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::9696e81064c1c5e55cf54894a3e11d7f
https://research.wur.nl/en/publications/biosensor-immunoassay-for-flumequine-in-broiler-serum-and-muscle
https://research.wur.nl/en/publications/biosensor-immunoassay-for-flumequine-in-broiler-serum-and-muscle
Autor:
Aldert A. Bergwerff, Geert Cazemier, Rainer W. Stephany, Willem Haasnoot, Ron Verheijen, Richard Dietrich, E.E.M.G. Loomans
Publikováno v:
Food and Agricultural Immunology 14 (2002)
Food and Agricultural Immunology, 14, 15-27
Food and Agricultural Immunology, 14, 15-27
A monoclonal antibody (MAb) against dihydrostreptomycin (4G8) was developed and its performance compared with a previously developed MAb against streptomycin (4E2) in biosensor immunoassays (BIAs) using a surface plasmon resonance (SPR)-based biosens
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::97a93ee7b98ed03616a86f17d9679a10
https://research.wur.nl/en/publications/direct-versus-competitive-biosensor-immunoassays-for-the-detectio
https://research.wur.nl/en/publications/direct-versus-competitive-biosensor-immunoassays-for-the-detectio
Publikováno v:
Journal of Agricultural and Food Chemistry, 49(11), 5201-5206
Journal of Agricultural and Food Chemistry 49 (2001) 11
Journal of Agricultural and Food Chemistry 49 (2001) 11
The low prices of some nonmilk proteins make them attractive as potential adulterants in dairy products. An optical biosensor (BIACORE 3000) was used to develop a direct and combined biosensor immunoassay (BIA) for the simultaneous detection of soy,
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::fbe14ea1ec57ec23d8146980451856c6
https://research.wur.nl/en/publications/direct-biosensor-immunoassays-for-the-detection-of-nonmilk-protei
https://research.wur.nl/en/publications/direct-biosensor-immunoassays-for-the-detection-of-nonmilk-protei
Publikováno v:
The Analyst 123 (1998) 12
The Analyst, 123(12), 2437-2441
The Analyst, 123(12), 2437-2441
The one step strip test described is a competitive immunoassay in which the detector reagent consists of colloidal gold particles coated with affinity purified polyclonal anti-sulfadimidine (SDD) antibodies. The capture reagent in the assay is an SDD
Autor:
Piet Stouten, Henk J. Keukens, Jacques F. M. Nouws, Willem Haasnoot, Geert Cazemier, Arjen Lommen
Publikováno v:
The Analyst 124 (1999) 3
The Analyst, 124(3), 301-305
The Analyst, 124(3), 301-305
In 1996, the European Union established provisional maximum residue limits (MRL) for gentamicin, neomycin, streptomycin and dihydrostreptomycin in milli and tissue (0.1-5 mg kg-1). For the detection of these four aminoglycosides, three enzyme linked
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ad153301a284f57435e5602d421b6980
https://research.wur.nl/en/publications/immunochemical-detection-of-aminoglycosides-in-milk-and-kidney
https://research.wur.nl/en/publications/immunochemical-detection-of-aminoglycosides-in-milk-and-kidney
Publikováno v:
Immunoassays for Residue Analysis ISBN: 9780841233799
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::fc963477683238f7cfb8b08427228b16
https://doi.org/10.1021/bk-1996-0621.ch005
https://doi.org/10.1021/bk-1996-0621.ch005
Autor:
Jacques F. M. Nouws, Frederique Maneval, Henk J. Keukens, Willem Haasnoot, Geert Cazemier, Gary O. Korsrud
Publikováno v:
Food Additives and Contaminants 13 (1996) 7
Food Additives and Contaminants, 13(7), 811-822
Food Additives and Contaminants, 13(7), 811-822
The potential of an enzyme immunoassay (EIA) with high cross-reactivity towards the major metabolite (N4-acetyl-sulphamethazine) of sulphamethazine was tested for screening fluids and tissues. Healthy pigs were given 20 mg sulphamethazine per kg body
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::096f1313f1b17a6a5d7b105460494fcc
https://research.wur.nl/en/publications/application-of-an-enzyme-immunoassay-for-the-determination-of-sul
https://research.wur.nl/en/publications/application-of-an-enzyme-immunoassay-for-the-determination-of-sul