Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Gawoo Park"'
Publikováno v:
IEEE Open Journal of Industry Applications, Vol 5, Pp 311-324 (2024)
This article introduces a novel control approach to obtain higher grid reliability using power-to-gas (P2G) conversion systems. The proposed control method named multiparallel vector current control is a variant of virtual synchronous machine (VSM) a
Externí odkaz:
https://doaj.org/article/b3ab9b7feb3b4f03bf0cdd0db9e513ac
Publikováno v:
IEEE Access, Vol 11, Pp 42713-42724 (2023)
This paper presents an optimal grid-supporting power-to-gas (GS-P2G) control scheme that coordinates the operation of a grid-forming inverter (GFMI), battery energy storage (BES), and hydrogen energy storage (HES) in a power-to-gas (P2G) system. The
Externí odkaz:
https://doaj.org/article/877bbf92d5d54e649fd72f20e2cf6670
Publikováno v:
The Transactions of the Korean Institute of Power Electronics. 22:118-125
Publikováno v:
2019 10th International Conference on Power Electronics and ECCE Asia (ICPE 2019 - ECCE Asia).
In this paper, a design review and control algorithm of a solid state transformer (SST)model intended to replace the existing 60Hz power transformer for the railway application is presented. The proposed smart transformer is a high-frequency power el
Publikováno v:
2018 International Conference on Smart Grid (icSmartGrid).
To improve the electrical energy consumption in modern transportation systems, a 1.5 kV DC bus in the future railway application has been considered by researchers and manufacturers. One of the preferred systems for this application is a high-frequen
Publikováno v:
2008 Power Quality and Supply Reliability Conference.
This paper presents a decoupling IPD voltage control for three-phase DC/AC inverter. Though most of three-phase inverter system for UPS or stand alone renewable energy system have been analyzed by using DQ model and controlled with IPD controller. Fo
Publikováno v:
2007 7th Internatonal Conference on Power Electronics.
This paper proposes a CRA based robust digital controller for three-phase PWM VSI inverter. To regulate the inverter output voltage with constant voltage and constant frequency, the usual inverter controller consists of double looped PI controllers.
Publikováno v:
2007 European Conference on Power Electronics and Applications.
This paper proposes a robust digital controller for PWM voltage source inverter using CRA method. The usual inverter controller for the operation of constant voltage and constant frequency consists of a double looped PI controller for the outer volta
Publikováno v:
2008 Power Quality & Supply Reliability Conference; 2008, p73-78, 6p
Publikováno v:
2007 7th International Conference on Power Electronics; 2007, p164-168, 5p