Zobrazeno 1 - 10
of 94
pro vyhledávání: '"Gary Moroff"'
Publikováno v:
Transfusion. 53:651-654
BACKGROUND: On rare occasions, upon thawing of stored cryoprecipitate components, clots are observed on visual inspection. Although it has been assumed that the clot reflects fibrinogen to fibrin conversion, there are few published studies that docum
Autor:
Andrew Myrup, Gary Moroff, Dedeene Thompson-Montgomery, Stephen J. Wagner, Helen Awatefe, Shalini Seetharaman, Andrey Skripchenko, James Kurtz
Publikováno v:
Transfusion. 52:834-843
BACKGROUND: A comparative study evaluated the retention of apheresis platelet (A-PLT) in vitro properties prepared with PLT additive solution (PAS)-III or 100% plasma and stored with continuous agitation (CA) and without continuous agitation (WCA). S
Autor:
Edward C.C. Wong, Gary Moroff, Stephen J. Wagner, Yaser Diab, Valli R. Criss, Naomi L.C. Luban
Publikováno v:
Transfusion. 51:2642-2646
BACKGROUND: To facilitate volume control in neonates, platelets (PLTs) are aliquoted and stored for short periods in non–gas-permeable syringes before infusion. Although agitation of PLTs during storage in gas-permeable bags is performed to maintai
Publikováno v:
Transfusion. 51:2377-2383
BACKGROUND: pH measurements of platelet (PLT) components remain a key parameter when assessing how storage and shipping conditions influence the retention of PLT properties. Studies were conducted to characterize variations in pH measured with two pH
Autor:
W. Andrew Heaton, Constance Pickard, Stein Holme, James P. AuBuchon, Pamela Whitley, Gary Moroff
Publikováno v:
Transfusion. 51:7S-14S
BACKGROUND: The capability of holding whole blood (WB) units at ambient temperature, overnight, should help in platelet (PLT) concentrate preparation logistics. We summarize the results of a study conducted in the early 1990s that compared, in partic
Autor:
Anne F. Eder, Gary Moroff
Publikováno v:
Transfusion. 50:2288-2291
Publikováno v:
Transfusion. 51:636-642
BACKGROUND: Apheresis platelet (PLT) units are not routinely agitated during transit. Our study compared the in vitro properties of apheresis PLT units that were stored with continuous agitation (CA) and without continuous agitation (WCA) during two
Publikováno v:
Transfusion. 50:1677-1684
BACKGROUND: The Advia 120 (Siemens Diagnostics) hematology analyzer is different from other hematology analyzers in that it requires platelets (PLTs) to be “effectively spherical” to be counted. Our study evaluated how PLT counts with this hemato
Autor:
Jeffrey McCullough, Allison Hubel, Rebecca Haley, Bruce R. Lindgren, Mary C. Clay, Gary Moroff
Publikováno v:
Transfusion. 50:808-819
BACKGROUND: Cryopreservation of hematopoietic progenitor cells using liquid nitrogen and controlled-rate freezing requires complex equipment and highly trained staff and is expensive. We compared the liquid nitrogen method with methods using a combin
Publikováno v:
Transfusion. 50:1766-1777
BACKGROUND: Efforts to minimize white blood cell alloantibodies, responsible for transfusion-related acute lung injury (TRALI) in components with high-volume single-donor plasma include consideration of plateletpheresis donor screening for human leuk