Zobrazeno 1 - 10
of 51
pro vyhledávání: '"Gary A, Sod"'
Publikováno v:
Veterinary Surgery. 44:206-213
Objectives To compare the monotonic biomechanical properties of a broad 4.5 mm limited contact-dynamic compression plate (LC-DCP) fixation secured with hydroxyapatite (HA) coated cortical bone screws (HA-LC-DCP) versus uncoated cortical bone screws (
Autor:
Gary A. Sod, Renee-Claire Malenfant
Publikováno v:
Veterinary Surgery. 43:465-470
Objective To compare the 3.5 string of pearls (SOP) plate with a 3.5 mm locking compression plate (LCP) using a fracture model in static loading and cyclic fatigue testing. Study Design In vitro biomechanical testing of paired tibias with a mid-diaph
Publikováno v:
Veterinary Surgery. 40:579-585
Objectives: To compare the number of cycles to failure of 4.5 mm broad dynamic compression plates (DCP), 4.5 mm broad limited-contact dynamic compression plates (4.5-LC-DCP), and 5.5 mm broad limited-contact dynamic compression plates (5.5-LC-DCP) ha
Publikováno v:
Veterinary Surgery. 40:571-578
Objectives: To compare in vitro monotonic biomechanical properties of an axial 3-hole, 4.5 mm narrow locking compression plate (ELCP) using 5.0 mm locking screws and 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical
Publikováno v:
Veterinary Surgery. 39:833-838
Publikováno v:
Veterinary Surgery. 37:283-288
Objective— To compare monotonic biomechanical properties and fatigue life of a broad locking compression plate (LCP) fixation with a broad limited contact dynamic compression plate (LC-DCP) fixation to repair osteotomized equine third metacarpal (M
Publikováno v:
Veterinary Surgery. 36:792-799
Objectives— To compare in vitro monotonic biomechanical properties of an equine spoon plate (ESP) with an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm c
Publikováno v:
Veterinary Surgery. 35:634-642
Objectives— To compare biomechanical properties of a prototype 5.5 mm tapered shaft cortical screw (TSS) and 5.5 mm AO cortical screw for an equine third metacarpal dynamic compression plate (EM-DCP) fixation to repair osteotomized equine third met
Publikováno v:
Veterinary Surgery. 34:587-593
Objectives— To evaluate the effects of plate luting on the biomechanical properties of a broad limited contact-dynamic compression plate (LC-DCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. Study Design— In vitro biomechani
Publikováno v:
Veterinary Surgery. 34:579-586
Objectives— To compare the monotonic biomechanical properties and fatigue life of a broad, limited contact, dynamic compression plate (LC-DCP) fixation with a broad, dynamic compression plate (DCP) fixation to repair osteotomized equine 3rd metacar