Gafar Adam Ahmed, Alexander Jahnke, Markus Rickert, Bernd Ishaque, Carlos Alfonso Fonseca Ulloa, Anja Seeger
Publikováno v:
Medical Engineering & Physics. 86:122-127
The continuous improvement of minimally invasive hip endoprostheses surgery comes with a change in geometries of surgery instruments like the broach handles. Consequently, depending on the handles' curvature this results in a deviation between handle
Autor:
Marian Kampschulte, J. Bok, Gabriele A. Krombach, C.A. Fonseca Ulloa, Gafar Adam Ahmed, Christian Fölsch, Alexander Jahnke, Markus Rickert
Publikováno v:
J Orthop
Introduction Morphology and mechanic properties of impacted cancellous bone are affected by carrier substances which provide high local concentrations of antibiotics. Methods Bone chips were taken from the femoral head of 6–7 months old piglets. On
Autor:
Christian Fölsch, Alexander Jahnke, Gafar Adam Ahmed, Linda Auge, Carlos Alfonso Fonseca Ulloa, Bernd Ishaque, Jessica Loke, Markus Rickert
Publikováno v:
J Orthop
Introduction Good osteointegration of implants requires sufficient primary stability. Aim of this study was to examine the influence of screw fixation on the primary stability of press-fit cups. Methods Two press-fit acetabular cups were tested with
Autor:
Helge Hudel, Gafar Adam Ahmed, Alexander Jahnke, Carlos Alfonso Fonseca Ulloa, Mario Gernandt, Markus Rickert, Dirk Stolz
Publikováno v:
Journal of Biomechanics. 93:132-139
Following surgical Achilles tendon reconstruction surgery, there is a distinct trend towards an early and faster rehabilitation protocol to avoid muscle atrophy. However, this procedure involves the risk of a higher complication rate. In order to red
Autor:
Alexander Jahnke, Gafar Adam Ahmed, Bernd Ishaque, C.A. Fonseca Ulloa, J. Wieczorek, Markus Rickert, Jörn Bengt Seeger
Publikováno v:
J Orthop
Introduction Demographic change and demand for high quality of life lead to increasing implantation numbers. Aim of this study was to compare the Plasmafit® cup to Allofit® and Plasmacup®. Methods The study included 174 patients who had received 3
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7e30ee9d2ff331c77b844b044b0788c9
https://europepmc.org/articles/PMC7136611/
https://europepmc.org/articles/PMC7136611/
Autor:
Bernd Ishaque, Gafar Adam Ahmed, Alexander Jahnke, Markus Rickert, Cathrein Bobach, Sarah Boller, Laura Augustin
Publikováno v:
International Orthopaedics. 43:2031-2037
The purpose of this study was to check the concept of the cementless Metha® short hip stem in order to find out whether proximal physiological load transfer can be achieved. Fourty-three patients were included. Epidemiological factors were establish
Autor:
Markus Rickert, Carlos Alfonso Fonseca Ulloa, Stefan Schroeder, Bernd Ishaque, Gafar Adam Ahmed, Alexander Jahnke
Publikováno v:
Journal of Orthopaedic Research®. 36:2745-2753
Aseptic loosening is the main reason for revision of total hip arthroplasty, and relative micromotions between cementless acetabular cups and bone play an important role regarding their comparatively high loosening rate. Therefore, the aim of the pre
Autor:
Gerhard Walter Jahnke, Gafar Adam Ahmed, Markus Rickert, Alexander Jahnke, Jörn Bengt Seeger, Carlos Alfonso Fonseca Ulloa, Bernd Ishaque
Publikováno v:
Clinical Biomechanics. 52:49-56
Background The resultant hip force causes a varus torque which must be compensated by a shear force couple depending on the stem alignment of the prosthesis. Since the prosthesis is substantially less flexible than the bone, the interior of the femur
Publikováno v:
Der Orthopäde. 47:52-66
Mit der steigenden Anzahl von Endoprothesentragern wird die Revision von Huftendoprothesen weiter zunehmen. Die Rekonstruktion ossarer Defekte mit allogenen Knochen ermoglicht die Wiederherstellung eines knochernen Lagers und verbessert die langfrist
Autor:
Bernd Ishaque, Carlos Alfonso Fonseca Ulloa, Alexander Jahnke, Markus Rickert, J.B. Seeger, Suleiman Ghandourah, Gafar Adam Ahmed
Publikováno v:
Journal of biomechanical engineering. 142(12)
Cementless straight stems show very good survival rates. However, the more distal force application of straight stems may lead to release-related proximal stress-shielding. Nevertheless, this technical brief had the objective of conducting a biomecha