Zobrazeno 1 - 10
of 24
pro vyhledávání: '"Gabriel Benmouyal"'
Publikováno v:
Electric Power Transformer Engineering ISBN: 9781315217215
Electrical Engineering Handbook ISBN: 9780849391866
Electrical Engineering Handbook ISBN: 9780849391866
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::3204b13b5b3daa1605e9bb3d8244f74d
https://doi.org/10.1201/b12110-19
https://doi.org/10.1201/b12110-19
Publikováno v:
Electric Power Transformer Engineering ISBN: 9781315217215
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::2415e40c3f0b8816b1927b25fdaa7f00
https://doi.org/10.1201/b12110-20
https://doi.org/10.1201/b12110-20
Publikováno v:
2017 70th Annual Conference for Protective Relay Engineers (CPRE).
Mho elements constitute the main component of transmission line protection in North America and many countries overseas. Distance elements based on incremental quantities and derived from the same base equations as mho elements emerged about two deca
Autor:
Miroslav M. Begovic, D. Hamai, Bogdan Z. Kasztenny, Kenneth E. Martin, B. Dickerson, Christopher Huntley, J.Y. Cai, G. Brunello, J. Salj, J. Sperr, E. Price, Gabriel Benmouyal, Arun G. Phadke, V. Gharpure, Mark Adamiak, J. Burger, B. Kennedy, Veselin Skendzic, D. Karlsson, S. Anderson, Y. Song
Publikováno v:
IEEE Transactions on Power Delivery. 23:1805-1811
IEEE Standard 1344-1995 [1] on measurement of synchronized phasors of power system currents and voltages has been revised and published as IEEE Standard C37.118-2005 [2]. This paper has been prepared by the IEEE Working Group who developed the revise
Autor:
Stanley E. Zocholl, Gabriel Benmouyal
Publikováno v:
IEEE Transactions on Power Delivery. 20:1240-1246
Standards specify an equation for the time-current characteristic of a thermal relay. When the equation is published without reference to its derivation, it may be mistaken for the characteristic of an inverse-time overcurrent relay which if implemen
Publikováno v:
IEEE Transactions on Power Delivery. 17:886-893
For pt.I see ibid., vol.16, p.485-91 (2001). This paper describes a new approach for transformer differential protection that ensures security for external faults, inrush, and overexcitation conditions and provides dependability for internal faults.
Autor:
Veselin Skendzic, L. Kojovic, M. Meisinger, Mladen Kezunovic, S. Chano, P.G. McLaren, R. Marttila, G.L. Michel, M.S. Sachdev, A. Girgis, K.K. Mustaphi, Tarlochan S. Sidhu, D.A. Tziouvaras, C.F. Henville, Gabriel Benmouyal
Publikováno v:
IEEE Transactions on Power Delivery. 16:238-245
This paper reviews the past and present uses of relay models. It discusses the various types of models, what information is required to build such models and the model validation process. Examples of present and possible future use of software models
Publikováno v:
2013 66th Annual Conference for Protective Relay Engineers.
This paper discusses the factors to consider for sizing current transformers (CTs) for line protection applications. We first cover CT basics, with emphasis on errors and ac and dc saturation. We also discuss the criteria to avoid CT saturation. Then
Autor:
John Byrne-Finley, Daqing Hou, Gabriel Benmouyal, D.A. Tziouvaras, Brian Smyth, Normann Fischer
Publikováno v:
2012 65th Annual Conference for Protective Relay Engineers.
One of the traditional techniques for detecting power swings uses a dual-quadrilateral characteristic. It is based on the measurement of the time interval it takes the positive-sequence impedance to cross two blinders. Another technique monitors the
Publikováno v:
2012 65th Annual Conference for Protective Relay Engineers.
Fault location information is critical for operating and maintaining transmission networks. Some of the challenges in calculating accurate fault location include fault resistance, zero-sequence mutual coupling, load, system nonhomogeneity, and transm