Publikováno v:
Analytical Chemistry. 54:1458-1466
Autor:
A.N. Buijserd, G.J. Louter
Publikováno v:
International Journal of Mass Spectrometry and Ion Physics. 50:245-257
A fully operational, electro-optical system for simultaneous detection is discussed. This system is applied to the simultaneous detection of mass spectra, obtained by collision-activated dissociation experiments. The detector itself consists of a che
Publikováno v:
International Journal of Mass Spectrometry and Ion Physics. 33:335-347
A tandem mass spectrometer is described for studies of collision-induced dissociation. This instrument is especially suited for investigations on organic molecules, e.g. biochemical substances, for m/z values up to 1000. The first stage is formed by
Publikováno v:
Zeitschrift für Naturforschung C. 35:6-11
Collision Induced Dissociation (C ID),C ollisional Activation (CA), Pyrolysis, Mycobacterium, Mass Spectrometry An apparatus is described for Collision Induced Dissociation Mass Spectrometry, where es sential increase in sensitivity in the detectio
Publikováno v:
International Journal of Mass Spectrometry and Ion Physics. 40:341-349
Two calibration methods for fragment mass spectra, derived by means of collisionally-activated dissociation (CAD) in a tandem mass spectrometer, are discussed here. The instrument has variable dispersion and is equipped with an electro-optical, simul
Publikováno v:
International Journal of Mass Spectrometry and Ion Physics. 39:197-218
A matrix representation of the ion optics of the analyzing stage has been used in a computer model of a tandem mass spectrometer with simultaneous detection for CAD. The matrix algorithm of this model is discussed here as an elegant way of describing
Publikováno v:
International Journal of Mass Spectrometry and Ion Physics. 46:131-134
Publikováno v:
Nuclear Instruments and Methods in Physics Research. 187:137-142
First order matrix calculations on the ion optics of the second stage of a tandem mass spectrometer with variable dispersion (1250-37.5 mm) and simultaneous detection (mass range 1 : 1.06 to 1 : 12) are given. This second stage consists of a post-acc
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.