Publikováno v:
Pacing and Clinical Electrophysiology. 20:226-229
We postulated that reducing peak leading edge shock voltage and its rate of rise (waveform rounding) would reduce energy requirements for cardioversion of AF and AFl, and may therefore reduce patient discomfort. Transvenous defibrillating catheters (
Publikováno v:
Pacing and Clinical Electrophysiology. 18:28-33
Using a unipolar esothoracic pacing system (where current passes from a point source positioned in the distal esophagus to a chest wall pad) and pulse duration of 50 msec, satisfactory 1:1 ventricular capture was obtained in 57 (86%) of 66 patients,
Autor:
S.R. McMechan, A.A.J. Adgey, Gilbert MacKenzie, G. Wright, G.J. Dempsey, J Anderson, M. Crawley, C. Cullen
Publikováno v:
Journal of Electrocardiology. 27:117-120
Using a newly developed 64-electrode portable mapping device, QRS and ST-T isointegral maps were compared in 194 control subjects and 101 patients. One hundred ninety-four control subjects (mean age, 48 years; 120 men) with no history of cardiac dise
Publikováno v:
Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
The conventional clinical procedure in an electrophysiological study (EPS) involves transvenous catheterisation and access to X-ray fluoroscopy. Esothoracic electrophysiology (ETE) is a viable non-invasive alternative for conducting EPS without acces
Publikováno v:
Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
Discusses the use of the impedance cardiogram (ICG) obtained from a two electrode system in comparison with the standard 4 electrode configuration. Improved sensitivity and specificity when the ICG is synchronised with the R wave component of the ECG
Publikováno v:
Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
The interpolation of information missing from specific electrode sites in Electrocardiographic Body Surface Maps (BSMs) is evaluated using several common methods. Although some of these methods frequently provide an accurate reproduction of the origi
Publikováno v:
European heart journal. 19(12)
AIMS The American Heart Association has endorsed the concept of Public Access Defibrillation. However, there have been reports of inappropriate direct current shocks from automatic external defibrillators. The specificity of automatic external defibr
Autor:
J Anderson, M. Crawley, Gilbert MacKenzie, John Allen, S.R. McMechan, G.J. Dempsey, A.A.J. Adgey, G. Wright
Publikováno v:
Journal of electrocardiology.
An algorithm for the early detection of acute myocardial infarction (MI) using body surface electrocardiographic potential mapping has been developed. The mapping system consists of a 64-hydrogel electrode harness applied rapidly to the anterior ches
Publikováno v:
Proceedings of First International Caracas Conference on Devices, Circuits and Systems.
Conventional electrophysiological study of the heart requires very low energy stimulation pulses but, transvenous catherisation and access to x-ray fluoroscopy, are necessary for this clinical procedure. An interface module was developed in order to
Publikováno v:
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
A screen printed flexible harness has been developed in order to capture 64 body surface electrocardiograms. The harness technology is new and has benefited cases where ‘one touch applications’ are required as in the study of body surface mapping