Zobrazeno 1 - 10
of 30
pro vyhledávání: '"G. Roziere"'
Publikováno v:
J X Ray Sc Technol
J X Ray Sc Technol, 1996, 6, pp.205--221
J X Ray Sc Technol, 1996, 6, pp.205--221
Actual assessment of the modulation transfer function (MTF) of a physical system requires objective experimental data to be obtained. This paper presents four practical methods for measuring the MTF of a linear x-ray detector. These methods are based
Publikováno v:
SPIE Proceedings.
The presentation concerns evaluations that were made to demonstrate the feasibility of a solid state detector intended to produce digital images in slit scan mammography equipment. The detector designed for this modality consists of a multilinear arr
Publikováno v:
SPIE Proceedings.
Solid state x-ray detectors produce high resolution medical images when scanning the patient with a narrow x-ray beam. The x-ray detection is achieved by a silicon photodiode array coated by a scintillating material. Signal is multiplexed and convert
Publikováno v:
IEEE Transactions on Nuclear Science. 28:60-63
Two years ago, a gamma camera detector, consisting of a 34 cm input field image intensifier coupled to a scintillator crystal at the input and to a silicon localizer at the output, was built and tested at Thomson-CSF. Snce that time the 34-cm model h
Autor:
R. de Ceccatty, G. Roziere
Publikováno v:
Bulletin de la Société Géologique de France. :437-440
The artificial-looking regular conical perforations in many of the slaty pebbles found on the Marquesado del Cenete plain in Granada, Spain, are attributed to the particular nature (foliated) of the rock and local climatic conditions.
Publisher Summary A position-sensing detector employing continuous resistive electrodes as charge dividers have been extensively described in the past. A few years ago, two-dimensional position localizers were incorporated in electronic tubes for the
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::61e4f95a1dffbdbd56bde61a49b3d647
https://doi.org/10.1016/s0065-2539(08)61610-8
https://doi.org/10.1016/s0065-2539(08)61610-8
Publikováno v:
SPIE Proceedings.
Linear solid state X-ray detectors are used to produce digital images. The detectors produce the X-ray image line by line as the patient is scanned with a narrow X-ray beam. One of the decisive advantages of this principle of imaging is that it rejec
Publisher Summary This chapter examines the improvements to an image intensifier for a γ-ray scintillation camera. A 35 cm input field image intensifier tube designed for scintillation cameras was described at the Fifth Symposium on Photo-Electronic
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::75c325324891ef0c8a2a6fc0d75e5e7d
https://doi.org/10.1016/s0065-2539(08)61459-6
https://doi.org/10.1016/s0065-2539(08)61459-6
Publikováno v:
International Topical Meeting on Image Detection and Quality.
We describe an X-ray solid state detector of 1024 pixels. We give the principle of operation, the performance, and mention the main advantages of using this detector in the industrial non destructive testing systems and medical radiologic systems.
Publisher Summary This chapter discusses the image device for gamma cameras incorporating a solid-state localizer. It describes a new image intensifier gamma camera tube that completely eliminates the need for photomultipliers, by incorporating a sil
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::5eaecc27161a20ddc4c36ee6d3f99e8f
https://doi.org/10.1016/s0065-2539(08)60722-2
https://doi.org/10.1016/s0065-2539(08)60722-2