Publikováno v:
American Journal of Roentgenology. 169:1371-1379
Autor:
G. H. Bardy, P. L. Sawyer
Publikováno v:
Clinical Cardiology. 13:425-433
The development of catheter ablation techniques for therapy of cardiac arrhythmias continues to evolve. Although many patients have benefited from catheter ablation procedures, failure to ablate the arrhythmogenic substrate and complications from the
Publikováno v:
Biomag 96 ISBN: 9781461270669
We have compared simulated magnetocardiograms (MCGs), calculated using a high resolution heart-torso model of an adult subject, with measured MCGs acquired from the same individual. Most of the Channels showed good qualitative agreement between measu
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::57f238ce3c49e14ab07fef3cade28fce
https://doi.org/10.1007/978-1-4612-1260-7_111
https://doi.org/10.1007/978-1-4612-1260-7_111
Autor:
B E, Gliner, D B, Jorgenson, J E, Poole, R D, White, K G, Kanz, T D, Lyster, K W, Leyde, D J, Powers, C B, Morgan, R A, Kronmal, G H, Bardy
Publikováno v:
Biomedical instrumentationtechnology. 32(6)
Few victims of sudden cardiac arrest survive. A new generation of automatic external defibrillators (AEDs), smaller, lighter, easier to use, and less costly, makes the goal of widespread AED deployment and early defibrillation feasible. A low-energy
Autor:
J E, Poole, R D, White, K G, Kanz, F, Hengstenberg, G T, Jarrard, J C, Robinson, V, Santana, D K, McKenas, N, Rich, S, Rosas, S, Merritt, L, Magnotto, J V, Gallagher, B E, Gliner, D B, Jorgenson, C B, Morgan, S M, Dillon, R A, Kronmal, G H, Bardy
Publikováno v:
Journal of cardiovascular electrophysiology. 8(12)
New automatic external defibrillators (AEDs), which are smaller, lighter, easier to use, and less costly make the goal of widespread AED deployment and early defibrillation for out-of-hospital cardiac arrest feasible. The objective of this study was
Publikováno v:
Pacing and clinical electrophysiology : PACE. 20(1 Pt 2)
Replacing one defibrillation electrode lead by the defibrillator can may simplify implantation of the ICD. In this multicenter study, 304 patients were randomized to receive either the biphasic active can (AC) (model 7219C system, Medtronic, Inc.) or
Autor:
G H, Bardy, F E, Marchlinski, A D, Sharma, S J, Worley, R M, Luceri, R, Yee, B D, Halperin, C L, Fellows, T S, Ahern, D A, Chilson, D L, Packer, D J, Wilber, T A, Mattioni, R, Reddy, R A, Kronmal, R, Lazzara
Publikováno v:
Circulation. 94(10)
The most important factor for improving out-of-hospital ventricular fibrillation survival rates is early defibrillation. This can be achieved if small, lightweight, inexpensive automatic external defibrillators are widely disseminated. Because automa
Autor:
G. H. Bardy, R. K. Reddy
Publikováno v:
HerzschrittmachertherapieElektrophysiologie. 8(1)
With simple, single lead unipolar pectoral defibrillators, ICD technology has reached a level of ease and safety comparable to pacemaker implantation. It will be difficult to further decrease the morbidity associated with ICD implantation; just as it
Publikováno v:
Journal of the American College of Cardiology. 28(2)
The purpose of this study was to prospectively examine in a multicenter study the methods of use, efficacy and complications of a unipolar cardioverter-defibrillator in patients at risk for sudden cardiac death.Implantation of cardioverter-defibrilla
Autor:
M. Traversa, Maria Vittoria Pitzalis, G. H. Bardy, C. D. Dicandia, Stefano Favale, Paolo Rizzon
Publikováno v:
European heart journal. 16(5)
In this report a transvenous cardioverter defibrillator implantation is described in two patients with a persistent left-sided superior vena cava and right SVC atresia. In the first case, manoeuvring of the guide wire inserted through the left subcla