Publikováno v:
IEEE Transactions on Applied Superconductivity. 16:293-296
The present Alternating Gradient Synchrotron (AGS) injection kicker magnets at the A5 location were designed for 1.5 GeV proton injection. Recent high intensity runs have pushed the transfer kinetic energy to 1.94 GeV, but with an imperfect matching
Autor:
P. T. Debevec, R. McNabb, C. S. Özben, T. I. Banks, K. L. Giovanetti, C. C. Polly, P. A. Zolnierczuk, V. Tishchenko, M. Hance, Kenneth M. Crowe, C. J. G. Onderwater, M. F. Hare, S. M. Clayton, D. M. Webber, Susanne Rath, B. Lauss, Françoise Mulhauser, J. Wasserman, T. P. Gorringe, D. B. Chitwood, S. Dhamija, J. P. Miller, K. R. Lynch, B. L. Roberts, null null, C. S. Oezben, D. W. Hertzog, S. Cheekatmalla, R. M. Carey, B. Kiburg, S. Battu, Q. Peng, M. J. Barnes, I. Logashenko, P. Winter, J. Crnkovic, J. Kunkle, A. Gafarov, W. Earle, P. Kammel, F. Gray, G. D. Wait
Publikováno v:
Physical Review Letters, 99(3). American Physical Society
Physical Review Letters, 99(3):032001. AMER PHYSICAL SOC
Physical Review Letters, 99(3):032001. AMER PHYSICAL SOC
The mean life of the positive muon has been measured to a precision of 11 ppm using a low-energy, pulsed muon beam stopped in a ferromagnetic target, which was surrounded by a scintillator detector array. The result, tau_mu = 2.197013(24) us, is in e
Autor:
O. H. Gish, G. R. Wait
Publikováno v:
Journal of Geophysical Research. 55:473-484
In a joint project of the Department of Terrestrial Magnetism, Carnegie Institution of Washington, and the United States Air Force, acceptable electric surveys were made over the tops of 21 thunderstorms in the central United States during July to Oc
Publikováno v:
Physical Review. 32:967-973
The magnetic permeability of iron wire at high frequencies.---G. R. Wait, investigating the magnetic permeability of iron and magnetite in high frequency magnetic fields, did not observe a critical variation of the permeability at about 3000 kilocycl
Autor:
H. W. Rawlings, G. H. Wait
Publikováno v:
Oil & Soap. 23:83-87
By means of simple statistical methods the effects of technique, laboratory equipment, solvents, temperature, and instruments on the precision and accuracy of the determination of the extinction coefficient at 328 mµ of fish liver oils are outlined.
Autor:
G. D. Wait
Publikováno v:
Nuclear Applications. 4:440-447
Autor:
G. R. Wait
Publikováno v:
Zeitschrift f�r Physik. 77:695-698
Die Herren Malov und Arkadiew haben kurzlich die Ansicht vertreten, das die Resultate, die ich im Jahre 1927 nach der heterodynen Schwebungsmethode erhalten habe, eine systematische Abnahme der Permeabilitat mit abnehmender Frequenz zeigten. Das ist
Autor:
G. R. Wait
Publikováno v:
Physical Review. 29:566-578
Relative values of the permeability of cast-iron filings, iron wires, and iron powder in high frequency magnetic fields.---Wwedensky and Theodortschik have found the magnetic permeability of iron, steel, and nickel in alternating fields to be abnorma
Autor:
G. R. Wait
Publikováno v:
Archiv für Meteorologie, Geophysik und Bioklimatologie Serie A. 3:70-76
The electric current passing vertically through thunderstorms has been measured above the thunderheads with apparatus mounted on a B-29 airplane. The direction of the resulting current, in all cases, was such as to maintain the negative charge found