Zobrazeno 1 - 10
of 38
pro vyhledávání: '"G. A. Prophet"'
Autor:
Benjamin Sun, Alan J. Snyder, Gerson Rosenberg, Robert G Strange, William J. Weiss, Eric M Hoenicke, William S. Pierce, M. Rawhouser, Walter E. Pae, G. Allen Prophet
Publikováno v:
The Annals of Thoracic Surgery. 71:S150-S155
Background . Two modifications of the surgical implantation protocol for the Penn State Total Artificial Heart (ETAH) were evaluated: Phrenic nerve ischemia was prevented by minimizing dissection and traction; and hemostasis was augmented and ETAH cu
Autor:
Alan J. Snyder, Gerson Rosenberg, G. A. Prophet, M. Rawhouser, E. Stephenson, William S. Pierce, H. Kuroda, William J. Weiss, W. J. Pae
Publikováno v:
ASAIO Journal. 44:M613-M618
In long-term studies testing the Penn State Total Artificial Heart involving 30 calves, seven calves died of pulmonary complications within 2 weeks after receiving the implant (Group 1 [G1]) and seven calves survived from 2 weeks to 3 months without
Autor:
S. Ford, M. Rawhouser, William S. Pierce, H. Kusagawa, Dennis Hicks, R.A. Nazarian, Alan J. Snyder, G. A. Prophet, G Rosenberg, John A. Marlotte, Sanjay M. Mehta, William J. Weiss
Publikováno v:
ASAIO JOURNAL. 42:M342-346
The total artificial heart under development by the Pennsylvania State University and 3M Health Care has undergone a number of design improvements to improve reliability, manufacturability, implantability, and performance. These improvements are near
Autor:
ALAN J. SNYDER, GERSON ROSENBERG, WILLIAM J. WEISS, SPENCER K. FORD, RICHARD A. NAZARIAN, DENNIS L. HICKS, JOHN A. MARLOTTE, OSAMU KAWAGUCHI, G. ALLEN PROPHET, JOHN S. SAPIRSTEIN, MARK SCHWARTZ, WILLIAM S. PIERCE
Publikováno v:
ASAIO Journal. 39:M177-M184
The authors performed 14 implants of a completely implanted total artificial heart (TAH) system in calves. The system consisted of a dual pusher plate rollerscrew energy converter, two sac type blood pumps, an implanted electronic control and battery
Autor:
Sankholkar Sachin A, Christopher T. Ducko, Edward R. Stephenson, Ralph J. Damiano, Eric M Hoenicke, G. Allen Prophet
Publikováno v:
The Annals of thoracic surgery. 68(3)
Background . With traditional instruments, endoscopic coronary artery bypass grafting (ECABG) has not been possible. This study was designed to determine the feasibility of using a robotically-assisted microsurgical system to perform ECABG in a chron
Autor:
Alan J. Snyder, M. Rawhouser, G. A. Prophet, T.J. Cleary, Gerson Rosenberg, John D. Reibson, Sanjay M. Mehta, William J. Weiss, Hitoshi Kusagawa
Publikováno v:
Artificial organs. 22(1)
In vivo characterization studies were performed to compare the dynamic in vivo performance of the Penn State/3M Health Care electric total artificial heart to existing in vitro data. Fully implanted systems were utilized including the artificial hear
Autor:
A J, Snyder, G, Rosenberg, W J, Weiss, S K, Ford, R A, Nazarian, D L, Hicks, J A, Marlotte, O, Kawaguchi, G A, Prophet, J S, Sapirstein
Publikováno v:
ASAIO journal (American Society for Artificial Internal Organs : 1992). 39(3)
The authors performed 14 implants of a completely implanted total artificial heart (TAH) system in calves. The system consisted of a dual pusher plate rollerscrew energy converter, two sac type blood pumps, an implanted electronic control and battery
Autor:
Alan J. Snyder, John D. Reibson, Juan D. Arenas, O. Kawaguchi, Gerson Rosenberg, S. McGary, B. Daily, J. H. Donachy, G. A. Prophet, William S. Pierce, Reed D. Quinn
Publikováno v:
ASAIO journal (American Society for Artificial Internal Organs : 1992). 38(3)
An electric motor driven orthotopic artificial heart was implanted in a 110 kg female Holstein calf as part of a series of 12 such implants intended to demonstrate the in vivo durability and compatibility of the device. The device uses pusher plates
Autor:
D L, Amrani, C, Christensen, L, Hauerwas, M, Rieder, M W, Mosesson, D, Schmidt, R, Flemma, G A, Prophet, W, Pierce
Publikováno v:
ASAIO transactions. 37(3)
The authors evaluated the potential for thrombotic complications arising from implantation of a ventricular assist device (Sarns/3M-VAD) in four calves. Coagulation screening tests (prothrombin time [PT], partial thromboplastin time [PTT], thrombin t
Autor:
E S, Bour, C B, Wisman, J D, Arenas, G A, Prophet, C A, Miller, J H, Donachy, J A, Waldhausen
Publikováno v:
ASAIO transactions. 36(3)
A right ventricular assist device (VAD) based on the principle of counterpulsation has been developed at our institution. The device is a valveless, pneumatically actuated, 40 cc, sac-type pump, with a single inlet-outlet port. For right ventricular