Zobrazeno 1 - 10
of 17
pro vyhledávání: '"G M, Dappen"'
Publikováno v:
Clinical Chemistry. 28:2366-2372
In this slide, unconjugated bilirubin and its sugar conjugates interact with a cationic polymeric mordant to form spectrally enhanced complexes having similar absorptivities at approximately 400 nm. With reflection densitometry and appropriate mathem
Autor:
T W Esders, C T Goodhue, B Bruschi, R N Rand, J Figueras, R W Spayd, R W Nelson, Tai-Wing Wu, D D LaRossa, J N Eikenberry, G M Dappen, B A Burdick
Publikováno v:
Clinical Chemistry. 24:1343-1350
Using the general concept of a dry multilayer analytical element, we can change chemical procedures and configurations to assay several blood components. In the assay of serum urea nitrogen, urease in the reagent layer catalyzes the hydrolysis of ure
Publikováno v:
Clinical Chemistry. 30:1310-1313
We compared results for total bilirubin as measured on a coated thin film and by the Evelyn-Malloy and Jendrassik-Gróf methods. We examined serum samples from patients and studied the effects of protein, hemoglobin, and lipids on bilirubin measureme
Autor:
G M Dappen, Tai-Wing Wu, G M Underwood, S Y Lynn, R E Snoke, C T Goodhue, P E Cumbo, D M Sablauskas, B F Nellis, C D Warburton, J R Schaeffer, R M Schubert, C C Morganson
Publikováno v:
Clinical Chemistry. 28:1159-1162
We have prepared a dry film for the enzymic determination of total serum cholesterol. It consists of a transparent support bearing a buffered gelatin layer, and a white reflective spreading layer that contains all of the necessary components for the
Publikováno v:
Clinical Chemistry. 30:1314-1317
We used two coated thin films to measure the concentrations of unconjugated, conjugated, and total bilirubin as well as bilirubin covalently bound to albumin ("delta" bilirubin) in more than 400 serum samples. We measured the unconjugated and conjuga
Publikováno v:
Clinical Chemistry. 30:1304-1309
Using dual-wavelength spectrometry, we have refined the mordant-based bilirubin slide method (Clin Chem 28:2366-2372, 1982) to co-detect unconjugated bilirubin (Bu) and its sugar conjugates (Bc) in 10 microL of serum. The assay is based on three prin
Autor:
G M Dappen, D E Hill, Tai-Wing Wu, C P Glover, R N Rand, T W Eder, H G Curme, R L Columbus, C A Goffe, J Figueras, Karl John Sanford, W H Lawton, J E Pinney, E J Muka, W D Fellows
Publikováno v:
Clinical Chemistry. 24:1335-1342
Dry, thin films containing all necessary reagents for clinical analysis by colorimetry have been designed. Reagents in a matrix of hydrophilic polymer are coated on top of a transparent plastic base. A white isotropically porous polymer spreading lay
Publikováno v:
Clinical Chemistry. 29:37-41
We have prepared a diazo-based dry film for use in determining total serum bilirubin. On a transparent support are a buffered gelatin layer containing a polymeric quaternary amine (the mordant) and a white, reflective spreading layer that contains al
Publikováno v:
The Journal of Organic Chemistry. 29:2813-2815
Autor:
R W, Spayd, B, Bruschi, B A, Burdick, G M, Dappen, J N, Eikenberry, T W, Esders, J, Figueras, C T, Goodhue, D D, LaRossa, R W, Nelson, R N, Rand, T W, Wu
Publikováno v:
Clinical chemistry. 24(8)
Using the general concept of a dry multilayer analytical element, we can change chemical procedures and configurations to assay several blood components. In the assay of serum urea nitrogen, urease in the reagent layer catalyzes the hydrolysis of ure