Publikováno v:
[1990] Proceedings Computers in Cardiology.
Software was developed to pilot an injection pump, easily adaptable to each type of drug and equipment. A computerized infusion system was utilized during pacemaker implantation. The study was performed in five patients. Hypnomidate was infused via a
Publikováno v:
[1990] Proceedings Computers in Cardiology.
Before programming a dual-chamber pacemaker (PM), the physician must take into account the patient's (pt) clinical profile. Such software is now included in the PM programmer software, supported by a PC computer. It allows direct programming of the P
Publikováno v:
Pacing and clinical electrophysiology : PACE. 21(1 Pt 1)
A rate responsive minute ventilation (VE) pacemaker was implanted in 49 patients (70.8 +/- 40.0 years). A Chorus RM 7034 pacemaker was implanted in 43 patients and an Opus RM 4534 in six patients. Four sensor configurations were compared: atrial conf
Publikováno v:
Pacing and clinical electrophysiology : PACE. 19(11 Pt 2)
Formal Monitoring of Performance is Still Needed. In order to detect trends in the number of device or component failures that have occurred among permanent pacemaker systems since the 1970s, we reviewed the data of the five largest pacemaker manufac
Publikováno v:
EP Europace. 7:198-198
Publikováno v:
Pacing and Clinical Electrophysiology. 19:1006-1007
Autor:
L. Guize, J. Y. Le Heuzey, C. Allonso, Jean-Marc Darondel, J. Ollitrault, T. Lavergne, M. Ait Said, G. Pioger, C. Juin
Publikováno v:
EP Europace. 4:B123-B123
Results: Baseline (unpaced) interVA and LVdPdhmx did not differ signficandy before and after the S-week BiV pacing period (-30&71x and -30&8ms and 1867~456mmHgis and 1964&316mmHg/s, respectively). Maximal increase in LVdPdhmx was similar during acute
Publikováno v:
Pacing and Clinical Electrophysiology. 14:602-602
Publikováno v:
IFAC Proceedings Volumes. 12:226-232
A digital computer program of simulation has been written in order to study' the dynamic behaviour of the network over long periods of time (several tens of minutes). The simulation is achieved in disturbed and in normal operations (when the network
Publikováno v:
Pacing and Clinical Electrophysiology. 6:372-375
Le systems de detection de ľactivite auriculaire present dans les stimulaleurs actuels VDD ou DDD ne permet pas de faire avec certitude to distinction entre ľactivit? aurieulaire normale et retrograde. Il apparait done necessaire de mettre au point