Zobrazeno 1 - 10
of 489
pro vyhledávání: '"Frossati, G."'
Autor:
Alessandria, F., Ardito, R., Artusa, D. R., Avignone III, F. T., Azzolini, O., Balata, M., Banks, T. I., Bari, G., Beeman, J., Bellini, F., Bersani, A., Biassoni, M., Bloxham, T., Brofferio, C., Bucci, C., Cai, X. Z., Canonica, L., Capelli, S., Carbone, L., Cardani, L., Carrettoni, M., Casali, N., Chott, N., Clemenza, M., Cosmelli, C., Cremonesi, O., Creswick, R. J., Dafinei, I., Dally, A., Datskov, V., De Biasi, A., Decowski, M. P., Deninno, M. M., Di Domizio, S., di Vacri, M. L., Ejzak, L., Faccini, R., Fang, D. Q., Farach, H. A., Ferri, E., Ferroni, F., Fiorini, E., Franceschi, M. A., Freedman, S. J., Frossati, G., Fujikawa, B. K., Giachero, A., Gironi, L., Giuliani, A., Goett, J. J., Gorla, P., Gotti, C., Guardincerri, E., Gutierrez, T. D., Haller, E. E., Han, K., Heeger, K. M., Huang, H. Z., Kadel, R., Kazkaz, K., Keppel, G., Kogler, L., Kolomensky, Yu. G., Lenz, D., Li, Y. L., Ligi, C., Liu, X., Ma, Y. G., Maiano, C., Maino, M., Martinez, M., Maruyama, R. H., Moggi, N., Morganti, S., Napolitano, T., Newman, S., Nisi, S., Nones, C., Norman, E. B., Nucciotti, A., Orio, F., Orlandi, D., Ouellet, J. L., Pallavicini, M., Palmieri, V., Pattavina, L., Pavan, M., Pedretti, M., Pessina, G., Pirro, S., Previtali, E., Rampazzo, V., Rimondi, F., Rosenfeld, C., Rusconi, C., Sangiorgio, S., Scielzo, N. D., Sisti, M., Smith, A. R., Stivanello, F., Taffarello, L., Tenconi, M., Tian, W. D., Tomei, C., Trentalange, S., Ventura, G., Vignati, M., Wang, B. S., Wang, H. W., Whitten Jr., C. A., Wise, y T., Woodcraft, A., Zanotti, L., Zarra, C., Zhu, B. X., Zucchelli, S.
Publikováno v:
JCAP 01 (2013) 038
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three of them we were able to set the energy threshold around 3 keV using a new analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3 keV to 2 cpd/keV/kg
Externí odkaz:
http://arxiv.org/abs/1209.2519
Autor:
Alessandria, F., Andreotti, E., Ardito, R., Arnaboldi, C., Avignone III, F. T., Balata, M., Bandac, I., Banks, T. I., Bari, G., Beeman, J. W., Bellini, F., Bersani, A., Biassoni, M., Bloxham, T., Brofferio, C., Bryant, A., Bucci, C., Cai, X. Z., Canonica, L., Capelli, S., Carbone, L., Cardani, L., Carrettoni, M., Chott, N., Clemenza, M., Cosmelli, C., Cremonesi, O., Creswick, R. J., Dafinei, I., Dally, A., De Biasi, A., Decowski, M. P., Deninno, M. M., de Waard, A., Di Domizio, S., Ejzak, L., Faccini, R., Fang, D. Q., Farach, H., Ferri, E., Ferroni, F., Fiorini, E., Foggetta, L., Freedman, S., Frossati, G., Giachero, A., Gironi, L., Giuliani, A., Gorla, P., Gotti, C., Guardincerri, E., Gutierrez, T. D., Haller, E. E., Han, K., Heeger, K. M., Huang, H. Z., Ichimura, K., Kadel, R., Kazkaz, K., Keppel, G., Kogler, L., Kolomensky, Y. G., Kraft, S., Lenz, D., Li, Y. L., Liu, X., Longo, E., Ma, Y. G., Maiano, C., Maier, G., Martinez, C., Martinez, M., Maruyama, R. H., Moggi, N., Morganti, S., Newman, S., Nisi, S., Nones, C., Norman, E. B., Nucciotti, A., Orio, F., Orlandi, D., Ouellet, J., Pallavicini, M., Palmieri, V., Pattavina, L., Pavan, M., Pedretti, M., Pessina, G., Pirro, S., Previtali, E., Rampazzo, V., Rimondi, F., Rosenfeld, C., Rusconi, C., Salvioni, C., Sangiorgio, S., Schaeffer, D., Scielzo, N. D., Sisti, M., Smith, A. R., Stivanello, F., Taffarello, L., Terenziani, G., Tian, W. D., Tomei, C., Trentalange, S., Ventura, G., Vignati, M., Wang, B., Wang, H. W., Whitten Jr, C. A., Wise, T., Woodcraft, A., Xu, N., Zanotti, L., Zarra, C., Zhu, B. X., Zucchelli, S.
The CUORE Crystal Validation Runs (CCVRs) have been carried out since the end of 2008 at the Gran Sasso National Laboratories, in order to test the performances and the radiopurity of the TeO$_2$ crystals produced at SICCAS (Shanghai Institute of Cer
Externí odkaz:
http://arxiv.org/abs/1108.4757
Autor:
Arnaboldi, C., Artusa, D. R., Avignone III, F. T., Balata, M., Bandac, I., Barucci, M., Beeman, J. W., Bellini, F., Brofferio, C., Bucci, C., Capelli, S., Carbone, L., Cebrian, S., Clemenza, M., Cremonesi, O., Creswick, R. J., de Waard, A., Di Domizio, S., Dolinski, M. J., Farach, H. A., Fiorini, E., Frossati, G., Giachero, A., Giuliani, A., Gorla, P., Guardincerri, E., Gutierrez, T. D., Haller, E. E., Maruyama, R. H., McDonald, R. J., Nisi, S., Nones, C., Norman, E. B., Nucciotti, A., Olivieri, E., Pallavicini, M., Palmieri, E., Pasca, E., Pavan, M., Pedretti, M., Pessina, G., Pirro, S., Previtali, E., Risegari, L., Rosenfeld, C., Sangiorgio, S., Sisti, M., Smith, A. R., Torres, L., Ventura, G., Vignati, M.
Publikováno v:
Phys.Rev.C78:035502,2008
A detailed description of the CUORICINO $^{130}Te$ neutrinoless double-beta ($\nbb$) decay experiment is given and recent results are reported. CUORICINO is an array of 62 tellurium oxide ($TeO_{2}$) bolometers with an active mass of 40.7 kg. It is c
Externí odkaz:
http://arxiv.org/abs/0802.3439
Autor:
Gottardi, L., de Waard, A., Usenko, A., Frossati, G., Podt, M., Flokstra, J., Bassan, M., Fafone, V., Minenkov, Y., Rocchi, A.
Publikováno v:
Phys.Rev.D76:102005,2007
We present the performances and the strain sensitivity of the first spherical gravitational wave detector equipped with a capacitive transducer and read out by a low noise two-stage SQUID amplifier and operated at a temperature of 5 K. We characteriz
Externí odkaz:
http://arxiv.org/abs/0705.0122
Autor:
Castellano, M. G., Chiarello, F., Leoni, R., Mattioli, F., Torrioli, G., Carelli, P., Cirillo, M., Cosmelli, C., de Waard, A., Frossati, G., Grønbech-Jensen, N., Poletto, S.
Publikováno v:
Physical Review Letters Vol.98, 177002 (2007)
We report on a direct quantitative comparison between Thom's general catastrophe theory for systems presenting discontinuous behavior and experimental reality. It is demonstrated that the model provides a striking quantitative description of the meas
Externí odkaz:
http://arxiv.org/abs/cond-mat/0609038
Autor:
Arnaboldi, C., Artusa, D. R., Avignone III, F. T., Balata, M., Bandac, I., Barucci, M., Beeman, J. W., Brofferio, C., Bucci, C., Capelli, S., Carbone, L., Cebrian, S., Cremonesi, O., Creswick, R. J., de Waard, A., Farach, H. A., Fiorini, E., Frossati, G., Guardincerri, E., Giuliani, A., Gorla, P., Haller, E. E., McDonald, J., Norman, E. B., Nucciotti, A., Olivieri, E., Pallavicini, M., Palmieri, E., Pasca, E., Pavan, M., Pedretti, M., Pessina, G., Pirro, S., Previtali, E., Risegari, L., Rosenfeld, C., Sangiorgio, S., Sisti, M., Smith, A. R., Torres, L., Ventura, G.
Publikováno v:
Phys.Rev.Lett.95:142501,2005
We report the present results of CUORICINO a cryogenic experiment on neutrinoless double beta decay (DBD) of 130Te consisting of an array of 62 crystals of TeO2 with a total active mass of 40.7 kg. The array is framed inside of a dilution refrigerato
Externí odkaz:
http://arxiv.org/abs/hep-ex/0501034
Publikováno v:
Rev. Sci. Instrum. 76, 023902 (2005)
We present the design and construction of a SQUID-based magnetometer for operation down to temperatures T = 10 mK, while retaining the compatibility with the sample holders typically used in commercial SQUID magnetometers. The system is based on a dc
Externí odkaz:
http://arxiv.org/abs/physics/0406098
Autor:
Arnaboldi, C., Avignone III, F. T., Beeman, J., Barucci, M., Balata, M., Brofferio, C., Bucci, C., Cebrian, S., Creswick, R. J., Capelli, S., Carbone, L., Cremonesi, O., de Ward, A., Fiorini, E., Farach, H. A., Frossati, G., Giuliani, A., Giugni, D., Gorla, P., Haller, E. E., Irastorza, I. G., McDonald, R. J., Morales, A., Norman, E. B., Negri, P., Nucciotti, A., Pedretti, M., Pobes, C., Palmieri, V., Pavan, M., Pessina, G., Pirro, S., Previtali, E., Rosenfeld, C., Smith, A. R., Sisti, M., Ventura, G., Vanzini, M., Zanotti, L.
Publikováno v:
Nucl.Instrum.Meth.A518:775-798,2004
CUORE is a proposed tightly packed array of 1000 TeO2 bolometers, each being a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical towers, arranged in a square of 5 towers by 5 towers, each containing 10 layers of 4 crystals.
Externí odkaz:
http://arxiv.org/abs/hep-ex/0212053
Autor:
Albada, D. v., Amersfoort, W. v., Rookhuizen, H. Boer, Flokstra, J., Frossati, G., Graaf, H. v. d., Heijboer, A., Heijboer, G., Heuvel, E. v. d., Holten, J. W. v., Nooren, G. J., Oberski, J., Rogalla, H., de Waele, A., Huberts, P. de Witt
A cryogenic spherical and omni-directional resonant-mass detector proposed by the GRAIL collaboration is described.
Comment: 5 pages, 4 figs., contribution to proceedings GW Data Analysis Workshop, Paris, nov. 1997
Comment: 5 pages, 4 figs., contribution to proceedings GW Data Analysis Workshop, Paris, nov. 1997
Externí odkaz:
http://arxiv.org/abs/gr-qc/9804073
Publikováno v:
Phys.Rev.D57:2051-2060,1998
The most important features of the proposed spherical gravitational wave detectors are closely linked with their symmetry. Hollow spheres share this property with solid ones, considered in the literature so far, and constitute an interesting alternat
Externí odkaz:
http://arxiv.org/abs/gr-qc/9707059