Zobrazeno 1 - 10
of 61
pro vyhledávání: '"Frederic Van Heuverswyn"'
Publikováno v:
Frontiers in Cardiovascular Medicine, Vol 9 (2022)
Left bundle branch area pacing (LBBAP) has emerged as a novel pacing modality which aims to capture the left bundle branch area and avoids the detrimental effects of right ventricular pacing. Current approaches for LBBAP have been developed using lum
Externí odkaz:
https://doaj.org/article/7f351b5f05774d43885c00b71a485616
Autor:
Tom Jackson, Radoslaw Lenarczyk, Maciej Sterlinski, Adam Sokal, Darrell Francis, Zachary Whinnett, Frederic Van Heuverswyn, Marc Vanderheyden, Joeri Heynens, Berthold Stegemann, Richard Cornelussen, Christopher Aldo Rinaldi
Publikováno v:
International Journal of Cardiology: Heart & Vasculature, Vol 19, Iss , Pp 14-19 (2018)
Background: We sought to determine whether presence, amount and distribution of scar impacts the degree of acute hemodynamic response (AHR) with multisite pacing.Multi-vein pacing (MVP) or multipolar pacing (MPP) with a multi-electrode left ventricul
Externí odkaz:
https://doaj.org/article/a5ae31c7f51847ceabc3f4c898bc8821
Autor:
Frederic Van Heuverswyn, MD, Marc De Buyzere, MSc, Mathieu Coeman, MD, Jan De Pooter, PhD, Benny Drieghe, MD, Mattias Duytschaever, PhD, Sofie Gevaert, PhD, Peter Kayaert, MD, Yves Vandekerckhove, MD, Joeri Voet, MD, Milad El Haddad, PhD, Peter Gheeraert, PhD
Publikováno v:
The Lancet: Digital Health, Vol 1, Iss 2, Pp e90-e99 (2019)
Summary: Background: Time delay between onset of symptoms and seeking medical attention is a major determinant of mortality and morbidity in patients with acute coronary artery occlusion. Response time might be reduced by reliable self-detection. We
Externí odkaz:
https://doaj.org/article/baf891836b2443a5b958b2d97be09c6d
Autor:
Maciej Sterliński, Adam Sokal, Radosław Lenarczyk, Frederic Van Heuverswyn, C Aldo Rinaldi, Marc Vanderheyden, Vladimir Khalameizer, Darrel Francis, Joeri Heynens, Berthold Stegemann, Richard Cornelussen
Publikováno v:
PLoS ONE, Vol 11, Iss 4, p e0154024 (2016)
Recent efforts to increase CRT response by multiSPOT pacing (MSP) from multiple bipols on the same left ventricular lead are still inconclusive.The Left Ventricular (LV) MultiSPOTpacing for CRT (iSPOT) study compared the acute hemodynamic response of
Externí odkaz:
https://doaj.org/article/8c4e87fbbf5141df91d53f86ed8b8b45
Autor:
Jan De Pooter, Emine Ozpak, Simon Calle, Peter Peytchev, Ward Heggermont, Sebastien Marchandise, Frank Provenier, Bart Francois, Wim Anné, Peter Pollet, Cynthia Barbraud, Kris Gillis, Frank Timmermans, Frederic Van Heuverswyn, Roderick Tung, Aurélien Wauters, Jean‐Benoit le Polain de Waroux
Publikováno v:
Journal of cardiovascular electrophysiology, Vol. 33, no.7, p. 1540-1549 (2022)
Left bundle branch area pacing (LBBAP) has been performed exclusively using lumen-less pacing leads (LLL) with fixed helix design. This registry study explores the safety and feasibility of LBBAP using stylet-driven leads (SDL) with extendable helix
Autor:
Emine Özpak, Johan De Vriese, Frederic Van Heuverswyn, Frank Timmermans, Haran Burri, Jan De Pooter
Publikováno v:
Journal of cardiovascular electrophysiology.
A 67-year old female patient with non-ischemic cardiomyopathy and wide (180ms) left bundle branch block (LBBB) and reduced ejection fraction (EF)35% despite optimal medical treatment was referred for cardiac resynchronization therapy (CRT) This artic
Publikováno v:
Journal of Cardiovascular Electrophysiology. 32:439-448
Introduction Left bundle branch area pacing (LBBAP) aims to achieve physiological pacing by capturing the conduction system in the area of the left bundle branch. LBBAP has exclusively been performed using lumen-less pacing leads (LLLs) with fixed he
Publikováno v:
Journal of Cardiovascular Electrophysiology. 31:1844-1847
His bundle pacing (HBP) offers physiologic pacing by placing the pacing lead directly to the His bundle. We present a case in which a HBP lead, implanted at the fragile membranous septum, resulted in a persistent restrictive perimembranous ventricula
Autor:
Tine Philipsen, Frederic Van Heuverswyn, Jan De Pooter, Peter Gheeraert, Sofie Gevaert, Mathieu Coeman, Liesbeth Timmers, Peter Kayaert, Simon Calle, Jens Czapla
Publikováno v:
Journal of Electrocardiology. 59:68-73
New onset electrocardiographic (ECG) changes after transcatheter aortic valve replacement (TAVR) are used to assess the risk for late atrioventricular block. However, the time of ECG evaluation remains controversial. We aimed to compare the time cour
Autor:
Frederic Van Heuverswyn, Céline De Schepper, Marc De Buyzere, Mathieu Coeman, Jan De Pooter, Benny Drieghe, Peter Kayaert, Liesbeth Timmers, Sofie Gevaert, Simon Calle, Victor Kamoen, Anthony Demolder, Milad El Haddad, Peter Gheeraert
Publikováno v:
EUROPEAN HEART JOURNAL DIGITAL HEALTH
AimsIn this study, we compare the diagnostic accuracy of a standard 12-lead electrocardiogram (ECG) with a novel 13-lead ECG derived from a self-applicable 3-lead ECG recorded with the right exploratory left foot (RELF) device. The 13th lead is a nov
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b2061be204cfc37aeb529515c494fdcd
https://biblio.ugent.be/publication/01GTEYBWRWQXQFHYABYFXD7FN4/file/01GTEYJY52TQKJQWC7HS1Q1FDB
https://biblio.ugent.be/publication/01GTEYBWRWQXQFHYABYFXD7FN4/file/01GTEYJY52TQKJQWC7HS1Q1FDB