Zobrazeno 1 - 10
of 29
pro vyhledávání: '"Fred Steennis"'
Publikováno v:
Energies, Vol 12, Iss 7, p 1405 (2019)
Contactless capacitive (open-air) sensors are applied to monitor overvoltages near overhead line terminations at a substation or at the transition from underground cables to overhead lines. It is shown that these sensors, applied in a differentiating
Externí odkaz:
https://doaj.org/article/3575955a9a61425a942be92e84288783
Publikováno v:
Proceedings of the Nordic Insulation Symposium. :70-75
Contactless capacitive sensors are applied to monitor(over)voltages near the overhead line terminations of asubstation or at cable to line transitions. The sensor response isthe signal time derivative when loaded with a resistiveimpedance and the wav
Publikováno v:
IEEE Transactions on Power Delivery, 34(4):8662604, 1423-1431. Institute of Electrical and Electronics Engineers
The low-voltage distribution grid is an essential link for the integration of distributed renewable sources. It is expected to experience stronger loading and load variation in the near future. At the same time, part of the low-voltage network is an
Publikováno v:
IEEE Transactions on Power Delivery, 34(2):8492437, 532-541. Institute of Electrical and Electronics Engineers
The increasing utilization of HVAC underground power cables gives rise to technical challenges related to the occurrence of electromagnetic transients. This paper discusses measurements with sensors based on open air capacitances sensing the electric
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::854db533724a6e99c25b3934418400d4
https://research.tue.nl/nl/publications/03c1a9b5-7d35-4fdf-b93c-5bafcdfae77f
https://research.tue.nl/nl/publications/03c1a9b5-7d35-4fdf-b93c-5bafcdfae77f
Publikováno v:
Energies, 12(7):1405. Multidisciplinary Digital Publishing Institute (MDPI)
Energies
Volume 12
Issue 7
Energies, Vol 12, Iss 7, p 1405 (2019)
Energies
Volume 12
Issue 7
Energies, Vol 12, Iss 7, p 1405 (2019)
Contactless capacitive (open-air) sensors are applied to monitor overvoltages near overhead line terminations at a substation or at the transition from underground cables to overhead lines. It is shown that these sensors, applied in a differentiating
Autor:
Tjeerd Broersma, Denny Harmsen, P. Wagenaars, Peter C. J. M. van der Wielen, Pascal Bleeker, Fred Steennis, P.A.A.F. Wouters, Y. Li
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation, 23(3), 1562-1569. Institute of Electrical and Electronics Engineers
On-line partial discharge (PD) detection and location has proven to be a valuable tool for assessing the condition of medium-voltage (MV) power cables in service. A few advances are discussed in this paper. It is of importance to know all factors aff
Autor:
P. Wagenaars, G. Hoogendorp, Marjan Popov, Lou van der Sluis, P.A.A.F. Wouters, E. Fred Steennis, Jos J. de Regt
Publikováno v:
IET Science, Measurement & Technology, 9(3), 268-275. Institution of Engineering and Technology (IET)
IET Science, Measurement and Technology, 2014
IET Science, Measurement and Technology, 2014
Transients from lightning strikes can enter underground cables at overhead line to power cable transitions. Possible overvoltages on these surges at cross-bonding connections of the cable screens are of major concern. A model is developed for modelli
Publikováno v:
2016 IEEE International Energy Conference (ENERGYCON)
Transmission system limits, originating from right-of-way permission processes for new corridors, can be surpassed by erecting new circuits in close proximity, or even on common structures. Especially for long distance bulk power transfer, high volta
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::1ccf452dda1a68253bf84a59cc9a237b
http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-191152
http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-191152
Publikováno v:
Proceedings of 2015 IEEE PowerTech Eindhoven. 29 June-2 July, Eindhoven, The Netherlands, 1-6
STARTPAGE=1;ENDPAGE=6;TITLE=Proceedings of 2015 IEEE PowerTech Eindhoven. 29 June-2 July, Eindhoven, The Netherlands
STARTPAGE=1;ENDPAGE=6;TITLE=Proceedings of 2015 IEEE PowerTech Eindhoven. 29 June-2 July, Eindhoven, The Netherlands
Underground power cables are increasingly employed to transfer electricity. In the Netherlands, all medium-voltage (MV) and low-voltage (LV) networks are realized with underground power cables. Consequently, power cable diagnostic has became a releva
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d11a3a98cbfb7857e3a5ee20d72482df
https://doi.org/10.1109/ptc.2015.7232769
https://doi.org/10.1109/ptc.2015.7232769
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation, 22(2), 665-672. Institute of Electrical and Electronics Engineers
Insulation temperature is the critical parameter for dynamic rating of underground power cables. Power cables on medium voltage (MV) level are too numerous and widespread to economically justify solutions like optical fibers as temperature sensors, o
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e5526cae2c2ad33c5e9d8b2160f33f2a
https://research.tue.nl/nl/publications/2e92a976-b201-492a-88c5-d91448995870
https://research.tue.nl/nl/publications/2e92a976-b201-492a-88c5-d91448995870