Zobrazeno 1 - 6
of 6
pro vyhledávání: '"Frank N. Slachman"'
Autor:
Frank N. Slachman, Kenneth Herskowitz, Jonathan D. Hoffberger, Gary Grosner, James E. Davies, Paul L. DiGiorgi, S. Chris Malaisrie, Mubashir A. Mumtaz, Kevin D. Accola, Romualdo J. Segurola
Publikováno v:
The Annals of Thoracic Surgery. 109:1289-1293
Purpose The Edwards Intuity Elite (EIE; Edwards Lifesciences, Irvine, CA) valve system is a recent surgical aortic valve designed to expedite implantation, facilitate minimally invasive approaches, and provide low gradients, particularly in smaller v
Autor:
Frank N. Slachman, Eugene A. Grossi, Himanshu J. Patel, Mubashir Mumtaz, W. Randolph Chitwood, Matthew A. Romano, Michael S. Koeckert, Glenn R. Barnhart
Publikováno v:
The Annals of Thoracic Surgery. 106:685-690
Background Expandable, rapid deployment aortic valves may interfere with the cardiac conduction system, which can lead to permanent pacemaker implantation (PPI). We sought to characterize PPI after rapid deployment aortic valve replacement with the E
Autor:
Michael A. Borger, Francis G. Duhay, Kevin D. Accola, Frank N. Slachman, Glenn R. Barnhart, W. Randolph Chitwood, Himanshu J. Patel, Mubashir Mumtaz, Y. Joseph Woo, Patrick M. McCarthy, Evelio Rodriguez, William H. Ryan, Eugene A. Grossi, Michael J. Mack, H. Edward Garrett, Joseph F. Sabik
Publikováno v:
The Journal of Thoracic and Cardiovascular Surgery.
BackgroundThe TRANSFORM (Multicenter Experience With Rapid Deployment Edwards INTUITY Valve System for Aortic Valve Replacement) trial (NCT01700439) evaluated the performance of the INTUITY rapid deployment aortic valve replacement (RDAVR) system in
Autor:
Frank N. Slachman
Publikováno v:
The Annals of Thoracic Surgery. 97:e129-e131
An acellular, noncrosslinked, extracellular-matrix bioscaffold patch was used for aortic root reconstruction after aortic valve replacement in a 90-year-old woman. After her death 3 years later, histologic examination showed constructive remodeling a
Autor:
Frank N. Slachman
Publikováno v:
Heart, Lung and Circulation. 24:e40
was repaired with a pericardial patch and the posterior leaflet reattached to the neo-annulus (made of pericardium and left atrium). The remaining leaflet tissue was augmented with pericardium and a 32 mm Physio II (CarpentierEdwards) annuloplasty ri
Publikováno v:
Journal of cardiothoracic and vascular anesthesia. 7(4)
The purpose of this study was to determine if clonidine reduces myocardial ischemia or alters anesthetic requirement and perioperative hemodynamic parameters during coronary artery bypass grafting (CABG) surgery. Forty-three patients were randomized