Bryan M. Wimer, Erik W. Sinsel, Christopher Warren, Frank L. Buczek, John Z. Wu, Daniel S Gloekler
Publikováno v:
Medical Engineering & Physics. 38:72-79
Inverse dynamics models used to investigate musculoskeletal disorders associated with handle gripping require accurate phalangeal kinetics. Cylindrical handles wrapped with pressure film grids have been used in studies of gripping kinetics. We presen
Autor:
Frank L. Buczek, Kristin D. Zhao, Daniel E. Welcome, Erik W. Sinsel, Christopher Warren, Justin F. Shroyer, John Z. Wu, Kai Nan An
Publikováno v:
Journal of Biomechanics. 47:392-399
Previous epidemiological studies indicate that the use of thumb-push mechanical pipettes is associated with musculoskeletal disorders (MSDs) in the hand. The goal of the current study was to analyze the loading in the muscle–tendon units in the thu
Autor:
Kristin D. Zhao, Erik W. Sinsel, Frank L. Buczek, Bryan M. Wimer, Kai Nan An, John Z. Wu, Daniel S. Gloekler
Publikováno v:
Medical Engineering & Physics. 34:693-701
Thumb-push manual pipettes are commonly used tools in many medical, biological, and chemical laboratories. Epidemiological studies indicate that the use of thumb-push mechanical pipettes is associated with musculoskeletal disorders in the hand. The g
Publikováno v:
Gait & Posture. 35:529-534
Kinematic multi-segment foot models are still evolving, but have seen increased use in clinical and research settings. The addition of kinetics may increase knowledge of foot and ankle function as well as influence multi-segment foot model evolution;
Publikováno v:
Clinical Biomechanics. 23:1299-1302
Background Conventional motion analysis studies define the ankle joint center as the midpoint between the most medial and lateral aspects of the malleoli, yet research points toward a more distal joint center location. The purpose of this study was t
Publikováno v:
Journal of Biomechanical Engineering. 137
Dynamic loading on articular joints is essential for the evaluation of the risk of the articulation degeneration associated with occupational activities. In the current study, we analyzed the dynamic constraint loading for the thumb during pipetting.
Autor:
Anne Schmitz, Kevin M. Cooney, Darryl G. Thelen, Michael J. Rainbow, Frank L. Buczek, Dustin A. Bruening
Publikováno v:
Computer methods in biomechanics and biomedical engineering. 19(2)
The objective of this study was to determine how marker spacing, noise, and joint translations affect joint angle calculations using both a hierarchical and a six degrees-of-freedom (6DoF) marker set. A simple two-segment model demonstrates that a hi
Publikováno v:
Gait & Posture. 23:519-522
MacWilliams et al. report their progress on a multi-segment foot model, including mediolateral segmentation, from which they calculate kinematics and kinetics [MacWilliams BA, Cowley M, Nicholson DE. Foot kinematics and kinetics during adolescent gai
Publikováno v:
Clinical Biomechanics. 21:59-66
Children with cerebral palsy and hamstring tightness often demonstrate limited terminal swing knee extension. The conventional clinical measure of popliteal angle describes static hamstring tightness, but is not consistent with dynamic limitation. We
Publikováno v:
Physiotherapy Research International. 10:10-22
Background and Purpose. People with vestibular dysfunction experience dizziness, vertigo and postural instability. The persistence of these symptoms may result in decreased balance confidence. The purpose of the present study was to examine the relat