Zobrazeno 1 - 10
of 53
pro vyhledávání: '"Francis W, Cooke"'
Publikováno v:
Journal of Orthopaedic Research. 28:767-772
The effects of osteophyte debridement, bony cuts, and soft tissue releases on the functional flexion axis of the knee can be assessed by evaluating 3D kinematics following each step of a total knee arthroplasty. Using a navigated knee system with ded
Publikováno v:
The Journal of Arthroplasty. 20:72-78
The irretrievably failed total knee arthroplasty is the primary indication for knee arthrodesis. Because this difficult condition is relatively rare, an intramedullary arthrodesis system was developed which requires minimal surgeon experience for suc
Publikováno v:
The Journal of Bone and Joint Surgery-American Volume. 85:58-62
Revision total knee arthroplasty for aseptic loosening or following infection can pose formidable challenges to the reconstructive surgeon. In some cases, the patient will undergo a series of operations, each resulting in ever-increasing bone loss. I
Publikováno v:
American journal of orthopedics (Belle Mead, N.J.). 41(12)
We evaluated the stability of locking and nonlocking plate fixation of the pubic symphysis in a cadaveric model of an unstable pelvic injury. Five fresh cadaver pelves--intact and with an unfixed simulated Tile B injury--were tested under compressive
A PRIMER OF BIOMECHANICS is the first volume of its kind to present the principles of biomechanics with a highly clinical orientation. Dr. Lucas and his colleagues (specialists in biomechanics) have assembled a practical guide utilizing case presenta
Publikováno v:
American journal of orthopedics (Belle Mead, N.J.). 40(2)
Locking plates are well suited to complex fracture patterns and weak bone. In the study reported here, we compared the structural stability of 3 different locking compression plate (LCP) constructs using composite analogue humeri. Eighteen analogue c
Autor:
Ryan W, Livermore, Alexander C M, Chong, Daniel J, Prohaska, Francis W, Cooke, Teresa L, Jones
Publikováno v:
American journal of orthopedics (Belle Mead, N.J.). 39(12)
In the study described here, we evaluated load to failure and cyclic loading elongation of different braided polyblend sutures under different sliding knot configurations. Four braided polyblend sutures (FiberWire, Herculine, Orthocord, Ultrabraid) w
A finite element model for predicting the effect of fiber bridging, fiber properties, and fiber-matrix interface strength on the crack-tip stresses and crack propagation potential of a chopped-fiber composite is proposed.The method of virtual crack e
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::b4f225b2be70feedff4f677d1d054a7e
https://doi.org/10.1520/stp19937s
https://doi.org/10.1520/stp19937s
Publikováno v:
The Journal of Bone & Joint Surgery. 73:726-733
We created unstable intertrochanteric fractures with a large posteromedial defect in eighteen pairs of fresh-frozen femora from cadavera, and used the femora to evaluate the stability of six combinations of treatment with sliding compression screws a
Publikováno v:
Journal of Biomedical Materials Research. 24:591-604
An elastic stress analysis of porous-coated implant surfaces was performed using the finite element method. Three-hundred-microns-diameter metal beads sinter bonded onto an implant surface were modeled with sinter neck radii of 5, 10, 20, and 50 micr