Zobrazeno 1 - 10
of 35
pro vyhledávání: '"Francesco Naddeo"'
Publikováno v:
Heliyon, Vol 10, Iss 4, Pp e26334- (2024)
Background and objective: Many diseases of the spine require surgical treatments that are currently performed based on the experience of the surgeon. The basis of this study is to deliver an automatic and patient-specific algorithm able to come to th
Externí odkaz:
https://doaj.org/article/7bbdd7caf058480d8f27b730a83dd460
Publikováno v:
Applied Sciences, Vol 10, Iss 17, p 5977 (2020)
The most common type of spine instrumentation is the pedicle screw fixation. The recent literature shows how customized drilling templates help surgeons to perform the surgery better. This work aims to validate the design of a customized template for
Externí odkaz:
https://doaj.org/article/2635a45831a742d38238514738e38037
Publikováno v:
Symmetry, Vol 10, Iss 8, p 334 (2018)
In this article, the authors propose a novel procedure for designing a customized 3D-printed surgical template to guide surgeons in inserting screws into the sacral zone during arthrodesis surgeries. The template is characterized by two cylindrical g
Externí odkaz:
https://doaj.org/article/4ea5152d593c44e9a23d2bddafb34da7
Autor:
Francesco Naddeo, Carlos Julio Cortés-Rodríguez, Nicola Cappetti, Antonio Emmanuele Uva, Alessandro Naddeo, Giuseppe Monno, Antonio Boccaccio, Michele Fiorentino, Óscar L. Rodríguez-Montaño, Michele Gattullo
Publikováno v:
ACS biomaterials scienceengineering. 5(10)
By combining load adaptive algorithms with mechanobiological algorithms, a computational framework was developed to design and optimize the microarchitecture of irregular load adapted scaffolds for bone tissue engineering. Skeletonized cancellous bon
Publikováno v:
Applied Sciences
Volume 10
Issue 17
Applied Sciences, Vol 10, Iss 5977, p 5977 (2020)
Volume 10
Issue 17
Applied Sciences, Vol 10, Iss 5977, p 5977 (2020)
The most common type of spine instrumentation is the pedicle screw fixation. The recent literature shows how customized drilling templates help surgeons to perform the surgery better. This work aims to validate the design of a customized template for
Autor:
Rita C. Assunção-Silva, Carlo Alberto Benech, Mauro Bergui, Leonardo Boccaccini, Beatrice Boido, Giovanni Boniolo, Fernando Carpanese, Tommaso Casalini, Armando Cioffi, Alessandra Di Liberto, Marilena Ferraris, Bruno Ferrero, Mario Gimona, Eduardo D. Gomes, Antonio González-Cantalapiedra, Mozhdeh Imaninezhad, Šárka Kubinová, Rui Lima, Mónica López-Peña, Maurizio Masi, Emanuele Mauri, Fano Molinaro, Giulia Morbidoni, Fernando María Muñoz Guzón, Francesco Naddeo, Simonetta Papa, Giuseppe Perale, Rosa Perez, María Permuy, Gianni Pertici, Michael Reinert, Andrea De Rinaldis, Luís A. Rocha, Filippo Rossi, Raúl E. Russo, António J. Salgado, Virginia Sanchini, Saahil Sheth, N.A. Silva, Alberto Tomatis, Pietro Veglianese, Irma Vismara, Domenico Zaca’, Pier Luigi La Zazzera, Silviya Petrova Zustiak
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::1cba3ebcbb9bdcc014af1881f2f1ed2b
https://doi.org/10.1016/b978-0-08-102807-0.01002-4
https://doi.org/10.1016/b978-0-08-102807-0.01002-4
Autor:
Leonardo Boccaccini, Francesco Naddeo, Armando Cioffi, Fernando Carpanese, Mauro Bergui, Andrea De Rinaldis, Giulia Morbidoni, Marilena Ferraris, Fano Molinaro, Domenico Zaca, Pier Luigi La Zazzera
Magnetic resonance imaging (MRI) is the state-of-the-art radiological tool used to visualize the spinal cord in both normal and pathological conditions. MRI enables visualization in nearly real time (within minutes), with submillimetric spatial resol
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::6c593083819ae424bc32caf67c3ee71b
https://doi.org/10.1016/b978-0-08-102807-0.00004-1
https://doi.org/10.1016/b978-0-08-102807-0.00004-1
Publikováno v:
Composites Part B: Engineering. 115:51-59
This work deals with the development, the application and the experimental validation of a procedure based on an algorithm, running in a finite element environment replacing the continuous mass of convex solids with a cancellous bone-inspired lattice
Publikováno v:
Composites Part B: Engineering. 115:60-69
This work shows the practical application and the experimental validation of a procedure based on an algorithm, running in a finite element environment, able to operate inside a convex three-dimensional solid by replacing the continuous mass with an
Autor:
Francesco Naddeo, Carlotta Fontana, Emilio Cataldo, Nicola Cappetti, Nicola Narciso, Alessandro Naddeo
Publikováno v:
The international journal of medical robotics + computer assisted surgery : MRCAS. 15(4)
BACKGROUND The integration of computer-aided design/computer-aided manufacturing (CAD/CAM) tools and medicine is rapidly developing for designing medical devices. A novel design for a 3D-printed patient-specific surgical template for thoracic pedicle