Autor:
Mauro Panteghini, Mario Toppino, Paolo Hoffer, Gianmatteo Micca, Giancarlo Zucchelli, Luigi Romano, Franca Pagani, Fabio Manoni, Francesca Stefini, Annalisa Iervasi, Romolo M. Dorizzi, Marco Caputo
Publikováno v:
Clinical Chemistry. 50:1707-1709
The redefined biochemical criterion proposed to diagnose myocardial infarction (MI) necessitates the availability of highly sensitive and precise cardiac troponin assays (1). In general, a substantial improvement in the analytical performance is offe
Autor:
Mauro Panteghini, Raffaele Giubbini, Graziella Bonetti, Franca Pagani, Francesca Stefini, Claudio Cuccia
Publikováno v:
Clinical Chemistry and Laboratory Medicine (CCLM). 43
Few studies have evaluated cardiac troponin I (cTnI) as a marker for infarct size and left ventricular (LV) dysfunction. Here we investigated the ability of a single-point cTnI, measured with a second-generation assay (Access AccuTnI), to estimate in
Publikováno v:
Clinical chemistry. 50(7)
Cardiac troponin has been designated as the preferred biomarker for diagnosis of myocardial infarction (MI) (1). Previously published data, however, confirm the large diversity among cardiac troponin assays with respect to important analytical charac
Autor:
Jean-Paul Chapelle, Jutta Engelmayer, Franca Pagani, Mauro Panteghini, Hilmar Luthe, Francesca Stefini, Guillaume Lefevre, Hanafi Graine
Publikováno v:
Clinical biochemistry. 37(9)
Objectives: This study evaluated the analytical characteristics of the LiaisonR immunoassay for cardiac troponin I (cTnI). Design and methods: The protocol consisted of eight sections: evaluation of antibody specificity, linearity, detection limit an
Publikováno v:
Clinical chemistry and laboratory medicine. 38(11)
The measurement of the degradation product of the C-telopeptide of type I collagen in serum (s-βCTX) has been evaluated in the form of an automated chemiluminometric assay. The between-day coefficients of variation ranged between 2.6 and 6.0% over t
Publikováno v:
Clinical chemistry. 46(7)
The ACS:180® immunoassay system (Bayer Diagnostics) is an automated random analyzer that uses acridinium ester-based chemiluminescence detection. The architecture of the cardiac marker assays is a heterologous sandwich format, using monoclonal anti-
Publikováno v:
Clinical Chemistry and Laboratory Medicine. 38
The availability of specific markers of myocardial damage has focused attention on the decision limits to be used in clinical practice. These markers can be employed in the diagnosis of myocardial infarction and risk stratification in patients with a