Zobrazeno 1 - 10
of 47
pro vyhledávání: '"Flavio Marchetto"'
Autor:
Abdolkazem Ansarinejad, Marco Donetti, Maria Adelaide Garella, Simona Giordanengo, Roberto Cirio, Flavio Marchetto, Vincenzo Monaco, Cristiana Peroni, Roberto Sacchi
Publikováno v:
Iranian Journal of Medical Physics, Vol 9, Iss 4, Pp 225-232 (2013)
Introduction Hadron-therapy is an effective technique used to treat tumors that are located between or nearby vital organs. The Italian National Center of Oncological Hadron-therapy (CNAO) has been realized as the first facility in Italy to treat ver
Externí odkaz:
https://doaj.org/article/1998417d855042c7995b48b9bfb5bda3
Publikováno v:
Integrated Environmental Assessment and Management. 18:1020-1034
European Pesticide Registration requires a risk assessment (RA) for nontarget organisms according to EU Regulation. European Authorities have developed Guidance Documents (GDs) for RA considering exposure scenarios for the required organisms typical
Autor:
Michal Zamkovský, Riccardo Aliberti, F. Ambrosino, Roberto Ammendola, Bruno ANGELUCCI, A. Antonelli, G Anzivino, Roberta Arcidiacono, T. Bache, Aigul Baeva, D. Baigarashev, M. Barbanera, J. Bernhard, A. Biagioni, Lubos Bician, Cristina Biino, Andrea Bizzeti, T. Blazek, Brigitte BlochDevaux, V. Bonaiuto, M. Boretto, M. Bragadireanu, D. Britton, Francesco Brizioli, M.B. Brunetti, D. Bryman, Francesca Bucci, Tiziana Capussela, J. Carmignani, Augusto Ceccucci, P. Cenci, V. Cerny, C. Cerri, B. Checcucci, A. Conovaloff, P. Cooper, Eduardo Cortina Gil, M. Corvino, F. Costantini, Angelo Cotta Ramusino, A. Coward, G. D’Agostini, John Dainton, P. Dalpiaz, Hans Danielsson, N. De Simone, D. Di Filippo, Luigi Di Lella, Niels Doble, Babette Dobrich, F. Duval, V. Duk, D. Emelyanov, Jurgen Engelfried, T. Enik, Nora Estrada-Tristan, Valeri Falaleev, R. Fantechi, V. Fascianelli, Luca Federici, S. Fedotov, Alessandra Filippi, Massimiliano Fiorini, J. Fry, J. Fu, Adolfo Fucci, L. Fulton, Enrico Gamberini, Lau Gatignon, G. Georgiev, S. Ghinescu, Alberto Gianoli, M. Giorgi, Sergio Giudici, Francesco Gonnella, Evgueni Goudzovski, C. Graham, Roberto Guida, Evgeny Gushchin, F. Hahn, H. Heath, J. Henshaw, E.B. Holzer, Tomas Husek, O. Hutanu, D. Hutchcroft, L. Iacobuzio, Enrico Iacopini, Ermanno Imbergamo, B. Jenninger, Jan Jerhot, R.W. Jones, K. Kampf, Vladimir Kekelidze, Sergei Kholodenko, G. Khoriauli, A. Khotyantsev, Alina Kleimenova, A. Korotkova, Michal Koval, Venelin Kozhuharov, Zuzana Kucerova, Y. Kudenko, J. Kunze, V. Kurochka, V. Kurshetsov, Gaia Lanfranchi, Gianluca Lamanna, E. Lari, G. Latino, Paul Laycock, Cristina Lazzeroni, M. Lenti, G. Lehmann Miotto, E. Leonardi, P. Lichard, Leandar Litov, R. Lollini, D. Lomidze, Alessandro Lonardo, Pasquale Lubrano, Matteo Lupi, N. Lurkin, Dmitry Madigozhin, I. Mannelli, Alessandro Mapelli, Flavio Marchetto, Radoslav Marchevski, S. Martellotti, Paolo Massarotti, Karim Massri, E. Maurice, M. Medvedeva, A. Mefodev, E. Menichetti, Ernesto Migliore, E. Minucci, M. Mirra, M. Misheva, Natalia Molokanova, Matthew Moulson, S. Movchan, M. Napolitano, I. Neri, F. Newson, Alan Norton, Matthew Noy, Toshio Numao, Vladimir Obraztsov, A. Ostankov, S. Padolski, R. Page, V. Palladino, A. Parenti, Chris John Parkinson, E. Pedreschi, Monica Pepe, M. Perrin-Terrin, L. Peruzzo, P. Petrov, Y. Petrov, Ferruccio Petrucci, Roberto Piandani, M. Piccini, Jacopo Pinzino, I. Polenkevich, L. Pontisso, Yuri Potrebenikov, D. Protopopescu, Mauro Raggi, Angela Romano, P. Rubin, Giuseppe Ruggiero, Vladimir Ryjov, A. Salamon, C. Santoni, G. Saracino, F. Sargeni, S. Schuchmann, Vitali Semenov, Antonino Sergi, A. Shaikhiev, Sergey Shkarovskiy, D. Soldi, V. Sugonyaev, M. Sozzi, T. Spadaro, F. Spinella, A. Sturgess, Joel Swallow, Stoyan Miroslavov Trilov, Paolo Valente, Bob Velghe, Stefano Venditti, P. Vicini, Roberta Volpe, M. Vormstein, Heinrich Wahl, Rainer Wanke, B. Wrona, O. Yushchenko, A. Zinchenko
The decay $K^+\to\pi^+\nu\bar{\nu}$, with a very precisely predicted branching ratio of less than $10^{-10}$, is among the best processes to reveal indirect effects of new physics. The NA62 experiment at CERN SPS is designed to study the $K^+\to\pi^+
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::82d5ad23b9367c30b60c1f16c371bc9d
http://cds.cern.ch/record/2861345
http://cds.cern.ch/record/2861345
Autor:
A Vignati, Mohammad Amin Hosseini, Marco Donetti, Roberto Sacchi, Vincenzo Monaco, Simona Giordanengo, Roberto Cirio, Flavio Marchetto, Andrea Attili, F.M. Milian, G. V. Russo, Mario Ciocca
Purpose A retrospective analysis of the dose delivery system (DDS) performances of the initial clinical operation at CNAO (Centro Nazionale di Adroterapia Oncologica) is reported, and compared with the dose delivery accuracy following the implementat
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a6aeba68e3957f7bace03c0461dbe36f
http://hdl.handle.net/2318/1757601
http://hdl.handle.net/2318/1757601
The NA62 GigaTracKer: a low mass high intensity beam 4D tracker with 65 ps time resolution on tracks
Autor:
Roberto Malaguti, E. Cortina Gil, B. Velghe, M. Morel, K. Poltorak, E. Gamberini, Fabrizio Petrucci, Augusto Ceccucci, Roberta Arcidiacono, H. Wahl, Luca Federici, G. Aglieri Rinella, S. Chiozzi, A. Kleimenova, Flavio Marchetto, Massimiliano Fiorini, G. Nuessle, D. Alvarez Feito, A. Gianoli, J. Noël, J. Degrange, J. Kaplon, Cristina Biino, E. Martin Albarran, H. O. Danielsson, M. Perrin-Terrin, A. Mapelli, L. Perktold, A. Cotta Ramusino, Matthew Noy, P. Petagna, Giuseppe Ruggiero, G. Romagnoli, S. Bonacini, E. Minucci, Alexander Kluge, Ernesto Migliore
Publikováno v:
JINST
JINST, 2019, 14, pp.P07010. ⟨10.1088/1748-0221/14/07/P07010⟩
Journal of Instrumentation
Journal of Instrumentation, IOP Publishing, 2019, 14, pp.P07010. ⟨10.1088/1748-0221/14/07/P07010⟩
JINST, 2019, 14, pp.P07010. ⟨10.1088/1748-0221/14/07/P07010⟩
Journal of Instrumentation
Journal of Instrumentation, IOP Publishing, 2019, 14, pp.P07010. ⟨10.1088/1748-0221/14/07/P07010⟩
International audience; The GigaTracKer (GTK) is the beam spectrometer of the CERN NA62 experiment. The detector features challenging design specifications, in particular a peak particle flux reaching up to 2.0 MHz/mm$^2$, a single hit time resolutio
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::2011fccff7929f0d092544cc39188c17
https://hal.archives-ouvertes.fr/hal-02411224
https://hal.archives-ouvertes.fr/hal-02411224
Autor:
Vincenzo Monaco, M. Donetti, Flavio Marchetto, Mohammad Amin Hosseini, M. A. Garella, Cristiana Peroni, Alfredo Mirandola, Mario Ciocca, Roberto Sacchi, Simona Giordanengo, F. Bourhaleb, Roberto Cirio
Publikováno v:
Medical Physics. 42:263-275
Purpose: This paper describes the system for the dose delivery currently used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. Methods: CNAO Foundation, Istituto Nazionale di Fisica Nucleare and U
Autor:
A. Vignati, Simona Giordanengo, Roberto Sacchi, F. Mas Milian, Roberto Cirio, Mario Ciocca, Flavio Marchetto, V. Monaco, M. Varasteh Anvar, Andrea Attili, M. Donetti, G. V. Russo
Charged particle therapy delivered using scanned pencil beams shows the potential to produce better dose conformity than conventional radiotherapy, although the dose distributions are more sensitive to anatomical changes and patient motion. Therefore
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0d0e7fe62553fe7fe179b9f48b74e633
http://hdl.handle.net/2318/1636713
http://hdl.handle.net/2318/1636713
Autor:
V. Monaco, Giovanni Mazza, L Manganaro, Roberto Cirio, Andrea Attili, Federico Fausti, Flavio Marchetto, Roberto Sacchi, M Lavagno, A. Vignati, Simona Giordanengo, M Fadavi Mazinani
A new wide-input range 64-channels current-to-frequency converter ASIC has been developed and characterized for applications in beam monitoring of therapeutic particle beams. This chip, named TERA09, has been designed to extend the input current rang
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8d9c4813c2d36ec1e58603b5b23930f1
http://hdl.handle.net/11583/2671157
http://hdl.handle.net/11583/2671157
Publikováno v:
Journal of Applied Clinical Medical Physics
When using an electronic portal imaging device (EPID) for dosimetric verifications, the calibration of the sensitive area is of paramount importance. Two calibration methods are generally adopted: one, empirical, based on an external reference dosime
Autor:
Silvia Molinelli, Mario Ciocca, Federico Fausti, V. Monaco, Roberto Cirio, A Vignati, Roberto Sacchi, L Fanola Guarachi, M. Varasteh Anvar, Andrea Attili, M. Donetti, Simona Giordanengo, Flavio Marchetto
Purpose The quality assurance (QA) procedures in particle therapy centers with active beam scanning make extensive use of films, which do not provide immediate results. The purpose of this work is to verify whether the 2D MatriXX detector by IBA Dosi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0c322f64c6ac1dddceda401f91196382
http://hdl.handle.net/11583/2653613
http://hdl.handle.net/11583/2653613