Zobrazeno 1 - 10
of 24
pro vyhledávání: '"Filippo Piatti"'
Autor:
Filippo Piatti, Francesco Sturla, Malenka M. Bissell, Selene Pirola, Massimo Lombardi, Igor Nesteruk, Alessandro Della Corte, Alberto C. L. Redaelli, Emiliano Votta
Publikováno v:
Frontiers in Physiology, Vol 8 (2017)
Bicuspid aortic valve (BAV) is the most common congenital cardiac disease and is a foremost risk factor for aortopathies. Despite the genetic basis of BAV and of the associated aortopathies, BAV-related alterations in aortic fluid-dynamics, and parti
Externí odkaz:
https://doaj.org/article/a411747b137a473594219a89bfc34b57
Autor:
Roberta Visone, Yoojin Shin, Filippo Piatti, Marco Rasponi, Minerva Marcano, Roger D. Kamm, Alberto Redaelli, Kristina Haase
Hemodynamics play a central role in the health and disease of the coronary and peripheral vascular systems. Vessel-lining endothelial cells are known mechanosensors, responding to disturbances in flow – with mechanosensitivity hypothesized to chang
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5ecdc0aeeca650f78bc493a9cd19f0ce
http://hdl.handle.net/11311/1198104
http://hdl.handle.net/11311/1198104
Autor:
Christopher Lau, Mario Gaudino, Emiliano Votta, Leonard N. Girardi, Antonino Di Franco, Carlo Catalano, Alberto Redaelli, Ruggero De Paulis, Nicola Galea, Francesco Sturla, Luca Weltert, Marco Francone, Ilaria Chirichilli, Filippo Piatti, Jonathan W. Weinsaft
Publikováno v:
The Journal of Thoracic and Cardiovascular Surgery. 157:455-465
This study applied advanced 4-dimensional flow magnetic resonance imaging processing to assess differences in aortic flow dynamics after valve sparing root replacement, with and without reconstruction of the Valsalva sinuses.We enrolled patients afte
Autor:
Hector I. Michelena, Angelo Citarella, Marilena Cipollaro, Rasul Ashurov, Emiliano Votta, Federica Lo Presti, Filippo Piatti, Amalia Forte, Alessandro Della Corte
The current management of aortic dilatation associated with congenital bicuspid aortic valve (bicuspid aortic valve aortopathy) is based on dimensional parameters (diameter of the aneurysm, growth of the diameter over time) and few other criteria. Th
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e1b5b5356a3635734f8dcdf6b56ff626
http://hdl.handle.net/11311/1121233
http://hdl.handle.net/11311/1121233
Autor:
Matteo Bianchi, Danny Bluestein, Monica Emendi, Massimo Lombardi, Francesco Sturla, Daniel Giese, Ram P. Ghosh, Filippo Piatti, Francesca R Pluchinotta, Alberto Redaelli
Publikováno v:
Ann Biomed Eng
Congenital bicuspid aortic valve (BAV) consists of two fused cusps and represents a major risk factor for calcific valvular stenosis. Herein, a fully coupled fluid-structure interaction (FSI) BAV model was developed from patient-specific magnetic res
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::488601b404b384404e66ae9605aa2087
http://hdl.handle.net/11311/1154761
http://hdl.handle.net/11311/1154761
Autor:
Emiliano Votta, Francesco Sturla, Alberto Redaelli, Riccardo Vismara, Sergii V. Siryk, Maria Chiara Palumbo, Filippo Consolo, Massimo Lombardi, Filippo Piatti, Andreas Greiser, Gianfranco Beniamino Fiore, Francesca Romana Pluchinotta
Publikováno v:
Journal of Biomechanics. 68:14-23
The performance of blood-processing devices largely depends on the associated fluid dynamics, which hence represents a key aspect in their design and optimization. To this aim, two approaches are currently adopted: computational fluid-dynamics, which
Autor:
Federico Lucherini, Sergii V. Siryk, Alberto Redaelli, Lorenzo Menicanti, Francesco Sturla, Riccardo Vismara, Giordano Tasca, Massimo Lombardi, Daniel Giese, Michal Jaworek, Filippo Piatti, Francesca R Pluchinotta
Publikováno v:
Magnetic resonance imaging. 68
We exploited 4-dimensional flow magnetic resonance imaging (4D Flow), combined with a standardized in vitro setting, to establish a comprehensive benchmark for the systematic hemodynamic comparison of surgical aortic bioprosthetic valves (BPVs).4D Fl
Autor:
Michal Jaworek, Alberto Redaelli, F Pluchinotta, Giordano Tasca, Sergii V. Siryk, D Tresova, Massimo Lombardi, F Lucherini, Francesco Sturla, Christian Geppert, R Vismara, Filippo Piatti
Publikováno v:
European Heart Journal - Cardiovascular Imaging. 20
Autor:
Andrea Foli, Giampaolo Merlini, Giuseppina Palladini, Stefano Perlini, Christian Geppert, Massimo Lombardi, Paolo Milani, Filippo Piatti, Kelvin Chow, Marco Basset, Roberta Mussinelli, Silvia Pica, Antonia Camporeale, Daniel Giese
Publikováno v:
European Heart Journal - Cardiovascular Imaging. 20
Autor:
Federica Cuomo, Francesca Romana Pluchinotta, Massimo Lombardi, Carlos Alberto Figueroa, Filippo Piatti, Federico Lucherini, Selene Pirola, Alberto Redaelli, Mario Carminati, Xiao Yun Xu, Simone Saitta, Christian Geppert, Emiliano Votta
Severity of aortic coarctation (CoA) is currently assessed by estimating trans-coarctation pressure drops through cardiac catheterization or echocardiography. In principle, more detailed information could be obtained non-invasively based on space- an
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8bccb7e9bbb7283b73eeb46ca7da527d
http://hdl.handle.net/11311/1120492
http://hdl.handle.net/11311/1120492