Zobrazeno 1 - 10
of 15
pro vyhledávání: '"Fieke M.E. Cox"'
Publikováno v:
Journal of Clinical Neurophysiology. 38:198-201
PURPOSE The spike-wave index (SWI) is a key feature in the diagnosis of electrical status epilepticus during slow-wave sleep. Estimating the SWI manually is time-consuming and is subject to interrater and intrarater variability. Use of automated dete
Publikováno v:
Seizure. 80
Purpose Complete visual review of prolonged video-EEG recordings at an EMU (Epilepsy Monitoring Unit) is time consuming and can cause problems in times of paucity of educated personnel. In this study we aimed to show non inferiority for electroclinic
Autor:
Nicole Rommens, Fieke M.E. Cox, Gerhard H. Visser, Lisanne Jansen Holleboom, Evelien E. Geertsema
Publikováno v:
Epilepsy & Behavior. 84:99-104
Objective User safety and the quality of diagnostics on the epilepsy monitoring unit (EMU) depend on reaction to seizures. Online seizure detection might improve this. While good sensitivity and specificity is reported, the added value above staff re
Publikováno v:
Epilepsy Research. 129:91-94
Background Long-term video-EEG monitoring (LTM) aims to record the habitual event and is a useful diagnostic tool for neurological paroxysmal clinical events. In our epilepsy monitoring unit (EMU) setting, admissions are usually planned to last up to
Publikováno v:
Epilepsybehavior : EB. 102
Objective No international guideline is available for minimum safety measures at epilepsy monitoring units (EMUs), although recommendations for preferred practices exist. These are mostly based on expert opinion, without evidence of effectiveness. We
Autor:
W. Van Emde Boas, Akio Ikeda, Jong W. Lee, Yoshikazu Ugawa, Ronald P. Lesser, David B. MacDonald, Jana Zárubová, Gerhard H. Visser, Miri Y. Neufeld, H. Aurlien, Kiyohito Terada, Ronit M. Pressler, Hermann Stefan, Friedhelm C. Schmitt, Ingmar Rosén, Tom Eichele, Daniella Terney, Petr Marusic, Beate Diehl, Guido Rubboli, Elena Gardella, Dong Zhou, R. Wennberg, Donald L. Schomer, Pirgit Meritam, Anders Fuglsang-Frederiksen, Lawrence J. Hirsch, Peter W. Kaplan, Sándor Beniczky, Eugen Trinka, Susan T. Herman, Martin Fabricius, Ruta Mameniskiene, Eishi Asano, Fieke M.E. Cox, Monika Eisermann, Jan Brogger, António Martins-da-Silva
Publikováno v:
Schmitt, F C, Aurlien, H, Brøgger, J C, Hirsch, L J, Schomer, D L, Trinka, E, Pressler, R M, Wennberg, R, Visser, G H, Eisermann, M, Diehl, B, Lesser, R P, Kaplan, P W, Nguyen The Tich, S, Lee, J W, Martins-da-Silva, A, Stefan, H, Neufeld, M, Rubboli, G, Fabricius, M E, Gardella, E, Terney, D, Meritam, P, Eichele, T, Asano, E, Cox, F, van Emde Boas, W, Mameniskiene, R, Marusic, P, Zárubová, J, Rosen, I, Fuglsang-Frederiksen, A, Ikeda, A, MacDonald, D B, Terada, K, Ugawa, Y, Zhou, D, Herman, S T & Beniczky, S 2018, ' Standardisierter Computer-basiert-organisierter Report des EEG (SCORE) – Eine strukturierende Form der EEG-Befundung ', Klinische Neurophysiologie, bind 49, nr. 02, s. e1-e18 . https://doi.org/10.1055/s-0043-125304
ZusammenfassungEine 2013 von der „International Federation of Clinical Neurophysiology“ gegründete Taskforce hat eine international konsensfähige EEG-Terminologie entwickelt. Im Folgenden soll das Resultat – die 2. Version des Standardized Co
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::fd9d9bb0f3b56f317ebe729e5db84aaf
https://pure.au.dk/portal/da/publications/standardisierter-computerbasiertorganisierter-report-des-eeg-score--eine-strukturierende-form-der-eegbefundung(f52c5c69-d7bc-4adb-820d-3b8810299520).html
https://pure.au.dk/portal/da/publications/standardisierter-computerbasiertorganisierter-report-des-eeg-score--eine-strukturierende-form-der-eegbefundung(f52c5c69-d7bc-4adb-820d-3b8810299520).html
Autor:
Daniella Terney, Kiyohito Terada, Ingmar Rosén, Beate Diehl, Sándor Beniczky, Fieke M.E. Cox, Richard Wennberg, Jan Brogger, Ronit M. Pressler, Anders Fuglsang-Frederiksen, Hermann Stefan, Lawrence J. Hirsch, Petr Marusic, Gerhard H. Visser, Ronald P. Lesser, Eishi Asano, Eugen Trinka, Tom Eichele, Susan T. Herman, António Martins-da-Silva, Guido Rubboli, Akio Ikeda, Peter W. Kaplan, Elena Gardella, Jong Woo Lee, David B. MacDonald, Jana Zárubová, Pirgit Meritam, Miri Y. Neufeld, Ruta Mameniskiene, Martin Fabricius, H. Aurlien, Donald L. Schomer, Walter van Emde Boas, Friedhelm C. Schmitt, Dong Zhou, Yoshikazu Ugawa, Monika Eisermann
Publikováno v:
Beniczky, S, Aurlien, H, Brøgger, J C, Hirsch, L J, Schomer, D L, Trinka, E, Pressler, R M, Wennberg, R, Visser, G H, Eisermann, M, Diehl, B, Lesser, R P, Kaplan, P W, Nguyen The Tich, S, Lee, J W, Martins-da-Silva, A, Stefan, H, Neufeld, M, Rubboli, G, Fabricius, M, Gardella, E, Terney, D, Meritam, P, Eichele, T, Asano, E, Cox, F, van Emde Boas, W, Mameniskiene, R, Marusic, P, Zárubová, J, Schmitt, F C, Rosén, I, Fuglsang-Frederiksen, A, Ikeda, A, MacDonald, D B, Terada, K, Ugawa, Y, Zhou, D & Herman, S T 2017, ' Standardized computer-based organized reporting of EEG : SCORE – Second version ', Clinical Neurophysiology, vol. 128, no. 11, pp. 2334-2346 . https://doi.org/10.1016/j.clinph.2017.07.418
Beniczky, S, Aurlien, H, Brøgger, J C, Hirsch, L J, Schomer, D L, Trinka, E, Pressler, R M, Wennberg, R, Visser, G H, Eisermann, M, Diehl, B, Lesser, R P, Kaplan, P W, Nguyen The Tich, S, Lee, J W, Martins-da-Silva, A, Stefan, H, Neufeld, M, Rubboli, G, Fabricius, M, Gardella, E, Terney, D, Meritam, P, Eichele, T, Asano, E, Cox, F, van Emde Boas, W, Mameniskiene, R, Marusic, P, Zárubová, J, Schmitt, F C, Rosén, I, Fuglsang-Frederiksen, A, Ikeda, A, MacDonald, D B, Terada, K, Ugawa, Y, Zhou, D & Herman, S T 2017, ' Standardized computer-based organized reporting of EEG : SCORE-Second version ', Clinical Neurophysiology, vol. 128, no. 11, pp. 2334-2346 . https://doi.org/10.1016/j.clinph.2017.07.418
Beniczky, S, Aurlien, H, Brøgger, J C, Hirsch, L J, Schomer, D L, Trinka, E, Pressler, R M, Wennberg, R, Visser, G H, Eisermann, M, Diehl, B, Lesser, R P, Kaplan, P W, Nguyen The Tich, S, Lee, J W, Martins-da-Silva, A, Stefan, H, Neufeld, M, Rubboli, G, Fabricius, M, Gardella, E, Terney, D, Meritam, P, Eichele, T, Asano, E, Cox, F, van Emde Boas, W, Mameniskiene, R, Marusic, P, Zárubová, J, Schmitt, F C, Rosén, I, Fuglsang-Frederiksen, A, Ikeda, A, MacDonald, D B, Terada, K, Ugawa, Y, Zhou, D & Herman, S T 2017, ' Standardized computer-based organized reporting of EEG SCORE-Second version ', Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology, vol. 128, no. 11, pp. 2334-2346 . https://doi.org/10.1016/j.clinph.2017.07.418
Beniczky, S, Aurlien, H, Brøgger, J C, Hirsch, L J, Schomer, D L, Trinka, E, Pressler, R M, Wennberg, R, Visser, G H, Eisermann, M, Diehl, B, Lesser, R P, Kaplan, P W, Nguyen The Tich, S, Lee, J W, Martins-da-Silva, A, Stefan, H, Neufeld, M, Rubboli, G, Fabricius, M, Gardella, E, Terney, D, Meritam, P, Eichele, T, Asano, E, Cox, F, van Emde Boas, W, Mameniskiene, R, Marusic, P, Zárubová, J, Schmitt, F C, Rosén, I, Fuglsang-Frederiksen, A, Ikeda, A, MacDonald, D B, Terada, K, Ugawa, Y, Zhou, D & Herman, S T 2017, ' Standardized computer-based organized reporting of EEG : SCORE-Second version ', Clinical Neurophysiology, vol. 128, no. 11, pp. 2334-2346 . https://doi.org/10.1016/j.clinph.2017.07.418
Beniczky, S, Aurlien, H, Brøgger, J C, Hirsch, L J, Schomer, D L, Trinka, E, Pressler, R M, Wennberg, R, Visser, G H, Eisermann, M, Diehl, B, Lesser, R P, Kaplan, P W, Nguyen The Tich, S, Lee, J W, Martins-da-Silva, A, Stefan, H, Neufeld, M, Rubboli, G, Fabricius, M, Gardella, E, Terney, D, Meritam, P, Eichele, T, Asano, E, Cox, F, van Emde Boas, W, Mameniskiene, R, Marusic, P, Zárubová, J, Schmitt, F C, Rosén, I, Fuglsang-Frederiksen, A, Ikeda, A, MacDonald, D B, Terada, K, Ugawa, Y, Zhou, D & Herman, S T 2017, ' Standardized computer-based organized reporting of EEG SCORE-Second version ', Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology, vol. 128, no. 11, pp. 2334-2346 . https://doi.org/10.1016/j.clinph.2017.07.418
Standardized terminology for computer-based assessment and reporting of EEG has been previously developed in Europe. The International Federation of Clinical Neurophysiology established a taskforce in 2013 to develop this further, and to reach intern
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d8cad58ccbe8b846d3c38ff3f4de5739
https://findresearcher.sdu.dk:8443/ws/files/135387487/Standardized_computer_based_organized_reporting_of_EEG.pdf
https://findresearcher.sdu.dk:8443/ws/files/135387487/Standardized_computer_based_organized_reporting_of_EEG.pdf
Publikováno v:
Epilepsia, 57(11), 1748-1753
SummaryObjective Following a sudden death at a residential care unit, the Dutch Health and Care Inspectorate advised intensification of the use of video monitoring (VM) at the unit. We assessed whether VM resulted in increased identification of seizu
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::969e8da3bf0a80b1d4b108185b5c5acc
https://hdl.handle.net/1887/112649
https://hdl.handle.net/1887/112649
Publikováno v:
Cox, F M E, van Beijeren, E & Velis, D N 2016, ' Eye closure sensitivity and catamenial nonconvulsive status epilepticus-A case report ', Clinical Neurophysiology, vol. 127, no. 3, pp. 1918-1920 . https://doi.org/10.1016/j.clinph.2015.11.040
Clinical Neurophysiology, 127(3), 1918-1920. Elsevier Ireland Ltd
Clinical Neurophysiology, 127(3), 1918-1920. Elsevier Ireland Ltd
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d55a1e195530d7872fcd05646014a621
https://research.vumc.nl/en/publications/a65acf34-41b7-41e0-bf21-78e40515dd16
https://research.vumc.nl/en/publications/a65acf34-41b7-41e0-bf21-78e40515dd16
Autor:
Jan J.G.M. Verschuuren, Fieke M.E. Cox, Carla S P van Rijswijk, Monique Reijnierse, Umesh A. Badrising, Axel R. Wintzen
Publikováno v:
Rheumatology, 50(6), 1153-1161
Objective. To analyse whether MRI of upper and lower extremity muscles in a large patient group with sporadic IBM (sIBM) is of additional value in the diagnostic work-up of sIBM. Methods. Thirty-two sIBM patients were included. Magnetic resonance (MR