Zobrazeno 1 - 6
of 6
pro vyhledávání: '"Felix Brauchle"'
Publikováno v:
ChemElectroChem, Vol 10, Iss 17, Pp n/a-n/a (2023)
Abstract Reference electrodes (REs) play a crucial role in the accurate assessment and control of battery potentials, but their confidence is overestimated. Researchers have tracked the source of the error to the RE design that blocks the lithium‐i
Externí odkaz:
https://doaj.org/article/0e5be92994414548b095099a8822ce6e
Autor:
Felix Brauchle, Daniel Rapp, Makbule Senel, André Huss, Jens Dreyhaupt, Veronika Klose, Marie Süße, Klarissa Hanja Stürner, Frank Leypoldt, Hayrettin Tumani, Jan Lewerenz
Publikováno v:
Frontiers in Neurology, Vol 14 (2023)
IntroductionThe polyspecific intrathecal immune response (PSIIR), aka MRZ reaction (M = measles, R = rubella, Z = zoster, optionally Herpes simplex virus, HSV) is defined as intrathecal immunoglobulin synthesis (IIS) for two or more unrelated viruses
Externí odkaz:
https://doaj.org/article/93c30f719cff48418790e13cea2f0159
Lithium-ion cells exhibit a dilation during charge and discharge cycles and over their lifetime. Quantifying this dilation is a reliable method to characterize materials and observe degradation mechanisms. Currently, such experiments base on dial gau
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::277c8dd88c679a1e23ef98de35e4ecc3
https://doi.org/10.36227/techrxiv.22815452
https://doi.org/10.36227/techrxiv.22815452
Publikováno v:
Journal of Power Sources. 558:232587
Autor:
Kai Peter Birke, Severin Hahn, Tobias Deich, Thomas Soczka-Guth, Dragoljub Vrankovic, Otto von Kessel, Felix Brauchle
Publikováno v:
Journal of Power Sources. 508:230337
Mechanical stress in constrained lithium-ion cells impacts both performance and battery lifetime. Among cell swelling during charging and due to aging, the mechanical properties of the cell stack itself influences stress development. However, the com
Publikováno v:
Journal of Power Sources. 507:230292
Inhomogeneous current distribution in lithium-ion cells is a major reason for degradation. A method to measure the locally resolved current distribution is to map the magnetic field caused by the current flowing in the cell. This paper presents an un