Zobrazeno 1 - 10
of 13
pro vyhledávání: '"Federico Nicolás Guerrero"'
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 69:1682-1689
A high input impedance circuit to convert a single-ended (SE) voltage to its differential counterpart is proposed. It allows setting the common-mode (CM) output voltage to a reference voltage vR, while providing gain and a balanced output. The circui
Publikováno v:
IEEE Transactions on Biomedical Circuits and Systems. 12:437-445
This paper presents a novel two-wired active electrode that achieves ultrahigh input impedance using power supply bootstrapping. The proposed circuit reduces the input capacitance of a buffer amplifier while enabling measurements using leads with onl
Sigma Delta analogue-to-digital converters allow acquiring the full dynamic range of biomedical signals at the electrodes, resulting in less complex hardware and increased measurement robustness. However, the increased data size per sample (typically
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::9d3c698803367e081f5cfce4945a6539
https://www.tandfonline.com/doi/full/10.1080/03091902.2017.1366562
https://www.tandfonline.com/doi/full/10.1080/03091902.2017.1366562
Autor:
Federico Nicolás Guerrero
Publikováno v:
SEDICI (UNLP)
Universidad Nacional de La Plata
instacron:UNLP
Universidad Nacional de La Plata
instacron:UNLP
La tesis pretende contribuir al conocimiento en adquisición de biopotenciales mediante técnicas no invasivas con aplicación a neuroprótesis (NPs). Las NPs son dispositivos que, interactuando con el cuerpo humano, permiten recuperar o reemplazar c
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b6eb10f7d43453f53073ccb0f4ad3647
http://sedici.unlp.edu.ar/handle/10915/59568
http://sedici.unlp.edu.ar/handle/10915/59568
Publikováno v:
VII Latin American Congress on Biomedical Engineering CLAIB 2016, Bucaramanga, Santander, Colombia, October 26th-28th, 2016 ISBN: 9789811040856
In this work, the signal modes necessary for the analysis of amplifiers for double differential and normal double differential electrodes are obtained for the first time. Superficial electromyographic (sEMG) electrodes may have multiple dry contacts
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::7cc22b135eae748fa2c6a896f6a24460
https://doi.org/10.1007/978-981-10-4086-3_127
https://doi.org/10.1007/978-981-10-4086-3_127
Publikováno v:
Medical engineeringphysics. 39
This paper presents an improved driven right leg (DRL) circuit compensation together with a practical implementation. The proposed design allows to increase common mode voltage attenuation compared with the widely used dominant pole compensation whil
Publikováno v:
IEEE transactions on biomedical circuits and systems. 10(3)
In this paper we present an analysis of the voltage amplifier needed for double differential (DD) sEMG measurements and a novel, very simple circuit for implementing DD active electrodes. The three-input amplifier that standalone DD active electrodes
Publikováno v:
SEDICI (UNLP)
Universidad Nacional de La Plata
instacron:UNLP
Universidad Nacional de La Plata
instacron:UNLP
Capacitive Electrodes (CE) allow the acquisition of biopotentials through a dielectric layer, without the use of electrolytes, just by placing them on skin or clothing, but demands front-ends with ultra-high input impedances. This must be achieved wh
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::212b8a62cf1a20c7202b768ad1ea0706
https://www.sciencedirect.com/science/article/abs/pii/S1350453315002854
https://www.sciencedirect.com/science/article/abs/pii/S1350453315002854
Publikováno v:
IFMBE Proceedings ISBN: 9783319131160
This work presents a neuro-muscular stimulator (NMS) specially designed for autonomous neuroprosthesis, and focused on the optimization of the battery energy consumption. The main feature of the proposed NMS is that it does not use an auxiliary high
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::13c33b2a7d721e7d820a35e65510bd60
https://doi.org/10.1007/978-3-319-13117-7_4
https://doi.org/10.1007/978-3-319-13117-7_4
Publikováno v:
SEDICI (UNLP)
Universidad Nacional de La Plata
instacron:UNLP
IFMBE Proceedings ISBN: 9783319131160
Universidad Nacional de La Plata
instacron:UNLP
IFMBE Proceedings ISBN: 9783319131160
A surface electromiography (sEMG) multichannel aquisition system was implemented using dry electrodes. Branched electrodes were used to obtain spatially selective EMG measurements. Active electrodes coupled with a high dynamic range converter were us
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::43a9fcf84f77b2378869a841c9bf41a4
http://sedici.unlp.edu.ar/handle/10915/146214