IET Electric Power Applications, Vol 18, Iss 5, Pp 543-555 (2024)
Abstract A new technique is proposed for loss of field (LOF) detection in synchronous generators (SGs). The proposed scheme employs the variations of SG angular velocity ∆ωφ and load angle ∆δφ to reach this goal, while the mentioned parameter
Externí odkaz:
https://doaj.org/article/2993a199aa0a4f90bf79e8e0751f2ff9
Publikováno v:
IET Generation, Transmission & Distribution, Vol 17, Iss 4, Pp 875-895 (2023)
Abstract The issue of resilience in electrical distribution systems has been proposed increasingly with the frequent occurrence of natural disasters in recent years and the imposition of high costs due to widespread power outages. To date, various re
Externí odkaz:
https://doaj.org/article/41cdde0b0c444662b557fcb060a7b643
Publikováno v:
IET Electric Power Applications, Vol 15, Iss 9, Pp 1138-1153 (2021)
Abstract Here a new sensitive fault detection criterion is proposed, based on the stationary wavelet transform (SWT) decomposition components of the stator currents, for the online detection of stator winding turn‐to‐turn faults at an early stage
Externí odkaz:
https://doaj.org/article/81a920084dac4672bceedeca869e3f76
Publikováno v:
IET Generation, Transmission & Distribution. 17:875-895
Publikováno v:
International Journal of Circuit Theory and Applications. 50:2687-2708
Publikováno v:
Research and Technology in the Electrical Industry. 1:105-113
Publikováno v:
Electric Power Systems Research. 222:109498
Publikováno v:
IEEE Transactions on Industrial Electronics. 68:7485-7495
An invasive diagnostic technique is proposed in this article for the detection and discrimination of turn-to-turn faults in the stator and rotor windings of synchronous machines during the startup period. For this purpose, search coils are installed
Publikováno v:
IET Electric Power Applications, Vol 15, Iss 9, Pp 1138-1153 (2021)
Here a new sensitive fault detection criterion is proposed, based on the stationary wavelet transform (SWT) decomposition components of the stator currents, for the online detection of stator winding turn‐to‐turn faults at an early stage of devel
Publikováno v:
IEEE Transactions on Energy Conversion. 36:264-271
A portable flux probe is proposed and investigated in this article to detect turn-to-turn fault in the rotor poles of the high rated salient pole synchronous machines. The rotor circuit is fed by a low amplitude sinusoidal voltage source with a fixed