Zobrazeno 1 - 10
of 18
pro vyhledávání: '"Fan-Chun Hsieh"'
Publikováno v:
Materials, Vol 15, Iss 12, p 4159 (2022)
The use of poly-(para-chloro-xylylene) (Parylene C) in microelectromechanical systems and medical devices has increased rapidly. However, little research has been conducted on the wettability and surface roughness of Parylene C after being soaked in
Externí odkaz:
https://doaj.org/article/64cb3f7a983f4b899106b8f067188e7f
Publikováno v:
Sensors, Vol 14, Iss 11, Pp 22099-22112 (2014)
In this study, we develop a clamped–clamped beam-type piezoelectric vacuum pressure sensing element. The clamped–clamped piezoelectric beam is composed of a PZT layer and a copper substrate. A pair of electrodes is set near each end. An input vol
Externí odkaz:
https://doaj.org/article/097eee9b34f74a3e903e2135d8d54413
Autor:
Fan-Chun Hsieh, 謝汎鈞
99
The purpose of this project is developed an impact of system. According to this system, it can be used to measure five items which are (1) velocity of block before collision, (2) position of block, (3) during the velocity of block, (4) image
The purpose of this project is developed an impact of system. According to this system, it can be used to measure five items which are (1) velocity of block before collision, (2) position of block, (3) during the velocity of block, (4) image
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/52241559813839149293
Autor:
Fan-Chun Hsieh, 謝汎鈞
96
An experiment combining flow visualization and temperature measurement is carried out here to explore the effects of disk rotation on the vortex flows resulting from a round jet of air impinging onto a heated horizontal disk confined in a ver
An experiment combining flow visualization and temperature measurement is carried out here to explore the effects of disk rotation on the vortex flows resulting from a round jet of air impinging onto a heated horizontal disk confined in a ver
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/63867746095352477942
Autor:
Fan-Chun Hsieh, 謝汎鈞
90
The project presents a numerical for predicting the anode shapes in the electrochemical machining with prescribed tool shape. The conductivity of, and the variation of electrolyte conductivity with temperature had been taken into account in n
The project presents a numerical for predicting the anode shapes in the electrochemical machining with prescribed tool shape. The conductivity of, and the variation of electrolyte conductivity with temperature had been taken into account in n
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/86845719350464965813
Vortex flow affected by disk rotation in an air jet impinging onto a confined heated horizontal disk
Autor:
Fan-Chun Hsieh, Tsing-Fa Lin
Publikováno v:
International Journal of Thermal Sciences. 184:107905
Publikováno v:
Surface and Coatings Technology. 260:272-278
This study employed a temperature controlled capacitance-based system to measure the mechanical behaviors associated with temperature dependent energy loss in ultra-thin copper (Cu) films. Thin Cu films are widely used in electronic interconnections
Publikováno v:
Sensors
Volume 14
Issue 11
Pages 22099-22112
Sensors, Vol 14, Iss 11, Pp 22099-22112 (2014)
Sensors (Basel, Switzerland)
Volume 14
Issue 11
Pages 22099-22112
Sensors, Vol 14, Iss 11, Pp 22099-22112 (2014)
Sensors (Basel, Switzerland)
In this study, we develop a clamped-clamped beam-type piezoelectric vacuum pressure sensing element. The clamped-clamped piezoelectric beam is composed of a PZT layer and a copper substrate. A pair of electrodes is set near each end. An input voltage
Publikováno v:
I2MTC
The use of additive manufacturing (AM) is expanding rapidly; however, the mechanical behavior of printing materials has yet to be fully elucidated. In this study, we examined UV-cured photopolymers designed for use in PolyJet systems. We tested the s
Autor:
Chih-Yu Chen, Shu-Wei Huang, Jui-Sheng Sun, Shin-Yiing Lin, Chih-Sheng Yu, Hsu-Pin Pan, Ping-Hung Lin, Fan-Chun Hsieh, Yang-Hwei Tsuang, Feng-Huei Lin, Rong-Sen Yang, Cheng-Kung Cheng
Publikováno v:
Medical engineeringphysics. 44
The dynamic hip screw (DHS) is commonly used in the treatment of femoral intertrochanteric fracture with high satisfactory results. However, post-operative failure does occur and result in poor prognosis. The most common failure is femoral head varus