Thermeau, Jean-Pierre, Gajewski, Konrad, Hermansson, Lars, Junquera, Tomas, Kochebina, Olga, Ruber, Roger, Santiago Kern, Rocio
Publikováno v:
19th International Conference on RF Superconductivity (SRF 2019)
19th International Conference on RF Superconductivity (SRF 2019), Jun 2019, Dresden, Germany. pp.THP034, ⟨10.18429/JACoW-SRF2019-THP034⟩
19th International Conference on RF Superconductivity (SRF 2019), Jun 2019, Dresden, Germany. pp.THP034, ⟨10.18429/JACoW-SRF2019-THP034⟩
A new vertical cryostat, called Gersemi, installed at FREIA Laboratory at Uppsala University, Sweden, is designed to test superconducting magnets and radio-frequency cavities and operates at temperatures between 1.8 K and 4.2 K. Two different inserts
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8f9964b2571c97526fadb72117a7f3be
https://hal.archives-ouvertes.fr/hal-02497837
https://hal.archives-ouvertes.fr/hal-02497837
Autor:
Turaj, Katarzyna, Arnaudon, Luca, Baudrenghien, Philippe, Brunner, Olivier, Butterworth, Andrew, Gerigk, Frank, Karppinen, Mikko, Maesen, Pierre, Montesinos, Eric, Peauger, Franck, Rosaz, Guillaume, Shaposhnikova, Elena, Smekens, David, Taborelli, Mauro, Therasse, Mathieu, Timko, Helga, Valuch, Daniel, Valverde Alonso, Nuria, Venturini Delsolaro, Walter
The LHC accelerating RF system consists of two cryomodules per beam, each containing four single-cell niobium sputtered 400.8 MHz superconducting cavities working at 4.5 K and an average accelerating voltage of 2 MV. The paper summarises the experien
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7b8f7b3495cb3d90f956207a0a69e148
http://cds.cern.ch/record/2712616
http://cds.cern.ch/record/2712616
Autor:
Wei, Jie, Ao, Hiroyuki, Beher, Steven, Bird, Brian, Bultman, Nathan, Casagrande, Fabio, Chabot, Daron, Chang, Wei, Cogan, Scott, Compton, Chris, Curtin, John, Davidson, Kelly, Daykin, Evan, Dixon, Kelly, Elliott, Kyle, Facco, Alberto, Fila, Adam, Ganni, Venkatarao, Ganshyn, Andrei, Gibson, Paul, Glasmacher, Thomas, Grender, Ian, Hartung, Walter, Hodges, Leslie, Holland, Kent, Hosoyama, Kenji, Hseuh, Hsiao-Chaun, Hussain, Aftab, Ikegami, Masanori, Jones, Shelly, Kanemura, Takuji, Kelly, Michael, Kim, Sang-Hoon, Knudsen, Peter, Konrad, Martin, Laxdal, Robert, LeTourneau, John, Li, ZhiYong, Lidia, Steven, Machicoane, Guillaume, Manwiller, Peter, Marti, Felix, Maruta, Tomofumi, Metzgar, Ethan, Miller, Samuel, Morris, Dan, Nguyen, Chinh, Openlander, Keith, Ostroumov, Peter, Plastun, Alexander, Popielarski, John, Popielarski, Laura, Priller, John, Reaume, Marc, Ren, Haitao, Russo, Thomas, Saito, Kenji, Shuptar, Mark, Stetson, Jeffry, Victory, Daniel, Walker, Roben, Wang, Xiaole, Wenstrom, John, Wiseman, Mark, Wright, Mathew, Xu, Mengxin, Xu, Ting, Yamazaki, Yoshishige, Zhao, Qiang, Zhao, Shen
The Facility for Rare Isotope Beams (FRIB) superconducting (SC) driver linac is designed to accelerate all stable ions including uranium to energies above 200 MeV/u primarily with 46 cryomodules containing 324 quarter-wave resonators (QWR) and half-w
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::af95b72b6189bbc17fde227f5853ccb3
Autor:
Christou, Chris, Gu, Pengda, Marten, Peter, Pande, Shivaji, Rankin, Adam, Spink, David, Stant, Laurence, Tropp, Anton
Diamond Light Source has been providing beam for users since January 2007. The electron beam in the storage ring is normally driven by two superconducting CESR-B cavities, with two similar cavities available as spares. Day-to-day reliability of the c
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::b4904402528e9953ca9de140dd291599
Publikováno v:
The 19th International Conference on RF Superconductivity (SRF2019), 23.-30.06.2019, Dresden, GermanyProceedings of SRF 2019, JACoW: JACoW, 978-3-95450-211-0, 907-912
Accelerator-based light sources, in particular, those based on linear accelerators, are intrinsically less stable than lasers or other more conventional light sources because of their large scale. In order to achieve optimal data quality, the propert
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7bfcf0fce04978560fa3b8940ef9c308
Autor:
Heling, Svenja, Anders, Wolfgang, Heinrich, Jochen, Hellwig, Axel, Janke, Karsten, Rotterdam, Stefan
In Berlin-Adlershof the Helmholtz-Zentrum Berlin (HZB) is operating the synchrotron radiation source BESSY II. Two superconducting wave-length shifter magnets are built-in the storage ring of BESSY II which are cooled with liquid helium. Additionally
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::2e9f661fa3af47a729aaf65b3fb6cbc3
Autor:
Xiang, Rong, Arnold, Andre, Evtushenko, Pavel, Kovalev, Sergey, Lehnert, Ulf, Lu, Pengnan, Ma, Shuai, Michel, Peter, Murcek, Petr, Ryzhov, Anton, Schaber, Jana, Schneider, Christof, Teichert, Jochen, Vennekate, Hannes, Will, Ingo
Publikováno v:
The 19th International Conference on RF Superconductivity(SRF2019), 30.06.-05.07.2019, Dresden, Germany
The 19th International Conference on RF Superconductivity(SRF2019), 30.06.-05.07.2019, Dresden, GermanyProceedings of the 19th International Conference on RF Superconductivity: JACoW, 978-3-95450-211-0
The 19th International Conference on RF Superconductivity(SRF2019), 30.06.-05.07.2019, Dresden, GermanyProceedings of the 19th International Conference on RF Superconductivity: JACoW, 978-3-95450-211-0
The first all-SRF accelerator driven THz source has been operated as a user facility since 2018 at ELBE radiation center. The CW electron beam is extracted from SRF gun II, accelerated to relativistic energies and compressed to sub-ps length in the E
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d47e726c16ea7717f6347d19d78c5e63
https://www.hzdr.de/publications/Publ-31120-1
https://www.hzdr.de/publications/Publ-31120-1
Autor:
Ross, Marc
The Linac Coherent Light Source II (LCLS-II) project requires the assembly, test, and installation of 37 cryomodules (CM) in order to deliver a 4 GeV CW electron beam to the FEL undulators for production of both hard and soft X-ray pulses at a repeti
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::4d5f0ab2fb638dda5ae4302b17453f6a
Autor:
Yamada, Kazunari, Dantsuka, Tomoyuki, Hara, Hiroshi, Imao, Hiroshi, Kako, Eiji, Kamigaito, Osamu, Kusaka, Kensuke, Miyamoto, Akihiro, Nakai, Hirotaka, Okuno, Hiroki, Ozeki, Kazutaka, Sakai, Hiroshi, Sakamoto, Naruhiko, Sennyu, Katsuya, Suda, Kenji, Umemori, Kensei, Watanabe, Tamaki, Watanabe, Yutaka, Yanagisawa, Takeshi
At RIKEN Nishina Center, the RIKEN Heavy-Ion Linac (RILAC) is undergoing an upgrade of its acceleration voltage in order to allow it further investigation of new super-heavy elements. In this project, a new superconducting (SC) booster linac, so-call
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::1e11678498887a20a3e099e3d02f4b7e
The two superconducting radio frequency acceleration cryomodules for the new multiturn ERL ’Mainz Energy Recovering Superconducting Accelerator’ MESA at Johannes Gutenberg-Universität Mainz have been fabricated and are currently under testing at
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::9d7c6639cefff01570bdf6a2ca10f9f7