Zobrazeno 1 - 10
of 11 123
pro vyhledávání: '"FATIS"'
Autor:
Addesa, F., Anderson, T., Barria, P., Basile, C., Benaglia, A., Bertoni, R., Bethani, A., Bianco, R., Bornheim, A., Boldrini, G., Boletti, A., Bulla, A., Campana, M., Cardwell, B., Carniti, P., Cetorelli, F., De Guio, F., De Leo, K., De Riggi, F., Dervan, J., Fernandez, E., Gaile, A., Gallinaro, M., Ghezzi, A., Gotti, C., Goldouzian, R., Guglielmi, V., Heering, A., Hu, Z., Jose, M., Karneyeu, A., Krishna, A., Kronheim, B., Kuo, C., La Torre, A., Li, A., Lombardi, F., Lucchini, M. T., Malberti, M., Mao, Y., Marzocchi, B., Meridiani, P., Musienko, Y., Neu, C., Organtini, G., Orimoto, T., Palmer, C., Paganoni, M., Palluotto, S., Paramatti, R., Pessina, G., Perelman, R. T., Quaranta, C., Redaelli, N., Redaelli, S., Gutiérrez, G. Reales, Ronchi, S., Santanastasio, F., Schmidt, I., Silva, J. C., Sorrentino, G., Sun, X., de Fatis, T. Tabarelli, Tosi, M., Ujvari, B., Varela, J., Wang, J., Wayne, M., White, S., Zhang, L., Zhang, M.
For the High-Luminosity (HL-LHC) phase, the upgrade of the Compact Muon Solenoid (CMS) experiment at CERN will include a novel MIP Timing Detector (MTD). The central part of MTD, the barrel timing layer (BTL), is designed to provide a measurement of
Externí odkaz:
http://arxiv.org/abs/2410.08738
Autor:
Fatisson, Julien
La thèse décrit la caractérisation physico-chimique et les applications électroanalytiques de nouveaux matériaux nanocomposites, déposés sur des surfaces d'électrode par autoassemblage électrostatique de polyélectrolytes (PE), d'enzymes et
Externí odkaz:
http://tel.archives-ouvertes.fr/tel-00011154
http://tel.archives-ouvertes.fr/docs/00/05/09/16/PDF/Manuscrit_complet_vdef.pdf
http://tel.archives-ouvertes.fr/docs/00/05/09/16/PDF/Manuscrit_complet_vdef.pdf
Autor:
Cigdem Akyol Beyoglu, Serkan Teksoz, Aylin Ozdilek, Murat Akcivan, Emre Erbabacan, Fatis Altindas, Guniz Koksal
Publikováno v:
BMC Surgery, Vol 20, Iss 1, Pp 1-7 (2020)
Abstract Background Various techniques are used to detect intraoperative bleeding points in thyroid surgery. We aimed to assess the effect of increasing peak airway pressure to 30, 40 and 50 cm H2O manually in detecting intraoperative bleeding points
Externí odkaz:
https://doaj.org/article/847dfb91a26a45989e36a7a2da2e55c0
Autor:
Albuquerque, E., Araújo, M., Benaglia, A., Boletti, A., Bugalho, R., Coutinho, T., De Guio, F., Faccioli, P., Ferramacho, L., Firlej, M., Fiutowski, T., Francisco, R., Gallinaro, M., Ghezzi, A., Hollar, J., Idzik, M., Legoinha, H., Leonardo, N., Leong, C., Lucchini, M. T., Malberti, M., Marozzo, G., Da Molin, G., Moron, J., Niknejad, T., Oliveira, L., Oliveira, N., Palluotto, S., Pisano, M., Redaelli, N., Silva, C., Silva, J. C., Silva, R., Silveira, M., Swientek, K., de Fatis, T. Tabarelli, Tavernier, S., Varela, J., Varela, V., White, S., Wulff, J.
The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on
Externí odkaz:
http://arxiv.org/abs/2404.01208
Publikováno v:
Cukurova Medical Journal, Vol 42, Iss 2, Pp 210-215 (2017)
Amaç: Bu çalışmada Maraş otu (dumansız tütün) kullanımının kan basıncı ve kalp hızı üzerine akut etkisinin belirlenmesi amaçlanmıştır.Gereç ve Yöntem: Bu çalışma Kahramanmaraş ilindeki 20 kıraathanede, 140 gönüllü erkek
Externí odkaz:
https://doaj.org/article/9e6402899838479c87d8ee38e8e8ca88
Autor:
Bornheim, A., Lustermann, W., Stachon, K., Gutiérrez, G. Reales, Benaglia, A., De Guio, F., Ghezzi, A., Lucchini, M. T., Malberti, M., Palluotto, S., de Fatis, T. Tabarelli, Benettoni, M., Carlin, R., Tosi, M., Rossin, R., Meridiani, P., Paramatti, R., Santanastasio, F., Silva, J. C., Varela, J., Heering, A., Karneyeu, A., Musienko, Y., Wayne, M., Anderson, T., Cox, B., Lara, C. E. Perez, Ledovskoy, A., White, S., Schmidt, I.
Publikováno v:
JINST 18 P08020 (2023)
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read out with Si
Externí odkaz:
http://arxiv.org/abs/2306.00818
Publikováno v:
Clinics, Vol 66, Iss 4, Pp 709-711 (2011)
Externí odkaz:
https://doaj.org/article/ee9e9c52dd794fb6854b5c6b9744b097
Autor:
Charalampopoulou, Alexandra, Barcellini, Amelia, Bistika, Margarita, Ivaldi, Giovanni Battista, Lillo, Sara, Magro, Giuseppe, Orlandi, Ester, Pullia, Marco Giuseppe, Ronchi, Sara, De Fatis, Paola Tabarelli, Facoetti, Angelica
Publikováno v:
In International Journal of Particle Therapy December 2024 14
Autor:
Abbott, R., Abreu, A., Addesa, F., Alhusseini, M., Anderson, T., Andreev, Y., Apresyan, A., Arcidiacono, R., Arenton, M., Auffray, E., Bastos, D., Bauerdick, L. A. T., Bellan, R., Bellato, M., Benaglia, A., Benettoni, M., Bertoni, R., Besancon, M., Bharthuar, S., Bornheim, A., Brücken, E., Butler, J. N., Campagnari, C., Campana, M., Carlin, R., Carniti, P., Cartiglia, N., Casarsa, M., Cerri, O., Checchia, P., Chen, H., Chidzik, S., Chlebana, F., Cossutti, F., Costa, M., Cox, B., Dafinei, I., De Guio, F., Debbins, P., del Re, D., Dermenev, A., Di Marco, E., Dilsiz, K., Di Petrillo, K. F., Dissertori, G., Dogra, S., Dosselli, U., Dutta, I., Caleb, F., Madrazo, C. Fernandez, Fernandez, M., Ferrero, M., Flowers, Z., Funk, W., Gallinaro, M., Ganjour, S., Gardner, M., Geurts, F., Ghezzi, A., Gninenko, S., Golf, F., Gonzalez, J., Gotti, C., Gray, L., Guilloux, F., Gundacker, S., Hazen, E., Hedia, S., Heering, A., Heller, R., Isidori, T., Isocrate, R., Jaramillo, R., Joyce, M., Kaadze, K., Karneyeu, A., Kim, H., King, J., Kopp, G., Korjik, M., Koseyan, O. K., Kozyrev, A., Kratochwil, N., Lazarovits, M., Ledovskoy, A., Lee, H., Lee, J., Li, A., Li, S., Li, W., Liu, T., Lu, N., Lucchini, M., Lustermann, W., Madrid, C., Malberti, M., Mandjavize, I., Mao, J., Maravin, Y., Marlow, D., Marsh, B., del Arbol, P. Martinez, Marzocchi, B., Mazza, R., McMahon, C., Mechinsky, V., Meridiani, P., Mestvirishvili, A., Minafra, N., Mohammadi, A., Monti, F., Moon, C. S., Mulargia, R., Murray, M., Musienko, Y., Nachtman, J., Nargelas, S., Narvaez, L., Neogi, O., Neu, C., Niknejad, T., Obertino, M., Ogul, H., Oh, G., Ojalvo, I., Onel, Y., Organtini, G., Orimoto, T., Ott, J., Ovtin, I., Paganoni, M., Pandolfi, F., Paramatti, R., Peck, A., Perez, C., Pessina, G., Pena, C., Pigazzini, S., Radchenko, O., Redaelli, N., Rigoni, D., Robutti, E., Rogan, C., Rossin, R., Rovelli, C., Royon, C., Sahin, M. Ö., Sands, W., Santanastasio, F., Sarica, U., Schmidt, I., Schmitz, R., Sheplock, J., Silva, J. C., Siviero, F., Soffi, L., Sola, V., Sorrentino, G., Spiropulu, M., Spitzbart, D., Leiton, A. G. Stahl, Staiano, A., Stuart, D., Suarez, I., de Fatis, T. Tabarelli, Tamulaitis, G., Tang, Y., Tannenwald, B., Taylor, R., Tiras, E., Titov, M., Tkaczyk, S., Tlisov, D., Tlisova, I., Tornago, M., Tosi, M., Tramontano, R., Trevor, J., Tully, C. G., Ujvari, B., Varela, J., Ventura, S., Vila, I., Wamorkar, T., Wang, C., Wang, X., Wayne, M., Wetzel, J., White, S., Winn, D., Wu, S., Xie, S., Ye, Z., Yu, G. B., Zhang, G., Zhang, L., Zhang, Y., Zhang, Z., Zhu, R.
Publikováno v:
Journal of Instrumentation, Volume 16, July 2021
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector
Externí odkaz:
http://arxiv.org/abs/2104.07786
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.