Zobrazeno 1 - 10
of 38
pro vyhledávání: '"F.E. Butler"'
Publikováno v:
Journal of the Air Pollution Control Association. 33:968-973
The results are presented from the collaborative test of EPA Method 6-B for the 24-h analysis of SO2, CO2, and emission rate. Using both the intermittent and continuous options of Method 6-B, nine laboratories simultaneously sampled the stack at a fl
Publikováno v:
Journal of the Air Pollution Control Association. 34:936-940
A procedure was developed for the 24-h determination of SO/sub 2/ and CO/sub 2/ in effluent gas from fossil fuel combustion sources. Laboratory experiments were conducted to test absorption of SO/sub 2/ in hydrogen peroxide solution and absorption of
Publikováno v:
Journal of the Air Pollution Control Association. 36:581-584
Techniques were developed to sample and analyze the Cr content of particulate samples with emphasis on determining the concentration of the carcinogen Cr/sup +6/. Cr/sup +6/ is extracted to alkaline solution and analyzed colorimetrically. Residual pa
Publikováno v:
Analytical Chemistry. 58:945-950
Three colorimetric methods for carbon monoxide analysis have been evaluated as potential reference methods for determining the relative accuracy of nondispersive infrared (NDIR) carbon monoxide continuous emissions monitors. The methods are referred
Autor:
F.E. Butler
Publikováno v:
Health Physics. 15:19-24
Autor:
F.E. Butler, E.T. Hippisley
Publikováno v:
Proceedings of the IEE - Part IA: Electric Railway Traction. 97:234-245
The paper reviews present practice and the more recent developments in the design, grouping, and mounting of the control equipment and the auxiliary machines employed on multiple-unit electric trains. It covers only d. c. operation and the rheostatic
Autor:
F.E. Butler
Publikováno v:
Analytical Chemistry. 37:340-342
Autor:
E.T. Hippisley, W.G. Jowett, F.E. Butler, R.I.D. Arthurton, F. Whyman, Richard Brooks, P.L. Mardis, H.R. Broadbent
Publikováno v:
Proceedings of the IEE - Part IA: Electric Railway Traction. 97:296-298
Autor:
F.E. Butler, M.R. Midgett, Sykes Al, Steger Jl, J.E. Knoll, Coppedge Ea, Suggs Jc, Hartman Mw
Publikováno v:
JAPCA. 38(3)
Prior to source sampling, laboratory experiments were conducted to determine the best sample container in which to collect an integrated sample. It was found that CH/sub 2/Cl/sub 2/ remained stable in Tedlar bags for at least four weeks. The analytic
Autor:
F.E. Butler
Radioassays of milk, soil, grass, and other material located near the Savannah River Plant showed no detectable Sr/sup 90/ due to plant wastes. These assays indicated that the Sr/sup 90/ found in this geographical area (25-mile radius of SRP) was nuc
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::44296cd5301df6a947e17a6629e8f244
https://doi.org/10.2172/4170136
https://doi.org/10.2172/4170136