Renewable Energy and Power Quality Journal, 1(10), 44-49. European Association for the Development of Renewable Energies, Environment and Power Quality
The Dutch grid operator Alliander started an ongoing substation refurbishment in 2006 with SASensor, a measurement, protection and control system, including fault localization of persistent faults. Around 20 percent of the recorded measurements compr
Publikováno v:
Journal of Polymer Science Part C: Polymer Symposia. 4:1135-1149
Publikováno v:
IEEE Power Engineering Review, 22(3). Institute of Electrical and Electronics Engineers
IEEE Transactions on Power Delivery, 17(2), 550-554. Institute of Electrical and Electronics Engineers
IEEE Transactions on Power Delivery, 17(2), 550-554. Institute of Electrical and Electronics Engineers
Low-voltage (LV) applications mounted on high-voltage (HV) towers may pose a safety problem in the low voltage network when a flashover occurs over the high-voltage insulators. To study the effects experimentally, a 150 kV system was made available.
Publikováno v:
Proceedings of the 41st International Universities Power Engineering Conference.
The increase of distributed power generation can result in equilibrium of local produced and consumed electrical energy. Power electronics and storage can transform networks in which such equilibrium exists into autonomously controlled networks. Thes
Publikováno v:
2005 International Conference on Future Power Systems.
The increase of distributed generation in the network of Nuon results in challenges for both operation and planning. The load profiles are influenced by the varying amount of distributed generation. This makes the detection of maximum load more compl
Publikováno v:
2005 International Conference on Future Power Systems.
The increase of distributed generation has strong impact on network operation and design. Local equilibrium of load and generation in combination with implementing power electronics and storage opens the possibility for autonomously operating network
Autor:
P. van Oirsouw, F. Provoost
Publikováno v:
2005 International Conference on Future Power Systems.
Economical trends force electricity companies to maximize the utilization of their networks. As a result margins decrease. Within these decreased margins the quality of supply must improve. Disturbances have to be avoided and, if they occur, solved a
Publikováno v:
Proc. Developments in Power System Protection DPSP, Amsterdam, The Netherlands
In our pilot project for refurbishing the 150/10 kV substation Zaltbommel we realized not only state of the art protection and control, but also a fully integrated power quality measurement for all 20 outgoing feeders. Also we realized a medium volta
Autor:
M.J.M. van Riet, A.P.J. van Deursen, F. Provoost, P.C.T. van der Laan, J.F.G. Cobben, J.B.M. van Waes, J. van der Merwe
Publikováno v:
Proceedings of the 2000 IEEE Power Engineering Society Winter Meeting, Singapore, 2385-2390
STARTPAGE=2385;ENDPAGE=2390;TITLE=Proceedings of the 2000 IEEE Power Engineering Society Winter Meeting, Singapore
STARTPAGE=2385;ENDPAGE=2390;TITLE=Proceedings of the 2000 IEEE Power Engineering Society Winter Meeting, Singapore
This paper describes the consequences of a fault in a medium voltage network on the grounding systems at the LV-side. To study the current distribution and to verify the models, we deliberately introduced one phase to ground faults in the 10 kV float
Autor:
F. Provoost, P.M. Van Oirsouw
Publikováno v:
16th International Conference and Exhibition on Electricity Distribution (CIRED 2001).
A new method is developed for low-voltage distribution network design. It enables the electricity distribution companies to calculate more accurately when engineering power distribution networks. The method is based on the calculation of cost-optimal