Zobrazeno 1 - 10
of 25
pro vyhledávání: '"F. Laitano"'
Publikováno v:
Physics in Medicine and Biology. 52:6197-6214
Energy and angular distributions of electron beams with different energies were simulated by Monte Carlo calculations. These beams were generated by the NOVAC7 system (Hitesys, Italy), a mobile electron accelerator specifically dedicated to intra-ope
Publikováno v:
Physics in Medicine and Biology. 51:6419-6436
The correction for charge recombination was determined for different plane-parallel ionization chambers exposed to clinical electron beams with low and high dose per pulse, respectively. The electron energy was nearly the same (about 7 and 9 MeV) for
Autor:
M.K.H. Schneider, D.T. Burns, P.J. Allisy-Roberts, V.Yu. Nagy, Marc F. Desrosiers, Y.L. Zhang, R F Laitano, Peter Sharpe, Kishor Mehta
Publikováno v:
Radiation Physics and Chemistry. 75:1087-1092
Six national standards for absorbed dose to water in 60 Co gamma radiation at the dose levels used in radiation processing have been compared over the range from 5 to 30 kGy using the alanine dosimeters of the NIST and the NPL as the transfer dosimet
"Prototypes of radiation detectors for clinical dosimetry were constructed using commercially available synthetic diamond. Polished diamond plates of detector grade and standard quality were used. The metallization scheme was a typical Ag–Ag contac
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od______3668::24bd803bffb5a93998d88a4825a1b51a
https://hdl.handle.net/11590/278700
https://hdl.handle.net/11590/278700
Autor:
R. F. Laitano
Publikováno v:
La Rivista del Nuovo Cimento. 21:1-58
Publikováno v:
Physics in Medicine and Biology. 40:1177-1190
Dosimetry in radiotherapy with ionization chambers calibrated in 60Co gamma beams in terms of absorbed dose to water, DW, can be performed if a factor conventionally denoted as kQ is known. The factor kQ depends on the beam quality and the chamber ch
Publikováno v:
Physics in Medicine and Biology. 38:39-54
The appropriate correction factors have been determined to enable plane-parallel ionization chambers to be calibrated using a 60Co photon beam with a known air kerma rate. These factors refer to different calibration conditions and to different types
Study of a CVD diamond detector for absorbed dose measurement in photon beams with small field sizes
Publikováno v:
IFMBE Proceedings ISBN: 9783642034725
A new diamond detector to perform absorbed-dose- to-water measurement in radiotherapy photon beams with small field sizes is being developed in the framework of the EURAMET/EC FP7 project “External Beam Cancer Therapy”. An objective of the projec
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5addffa365c4aedd13463282c68f1ed0
https://doi.org/10.1007/978-3-642-03474-9_286
https://doi.org/10.1007/978-3-642-03474-9_286
Publikováno v:
Medical Physics. 18:934-938
Several x‐ray spectra, including those of the ISO reference radiations, were measured by 2‐hp Gedetectors. Measurements were carried out in different experimental conditions with regard to detector size, beam collimation, and SDD. A stripping pro
Autor:
S. Sartori, F. Galliana, C. Ferrero, M. Belli, A. Ferrero, F. Laitano, Leschiutta, Sigfrido, P.G. Zani, Mortarino, Massimo, S. D'Emilio, M. Mosca, Marelli, Clemente, Ciampaglia, Alberto
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::436133fce3b3323cfb15698c9308030b