Zobrazeno 1 - 10
of 33
pro vyhledávání: '"F. J. Salguero"'
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Autor:
Alessia Gasparini, Marcel Verheij, M van de Ven, D. van Berlo, Jan-Jakob Sonke, B.G.J. Floot, N. de Wit, J.-Y. Song, Artem Khmelinskii, Robert P. Coppes, Conchita Vens, F. J. Salguero
Publikováno v:
Radiotherapy and Oncology, 138, 17-24
Radiotherapy and Oncology, 138, 17-24. Elsevier Ireland Ltd
Radiotherapy and oncology
Radiotherapy and Oncology, 138, pp. 17-24
Radiotherapy and Oncology, 138, 17-24. ELSEVIER IRELAND LTD
Radiotherapy and Oncology, 138, 17-24. Elsevier Ireland Ltd
Radiotherapy and oncology
Radiotherapy and Oncology, 138, pp. 17-24
Radiotherapy and Oncology, 138, 17-24. ELSEVIER IRELAND LTD
Background and purpose: Preclinical models are much needed to assess the effect of novel radiosensitizers or mitigators on radiation dose limiting lung toxicity. Albeit showing radiation-induced lung pathologies, current mouse models lack the sensiti
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5dcadcdb910743c32e217c32367ecd0f
http://hdl.handle.net/2066/208670
http://hdl.handle.net/2066/208670
Publikováno v:
RUA. Repositorio Institucional de la Universidad de Alicante
Universidad de Alicante (UA)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
instname
Universidad de Alicante (UA)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
instname
Water distribution systems are made up of many interdependent elements that enable water supply to meet a demand that is variable in time and space. One of the main concerns for utility managers is quickly locating and repairing a leak after detectio
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::439697d1dbdd4d7d46f38a5e95ce0ac9
https://hdl.handle.net/10045/87167
https://hdl.handle.net/10045/87167
Autor:
F. J. Salguero
Publikováno v:
Bovine tuberculosis
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::45b270b9c4071eff19097c3030aa3d57
https://doi.org/10.1079/9781786391520.0122
https://doi.org/10.1079/9781786391520.0122
Publikováno v:
Medical physics. 39(6Part18)
Purpose: To quantify dose mapping errors (DMEs) of a point‐based dose mapping method for 4D lung treatment plans. Methods: Point‐based dose mapping methods utilize deformation vector fields (DVFS) to interpolate dose from a deformed image. Volume
Autor:
Elisabeth Weiss, N Saleh-Sayah, C Yan, Jeffrey V. Siebers, William C. Sleeman, F. J. Salguero, Geoffrey D. Hugo
Publikováno v:
Medical Physics. 39:2119-2128
Purpose: To present a method to evaluate the dose mapping error introduced by the dose mapping process. In addition, apply the method to evaluate the dose mapping error introduced by the 4D dose calculation process implemented in a research version o
Autor:
F. J. Salguero, Amadeo Wals Zurita, Rafael Arráns, Antonio Leal, Ana Ureba Sánchez, Carlos Míguez Sánchez, B. Palma, María Isabel Romero Hermida
Publikováno v:
Physics in Medicine and Biology. 57:1191-1202
The purpose of this study was to present a Monte-Carlo (MC)-based optimization procedure to improve conventional treatment plans for accelerated partial breast irradiation (APBI) using modulated electron beams alone or combined with modulated photon
A method to estimate the effect of deformable image registration uncertainties on daily dose mapping
Publikováno v:
Medical Physics. 39:573-580
Purpose: To develop a statistical sampling procedure for spatially-correlated uncertainties in deformable image registration and then use it to demonstrate their effect on daily dose mapping. Methods: Sequential daily CT studies are acquired to map a
Publikováno v:
Medical Physics. 38:2318-2323
Purpose : To introduce a tool, termed distance to dose difference (DTD), which estimates the required spatial accuracy of displacement vector fields (DVFs) used for mapping four dimensional dose values. Methods : Dose mapping maps dose values from an
Publikováno v:
Medical Physics. 38:343-353
Purpose: This article presents a general procedural framework to assess the point-by-point precision in mapped dose associated with the intrinsic uncertainty of a deformable image registration (DIR) for any arbitrary patient. Methods: Dose uncertaint