Zobrazeno 1 - 10
of 39
pro vyhledávání: '"F. Cannillo"'
Autor:
Alonso Morgado, Chris Van Hoof, Serena Porrazzo, David San Segundo Bello, Arthur van Roermund, F. Cannillo, Refet Firat Yazicioglu, Eugenio Cantatore
Publikováno v:
IEEE Transactions on Biomedical Circuits and Systems. 7:573-582
This paper presents a low-power switched-capacitor ΔΣ modulator for digital hearing-aid applications that features a novel summing successive approximation (SAR). The summing SAR performs multi-bit quantization together with the analog addition req
Publikováno v:
IEEE Transactions on Instrumentation and Measurement, 61(11), 2896-2904. Institute of Electrical and Electronics Engineers
In this paper, a methodology for the power-optimal design of high-resolution low-bandwidth switched-capacitor $DeltaSigma$ modulators ($ DeltaSigmahbox{Ms}$) is presented. The most power-efficient $ DeltaSigma$ architecture is identified among single
Publikováno v:
IEEE Transactions on Circuits and Systems I: Regular Papers. 56:1598-1611
This paper presents subthreshold MOS current-mode logic (MCML) circuits implemented in a commercial 0.25-mum CMOS technology. We propose the adoption of bulk-drain-connected pMOS transistors as loads for subthreshold MCML gates. The b-d connection ex
Autor:
C. Toumazou, F. Cannillo
Publikováno v:
IEEE Transactions on Circuits and Systems I: Regular Papers. 56:1576-1589
Single and parallel subthreshold frequency-modulation-to-digital Delta-Sigma modulators (FDSMs) have been implemented in a standard 90-nm CMOS technology. Theoretical and measured results are presented for both topologies. The 512-stage parallel FDSM
Autor:
A. M. Cesinaro, Caterina Longo, Tarl W. Prow, Elisa Benati, Alice Casari, F. Cannillo, Giuseppe Argenziano, Martina Ulrich, Giovanni Pellacani, A. Losi, Hans Peter Soyer
Background: Actinic Keratosis (AK) is the clinical manifestation of cutaneous dysplasia of epidermal keratinocytes, withprogressive trend towards squamous cell carcinoma. Objective: To evaluate the strength of the correlation between keratinocyte aty
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0a3c4556c41fc3cf5226cf6216ee521b
https://hdl.handle.net/11541.2/126069
https://hdl.handle.net/11541.2/126069
Autor:
Leopoldo Conte, G. Leo, Alexander Dierlamm, W. Kucewicz, Matteo Amati, W. Dulinski, Luigi P. Badano, C. Colledani, Y. Popowski, L. Jungermann, M. Sapor, B. Dulny, J.L. Riester, W. De Boer, Jacek Marczewski, H. Niemiec, H. Bol, Daniel Tomaszewski, Grzegorz Deptuch, L. Paolucci, A. Airoldi, B. Spanò, C. Cappellini, A. Zalewska, C. Bianchi, Witold Machowski, Piotr Grabiec, M. Alemi, Raffaele Novario, S. Kuta, M. Cacciaa, R. Lorusso, A. Czermak, M. Pezzetta, Krzysztof Domański, Krzysztof Kucharski, O. Ferrando, D. Berst, G. Mondry, E. Grigoriev, H. Schweickert, C. Sampietro, Antonio Bulgheroni, B. Jaroszewicz, V. Bartsch, G. Claus, F. Cannillo
Publikováno v:
Nuclear Physics B - Proceedings Supplements. 125:133-138
SUCIMA (Silicon Ultra fast Cameras for electron and γ sources In Medical Applications) is a project approved by the European Commission with the primary goal of developing a real time dosimeter based on direct detection in a Silicon substrate. The m
Autor:
A.H.M. van Roermund, Alonso Morgado, F. Cannillo, David San Segundo Bello, Serena Porrazzo, Eugenio Cantatore, C. Van Hoof
Publikováno v:
BioCAS
In this paper we present a low-power switched-capacitor ΔΣ modulator for digital hearing-aid applications. The circuit adopts a novel summing successive approximation (SAR) block to perform multi-bit quantization together with the analog addition t
Publikováno v:
ESSCIRC
High-resolution Sigma-Delta (∑Δ) ADCs are increasingly used in portable medical applications for the measurement of biopotential signals. This paper presents the implementation and measurements of a novel ultra-low power low voltage multi-bit cont
Publikováno v:
Proceedings of 2010 International Symposium on VLSI Design, Automation and Test.
An ultra low-power fast charge preamplifier implemented in 0.35µm CMOS technology for ion detector readout for space operation is presented. For a 10pF sensor capacitance, the preamplifier achieves a peaking time of 4.5ns and pulse-pair resolution (