Zobrazeno 1 - 7
of 7
pro vyhledávání: '"Esra Al Hosani"'
Publikováno v:
IEEE Photonics Journal, Vol 8, Iss 3, Pp 1-15 (2016)
This paper suggests a new near-infrared (NIR)-based device to accurately measure the concentration of solid contaminants passing through gas-oil pipelines. It consists of a ring of NIR sources and receivers, which are evenly distributed across a cros
Externí odkaz:
https://doaj.org/article/f5e888c08834481897630cebd911f211
Publikováno v:
IEEE Transactions on Terahertz Science and Technology. 8:418-426
In this paper, a new FPGA-based terahertz (THz) imaging device for real-time multiphase flow metering is proposed. The probe comprises a THz source and a 64 × 64 THz camera in which a stainless steel-flanged teflon-made cylindrical probe is used. A
Online and reliable monitoring of steam quality in power plants is of great importance in smart grids today since it can mitigate eventual erosions and buildups which may occur in associated metal equipment such as pipes and steam turbine. This in tu
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::7f738074676f5cf9a82c7a978d727385
https://doi.org/10.4018/978-1-5225-5510-0.ch009
https://doi.org/10.4018/978-1-5225-5510-0.ch009
Publikováno v:
ICDCS Workshops
This paper presents a hybrid device for real-time measurement and imaging of solid and liquid contaminants that may occur in steam generators. The device uses a dedicated Near Infra-Red device to determine the type of contaminants and a THz imaging s
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 63:2238-2252
In this paper, an optical-based device for online black powder detection in gas pipelines is proposed. The device uses different optical wavelengths within the infrared (IR) range and applies chemometric algorithms to quantify the actual amount of bl
Publikováno v:
Day 2 Tue, November 08, 2016.
In this paper, a new FPGA-based THz imaging device for real-time multiphase flow metering is proposed. The overall system consists of a THz source and a THz camera within which a stainless steel-flanged Teflon-made cylindrical probe is provided to ca
Publikováno v:
Al Hosani, E, Zhang, M & Soleimani, M 2015, ' A limited region electrical capacitance tomography for detection of deposits in pipelines ', IEEE Sensors Journal, vol. 15, no. 11, pp. 6089-6099 . https://doi.org/10.1109/JSEN.2015.2453361
Pipeline deposit is a worldwide problem facing the process industry affecting all phases of production, transmission, and distribution causing problems to the pipeline operations up to the customer delivery point. Therefore, monitoring the propagatio
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::841e0903688be26e846e78ba25398b26
https://purehost.bath.ac.uk/ws/files/132211356/susu_maomao.pdf
https://purehost.bath.ac.uk/ws/files/132211356/susu_maomao.pdf